HG-S1110-AC PANASONIC HG-S Sensor for measurement by contact. Head sensor with pneumatic actuator. Resolutio..

HG-S1110-AC

PANASONIC

HG-S - Sensor for measurement by contact. Head sensor with pneumatic actuator. Resolution to 0.1 µm. Accuracy 1µm. Range 10mm

HG-S1110-AC_Contact-Type Digital Displacement Sensor_Contact-Type Digital Displacement Sensor HG-S_Air-driven type 10 mm 0.394 in type High precision

More details


Laser Sensors - Spot Type - AN - PANASONIC

* Brand new product in its original packaging covered by the warranties and certifications provided by PANASONIC

* This article is restricted. Please ask us for a quotation and we will check if there are units available or we will offer you an alternative product.

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



Product NumberHG-S1110-AC
Part NumberHG-S1110-AC
ProductContact-Type Digital Displacement Sensor
DetailsAir-driven type
10 mm 0.394 in type High precision
Product nameContact-Type Digital Displacement Sensor HG-S

ItemSpecifications
Product NumberHG-S1110-AC
Part NumberHG-S1110-AC
Regulatory complianceEMC Directive, RoHS Directive
Applicable controllerHG-SC101(-P), HG-SC111(-P), HG-SC112(-P), HG-SC113
(Note) : Be sure to use the sensor in combination with an HG-SC□ controller manufactured in or after February 2019.
Position detection methodOptical absolute linear encoder method
Measuring range10 mm 0.394 in
(Note) : The position that represents "0" as an absolute value is a position where the spindle is pushed further down from the bottom dead point by 0.1 mm 0.004 in or more. The term "stroke" indicates the total stroke length from the bottom dead point to the top dead point.
Stroke10.5 mm 0.413 in or more
(Note) : The position that represents "0" as an absolute value is a position where the spindle is pushed further down from the bottom dead point by 0.1 mm 0.004 in or more. The term "stroke" indicates the total stroke length from the bottom dead point to the top dead point.
Measuring force・Measuring force changes with the air pressure used. Removing the seal cap enables the product to be used as the low measuring force type.
・For the relationship between supplied air pressure and measuring force or between measuring force and pushed spindle position, see the figures below. For upward mount without a seal cap, subtract 0.2 N from the measuring force. For side mount, subtract 0.1 N from the measuring force. The following figures are only typical examples, and these relationships differ depending on the assembly accuracy of the product or the abrasion status of sealing materials.
the relationship between supplied air pressure and measuring force or between measuring force and pushed spindle position
Resolution0.1 μm 0.004 mil
Sampling rate1 ms
Indication accuracy(P-P)Full range: 1.0 μm 0.039 mil or less
Limited range: 0.5 μm 0.02 mil or less
(any 60 μm 2.362 mil)
Tip deviation amount35 μm 1.378 mil (typical value)
Hot swap functionIncorporated
Working pressure range0.14 to 0.16 MPa
With no seal cap mounted : 0.035 to 0.045 MPa
Capacity to resist pressure0.2 MPa
Usable fluidClean air (Dew point temperature: -10 ℃ +14 ℉ or less)
Applicable tubeOutside diameter: ø4 mm ø0.157 in / Inside diameter: ø2.5 mm ø0.098 in
Operation indicatorEquipped (2-color LED: Orange / Green)
Pollution degree2
Operating altitude2,000 m 6561.68 ft or less
(Note) : Do not use or store in an environment that has been pressurized to an air pressure higher than the atmospheric pressure at 0 m.
Environmental resistance : ProtectionIP67 (IEC)
With no seal cap mounted : -
(Note) : Protective structure is not applicable when the sealing portions have deteriorated or become damaged. The protection level is zero when the seal cap is removed.
Environmental resistance : Ambient temperature-10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed),
Storage: -20 to +60 ℃ -4 to +140 ℉
Environmental resistance : Ambient humidity35 to 85 % RH, Storage: 35 to 85 % RH
Insulation resistance100 MΩ or more at 250 V DC
Environmental resistance : Vibration resistance10 to 500 Hz frequency, 3 mm 0.118 in double amplitude (10 to 58 Hz), maximum acceleration 196 m/s2, (58 to 150 Hz) in X, Y, and Z directions for two hours each
Environmental resistance : Shock resistance1,960 m/s2 acceleration in X, Y, and Z directions three times each
Grounding methodCapacitor grounding
MaterialBody: Zinc, Holder: Stainless steel, Spindle: Tool steel, Probe (Note): Brass (body) / Ceramic (ball),, Air tube clamp: S60CM
(Note) : The probe is also available as an option.
WeightNet weight: 80 g approx.
AccessorySensor head fastening wrench: 1 pc., Mounting nut: 1 pc., Seal cap: 1pc, Air tube clamp: 1 pc.
RemarkWhere measurement conditions are not specified, the conditions used were as follows: standard type measurement probe (HG-SS10C), ambient temperature of +20 ℃ +68 ℉, and a clean atmosphere where water, oil, other liquids or dust does not come in contact with the equipment.

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.