ZX-XBE2 143639 OMRON Advanced sensors, preamplifier mounting bracket DIN rail View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

ZX-XBE2 143639 OMRON Advanced sensors, preamplifier mounting bracket DIN rail

ZX-XBE2

143639

OMRON

Available

Ship on today

Advanced sensors, preamplifier mounting bracket DIN rail

More details


Monitoring Products Measurement

Accessories Advanced Sensors

* Brand new product in its original packaging covered by the warranties and certifications provided by OMRON

Quantity Price
1+$52.96
4+$47.98
7+$46.58
10+$45.82
13+$45.37
*This price is per unit and is the net value (not including taxes if applicable).

Related products

More info



ZX-EInductivedisplacement sensor
Smart inductive measurement sensor
ZX-E offers the best solution for the accurate measurementof metallic objects. It is
highly recommended in harsh environments such as automotive and metal working machines.
• High resolution of 1 μm
• High-speed response time of 150 μs
• Easy sensor headreplacement
• Modular platform concept for different sensing technologies
• Easy linearity adjustmentfor any metal
Ordering information
Sensors
Sensor heads
Shape DimensionsSensing distance Resolution*1
Order code
Cylindrical3 dia. × 18 mm 0.5 mm1m ZX-EDR5T
5.4 dia. × 18 mm1 mm ZX-ED01T*2
8 dia. × 22 mm 2 mm ZX-ED02T*2
Screw-shapedM10×22 mm2 mm ZX-EM02T*2
M18×46.3 mm 7 mm ZX-EM07MT*2
Flat30×14×4.8 mm4 mm ZX-EV04T*2,*3
Heat-resistant, cylindricalM12×22 mm2 mm ZX-EM02HT*4
*1For an average count of 4,096.
*2Models with protective spiral tubes are also available. Add a suffix of “-S” to the above model numbers when ordering. (Example: ZX-ED01T-S)
*3Be sure to use ZX-EDA amplifier unit version 1,200 or later with the ZX-EV04.
*4Be sure to use ZX-EDA amplifier unit version 1,300 or later with the ZX-EM02H.
Amplifier units
Power supplyOutput typeOrder code
DC NPNZX-EDA11
PNPZX-EDA41
Note:Compatible connection with the sensor head.
Accessories (order separately)
Calculating unit
Model
SmartMonitor sensor setup tool for Personal Computer connection
NameModel
Calculating unitZX-CAL2
ZX-series communications interface unitZX-SF11
Amplifier mounting brackets
ZX-series communications interface unit
+ setup software (CD-ROM)
ZX-SFW11EV3*1
RemarksModel
Attached to each sensor head ZX-XBE1
For DIN trackmountingZX-XBE2
ZX-series sensor setup and loggingsoftware(CD-ROM) ZX-SW11EV3
*1The ZX-SFW11EV3 SmartMonitor can be used only to set functions and monitor wave- forms.
Cables with connectors on both ends (for extension)*
Cable lengthModel
1 mZX-XC1A
4 mZX-XC4A
8 mZX-XC8A
Specifications
*Robot cable models are also available. The model numbers are ZX-XC_R.
Sensor heads
ItemZX-EDR5T ZX-ED01TZX-ED02T/EM02TZX-EM07MTZX-EV04TZX-EM02HT Measurement range0 to 0.5 mm0 to 1 mm 0 to 2 mm 0 to 7 mm 0 to 4 mm 0 to 2 mm Sensing objectMagnetic metals
(Measurement ranges and linearities are different for non-magnetic metals. Refer to engineering data on B-67.)
Standard reference object18 × 18 × 3 mm30 × 30 × 3 mm60 × 60 × 3 mm45 × 45 × 3 mm
Material: Ferrous (S50C)
Resolution*11 μm
Linearity*2 0.5% F.S. 1% F.S.*3
Linear output rangeSame as measurement range.
Temperature characteristic*4
(including amplifier unit)
0.15% F.S./C 0.07% F.S./C 0.1% F.S./C
Ambient
Operating*5 0 to 50C (with no icing –10 to 60°C (with no icing or condensation)–10 to 200°C
temperature Storage*5
or condensation)
–20 to 70°C (with no icing or condensation)–20 to 200°C
389
ZX-E Inductivedisplacement sensor
ItemZX-EDR5T ZX-ED01TZX-ED02T/EM02TZX-EM07MTZX-EV04TZX-EM02HT Ambient humidityOperating and storage: 35% to 85% (with no condensation)
Insulation resistance 50 M min. (at 500 DC)
Dielectric strength 1,000 VAC, 50/60 Hz for 1 min between charged parts and case
Vibration resistance (destruction)10 to 55 Hz with 1.5-mm double amplitude for 2 h each in X, Y, and Z directions
Shock resistance (destruction)500 m/s2, 3 times each in X, Y, and Z directions
Degree of protection (sensor head)IEC60529, IP65 IEC60529, IP67 IEC60529, IP60*6
Connection methodConnector relay (standard cable length: 2 m)
Weight (packed state) Approx. 120 g Approx. 140 g Approx. 160 g Approx. 130 g Approx. 160 g
Materials Sensor head Case BrassStainless steelBrassZinc (nickel-plated) Brass
Sensing surface
Heat-resistantABSPEEK
Preamplifier PES
AccessoriesAmplifier mounting brackets (ZX-XBE1), instruction manual
*1Accuracy: The resolutionis the deviation (3) in the linear output when connected to the ZX-EDA amplifier unit. The above values indicate the deviations observed 30 minutes after the power is turned ON.
(The resolution is measured with Omron's standard reference object at ½ of the measurement range with the ZX-EDA set for the maximum average count of 4,096 per period.)
The resolution is given at the repeat accuracy for a stationary workpiece, and is not an indication of the distance accuracy. The resolution may be adversely affected under strong electromag- netic fields.
*2Linearity: The linearity is given as the error in an ideal straight line displacement output when measuring the standard reference object. The linearity and measurement values vary with the object being measured.
*3The value given is for an ambient temperature of 25°C.
*4Temperature characteristic: The temperature characteristic is measured with Omron's standard reference object at ½ of the measurement range.
*5The ambient temperature given is only for the sensor head. It is -10 to 60°C for the preamp.
*6Do not use in moist environments because the case is not waterproof.
Amplifier units
ItemZX-EDA11ZX-EDA41
Measurement period150 μs
Possible average count settings*1
Linear output*2
Judgement outputs
(3 outputs: HIGH/PASS/LOW)
1, 2, 4, 8, 16, 32, 64, 128, 256, 512, 1,024, 2,048, or 4,096
Current output: 4 to 20 mA/F.S., max. load resistance: 300
Voltage output: ±4 V (±5 V, 1 to 5 V *3), output impedance: 100 
NPN open-collector outputs, 30 VDC, 50 mA max. Residual voltage: 1.2 V max.
PNP open-collector outputs, 30 VDC, 50 mA max. Residual voltage: 2 V max.
Zero reset input, timing input, reset input,ON:Short-circuited with 0-V terminal or 1.5 V or less
ON:Supply voltage short-circuited or supply voltage within 1.5 V
judgement output hold input
OFF:Open (leakage current: 0.1 mA max.)
OFF:Open (leakage current: 0.1 mA max.)
Function – Measurement value display – set value/output value/
– Linearity adjustment (materials selection)resolution display – Scaling
– Display reverse– displayOFF mode – ECO mode
– Number of display digit changes– sample hold – peak hold
– Bottom hold, peak-to-peak hold – self-peak hold– self-bottom hold
– Average hold – delay hold– zero reset
– Initial reset – linearity initialization– ON-delay timer
– OFF-delay timer – one-shot timer– previous value comparison
– Non-measurement setting – direct threshold value setting – position teaching
– Automatic teaching – hysteresis width setting– timing inputs
– Reset input – judgement output hold input – monitor focus
– Linear output correction– (A-B) calculations*4 – (A+B) calculations*4
– K-(A+B) calculation*4– mutual interference prevention*4
– Sensor disconnection detection – zero reset memory – zero reset indicator
– Key lock
IndicationsJudgement indicators: High (orange), pass (green), low (yellow), 7-segment main digital display (red),
7-segment sub-digital display (yellow), power ON (green),zero reset (green), enable (green)
Voltage influence
(including sensor)
0.5% F.S. of linearoutput value at 20% of power supply voltage
Power supply voltage 12 to 24 VDC10%, ripple (p-p): 10% max.
Current consumption140 mA max. with power supply voltage of 24 VDC (with sensor connected)
Ambient temperatureOperating and storage: 0to 50C (with no icing or condensation) Ambient humidityOperating and storage: 35% to 85% (with no condensation) Insulation resistance 20 M min. (at 500 DC)
Dielectric strength 1,000 VAC, 50/60 Hz for 1 min
Vibration resistance (destruction)10 to 150 Hz with 0.7-mm double amplitude for 80 min each in X, Y, and Z directions Shock resistance (destruction)300 m/s2, 3 times each in 6 directions (up, down, left, right, forward, backward) Connection methodPrewired (standard cable length: 2 m)
Weight (packed state) Approx. 350 g
MaterialsCase: PBT (polybutylene terephthalate), cover: Polycarbonate
AccessoriesInstruction manual
*1The response speed of the linear output is calculated as the measurement period x (average count setting + 1) (with fixed sensitivity).
The response speed of the judgement outputs is calculated as the measurement period x (average count setting + 1) (with fixed sensitivity).
*2The output can be switched between a current output and voltage output using a switch on the bottom of the amplifier unit.
*3Setting is possible via the monitor focus function.
*4A calculating unit (ZX-CAL or ZX-CAL2) is required.
390

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

Latest Customer Reviews

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.