ELR H5-IES-SC- 24DC/500AC-9 2900421 PHOENIX CONTACT Hybrid motor starter for reversing 3~ AC motors up to 50.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

ELR H5-IES-SC- 24DC/500AC-9 2900421 PHOENIX CONTACT Hybrid motor starter for reversing 3~ AC motors up to 50..

ELR H5-IES-SC- 24DC/500AC-9

2900421

PHOENIX_CONTACT

Available

Ship on today

Hybrid motor starter for reversing 3~ AC motors up to 500 V AC and 9 A output current, with 24 V DC control voltage, adjustable overload shutdown, emergency stop function to SIL 3/PL e, and screw connection.

More details


Programmable Logic Controllers Plcs

INTERFACE Signal converters, switching devices, and power supply units - PHOENIX CONTACT

Solid state relays and power electronics. Relay - PHOENIX CONTACT

* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

Quantity Price
1+$165.33
2+$159.63
3+$156.90
4+$155.19
6+$153.47
*This price is per unit and is the net value (not including taxes if applicable).

Related products

More info



Input data

Input nameDevice supply
Rated control circuit supply voltage US24 V DC
Rated control supply current IS40 mA
Protective circuitProtection against polarity reversal Parallel polarity protection diode
Surge protection
Operating voltage displayGreen LED
Status displayYellow LED
IndicationRed LED
Input nameControl input right/left
Rated actuating voltage UC24 V DC
Rated actuating current IC5 mA
Switching threshold9.6 V (“0” signal)
19.2 V (“1” signal)
Switching level< 5 V DC (For EMERGENCY STOP)
Protective circuitProtection against polarity reversal
Typical turn-off time< 30 ms

Output data load output

Rated operating voltage Ue500 V AC
Operating voltage range42 V AC ... 550 V AC
Load current range1.5 A ... 9 A (see to derating)
Trigger characteristic in acc. with IEC 60947Class 10A
Rated operating current at AC-519 A
Rated operating current at AC-53a6.5 A
Leakage current0 mA
Protective circuitSurge protection Varistor

Output data reply output

NoteConfirmation: floating change-over contact, signal contact
Contact type1 PDT

Connection data, control circuit

Connection nameControl circuits
Connection methodScrew connection
Stripping length8 mm
Screw threadM3
Conductor cross section solid0.2 mm² ... 2.5 mm²
Conductor cross section flexible0.2 mm² ... 2.5 mm²
Conductor cross section AWG24 ... 14
Torque0.5 Nm ... 0.6 Nm

General

Switching frequency≤ 2 Hz (Load-dependent)
Mounting positionvertical (horizontal DIN rail, motor output below)
Assembly instructionsalignable, for spacing see derating
Operating mode100% operating factor
DesignationStandards/regulations
Standards/regulationsIEC 60947-1
EN 60947-4-2
IEC 61508
ISO 13849
Safety Integrity Level according to IEC 61508SIL 3 (safe shutdown)
SIL 2 (motor protection)
Category acc. to EN ISO 138493 (Safe shutdown)
Performance level according to ISO 13849e (Safe shutdown)

Dimensions

Width22.5 mm
Height99 mm
Depth114.5 mm

Ambient conditions

Ambient temperature (operation)-25 °C ... 70 °C (observe derating)
Ambient temperature (storage/transport)-40 °C ... 80 °C
Degree of protectionIP20

Datasheet - PDF

Title: Language: Size: Type:
PHOENIX CONTACT-2900421-ELR H5-IES-SC- 24DC/500AC-9 English 153 Kbytes PHOENIX CONTACT-2900421-ELR H5-IES-SC- 24DC/500AC-9

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

Últimas Opiniones de Nuestros Clientes

Todas las valoraciones que recibimos de los artículos que ofrecemos son reales y están verificadas. Un pequeño gesto, pero de mucho valor. Por eso, te agradecemos ese minuto que inviertes en dejarnos tu opinión y calificación sobre los productos, porque nos ayuda a seguir mejorando y a ofrecerte un servicio de todavía mayor calidad.