Combination of type 2 surge protection and arrester pre-fuse, with monitoring of the discharger and pre-fuse, in combination with status indication and remote indication contact. Implementation: 4-conductor system (L1, L2, L3, PEN), NS 35 carrier rail mounting

Combination of type 2 surge protection and arrester backup fuse, with monitoring of arrester and arrester backup fuse, in combination with a status indicator and remote indication contact. Design: 4-conductor system (L1, L2, L3, PEN), mounting on NS 35 DIN rail

More details


Earthing, lightning and surge protection > Surge protection device for power supply systems

Trabtech (TT)

Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

Total: $429.67
Unit price: $429.67
This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



Technical data

Product properties
Product typeSurge arrester
Product familySEC Family
IEC test classificationII
T2
EN typeT2
IEC power supply systemTN-C
TypeDIN rail module, two-section, divisible
Number of positions3
Surge protection fault messageOptical, remote indicator contact
Data management status
Article revision11
Insulation characteristics
Overvoltage categoryIII
Pollution degree2

Electrical properties
Nominal frequency fN50 Hz (60 Hz)
Indicator/remote signaling
Connection nameRemote fault indicator contact
Switching functionChangeover contact
Operating voltage250 V AC
250 V DC
Operating current1 mA AC ... 2 A AC
1 mA DC ... 50 mA DC

Connection data
Connection protective circuit
Connection methodScrew connection
Tightening torque3.5 Nm
Stripping length14 mm
Conductor cross section flexible4 mm² ... 25 mm²
Conductor cross section rigid4 mm² ... 35 mm²
Conductor cross section AWG18 ... 2
Protective ground connection
Connection methodScrew connection
Screw threadM5
Tightening torque4.5 Nm
Stripping length16 mm
Conductor cross section flexible2.5 mm² ... 16 mm²
Conductor cross section rigid2.5 mm² ... 25 mm²
Conductor cross section AWG12 ... 4
Remote fault indicator contact
Connection methodPluggable screw connection
Screw threadM2
Tightening torque0.25 Nm
Stripping length7 mm
Conductor cross section flexible0.14 mm² ... 1.5 mm²
Conductor cross section rigid0.14 mm² ... 1.5 mm²
Conductor cross section AWG28 ... 16

Dimensions
Dimensional drawingezrhhnabdp.jpg
Width114 mm
Height101 mm
Depth76 mm
Horizontal pitch6.5 Div.

Material specifications
Colorlight gray (RAL 7035)
black (RAL 9005)
Flammability rating according to UL 94V-0
CTI value of material600
Insulating materialPBT-FR
Material groupI
Housing materialPBT-FR

Protective circuit
Mode of protectionL-PEN
Direction of action3L-N/PE
Nominal voltage UN240/415 V AC (TN-C)
Nominal frequency fN50 Hz (60 Hz)
Maximum continuous voltage UC350 V AC
Nominal discharge current In(8/20) µs15 kA
Maximum discharge current Imax(8/20) µs30 kA
Short-circuit current rating ISCCR25 kA
Voltage protection level Up≤ 2.5 kV
Residual voltage Ures≤ 2.3 kV (at In)
≤ 1.6 kV (at 10 kA)
≤ 1.3 kV (at 5 kA)
≤ 1 kV (at 3 kA)
TOV behavior at UT415 V AC (5 s / withstand mode)
457 V AC (120 min / safe failure mode)
Response time tA≤ 25 ns
Max. backup fuse with V-type through wiring40 A (gG)

Environmental and real-life conditions
Ambient conditions
Degree of protectionIP20
Ambient temperature (operation)-25 °C ... 60 °C
Ambient temperature (storage/transport)-40 °C ... 80 °C
Altitude≤ 2000 m (amsl)
Permissible humidity (operation)5 % ... 95 %

Standards and regulations
Standards/specificationsIEC 61643-11
Note2011
Standards/specificationsEN 61643-11
Note2012
Standards/specificationsIEC 60364-4-443
Standards/specificationsIEC 60364-5-534

Mounting
Mounting typeDIN rail: 35 mm

ETIM for 2882776 Earthing, lightning and surge protection (EC000941)
Feature Name Feature Value
System configuration DC (EF009926) No
System configuration IT (EF009927) No
System configuration TN (EF009928) No
System configuration TN-C (EF009929) Yes
System configuration TN-C-S (EF009933) No
System configuration TN-S (EF009930) No
System configuration TT (EF009931) No
System configuration other (EF009932) No
Nominal discharge surge current (8/20) (EF004214) 15 kA
Max. discharge surge current (8/20) (EF012274) 30 kA
Max. continuous voltage AC (EF004198) 350 V
Voltage protection level L-N (EF004236) 2.5 kV
Max. overcurrent protection device, series connection (fuse) (EF015963) 40 A
Short-circuit breaking capacity (Isccr) (EF012627) 25 kA
Integrated backup fuse (EF008797) Yes
Leakage-current free (EF016002) No
Mounting method (EF000003) DIN rail (top hat rail) 35 mm
Construction size (EF002566) Other
Max. conductor cross section solid (solid, stranded) (EF008827) 4 mm²
Max. conductor cross section flexible (fine-strand) (EF008828) 25 mm²
With remote signalling contact (EF000422) Yes
Signalling at the device (EF004241) Optic
Category type 2 (EF004230) Yes
Degree of protection (IP) (EF005474) IP20

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.