Product successfully added to your shopping cart
HG-S1110-AC
PANASONIC
1
HG-S - Sensor for measurement by contact. Head sensor with pneumatic actuator. Resolution to 0.1 µm. Accuracy 1µm. Range 10mm
HG-S1110-AC_Contact-Type Digital Displacement Sensor_Contact-Type Digital Displacement Sensor HG-S_Air-driven type 10 mm 0.394 in type High precision
Laser Sensors - Spot Type - AN - PANASONIC
* Brand new product in its original packaging covered by the warranties and certifications provided by PANASONIC
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
Product Number | HG-S1110-AC |
Part Number | HG-S1110-AC |
Product | Contact-Type Digital Displacement Sensor |
Details | Air-driven type 10 mm 0.394 in type High precision |
Product name | Contact-Type Digital Displacement Sensor HG-S |
Item | Specifications |
---|---|
Product Number | HG-S1110-AC |
Part Number | HG-S1110-AC |
Regulatory compliance | EMC Directive, RoHS Directive |
Applicable controller | HG-SC101(-P), HG-SC111(-P), HG-SC112(-P), HG-SC113 (Note) : Be sure to use the sensor in combination with an HG-SC□ controller manufactured in or after February 2019. |
Position detection method | Optical absolute linear encoder method |
Measuring range | 10 mm 0.394 in (Note) : The position that represents "0" as an absolute value is a position where the spindle is pushed further down from the bottom dead point by 0.1 mm 0.004 in or more. The term "stroke" indicates the total stroke length from the bottom dead point to the top dead point. |
Stroke | 10.5 mm 0.413 in or more (Note) : The position that represents "0" as an absolute value is a position where the spindle is pushed further down from the bottom dead point by 0.1 mm 0.004 in or more. The term "stroke" indicates the total stroke length from the bottom dead point to the top dead point. |
Measuring force | ・Measuring force changes with the air pressure used. Removing the seal cap enables the product to be used as the low measuring force type. ・For the relationship between supplied air pressure and measuring force or between measuring force and pushed spindle position, see the figures below. For upward mount without a seal cap, subtract 0.2 N from the measuring force. For side mount, subtract 0.1 N from the measuring force. The following figures are only typical examples, and these relationships differ depending on the assembly accuracy of the product or the abrasion status of sealing materials. |
Resolution | 0.1 μm 0.004 mil |
Sampling rate | 1 ms |
Indication accuracy(P-P) | Full range: 1.0 μm 0.039 mil or less Limited range: 0.5 μm 0.02 mil or less (any 60 μm 2.362 mil) |
Tip deviation amount | 35 μm 1.378 mil (typical value) |
Hot swap function | Incorporated |
Working pressure range | 0.14 to 0.16 MPa With no seal cap mounted : 0.035 to 0.045 MPa |
Capacity to resist pressure | 0.2 MPa |
Usable fluid | Clean air (Dew point temperature: -10 ℃ +14 ℉ or less) |
Applicable tube | Outside diameter: ø4 mm ø0.157 in / Inside diameter: ø2.5 mm ø0.098 in |
Operation indicator | Equipped (2-color LED: Orange / Green) |
Pollution degree | 2 |
Operating altitude | 2,000 m 6561.68 ft or less (Note) : Do not use or store in an environment that has been pressurized to an air pressure higher than the atmospheric pressure at 0 m. |
Environmental resistance : Protection | IP67 (IEC) With no seal cap mounted : - (Note) : Protective structure is not applicable when the sealing portions have deteriorated or become damaged. The protection level is zero when the seal cap is removed. |
Environmental resistance : Ambient temperature | -10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: -20 to +60 ℃ -4 to +140 ℉ |
Environmental resistance : Ambient humidity | 35 to 85 % RH, Storage: 35 to 85 % RH |
Insulation resistance | 100 MΩ or more at 250 V DC |
Environmental resistance : Vibration resistance | 10 to 500 Hz frequency, 3 mm 0.118 in double amplitude (10 to 58 Hz), maximum acceleration 196 m/s2, (58 to 150 Hz) in X, Y, and Z directions for two hours each |
Environmental resistance : Shock resistance | 1,960 m/s2 acceleration in X, Y, and Z directions three times each |
Grounding method | Capacitor grounding |
Material | Body: Zinc, Holder: Stainless steel, Spindle: Tool steel, Probe (Note): Brass (body) / Ceramic (ball),, Air tube clamp: S60CM (Note) : The probe is also available as an option. |
Weight | Net weight: 80 g approx. |
Accessory | Sensor head fastening wrench: 1 pc., Mounting nut: 1 pc., Seal cap: 1pc, Air tube clamp: 1 pc. |
Remark | Where measurement conditions are not specified, the conditions used were as follows: standard type measurement probe (HG-SS10C), ambient temperature of +20 ℃ +68 ℉, and a clean atmosphere where water, oil, other liquids or dust does not come in contact with the equipment. |
Title: | Size: | Type: |
---|---|---|
PDF CATALOG PANASONIC SENSORS EN.pdf | 31 Mbytes | |
Download general catalog |
No customer reviews for the moment.
Rating: | |
Name: | |
Email: | |
Subject: | |
Text: | |
Do you recommend this product to buy? | |
Add review |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.