CS1W-PTS51 168520 OMRON Control System, Inputs Thermocouple Module 4 Isolation View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

CS1W-PTS51 168520 OMRON Control System, Inputs Thermocouple Module 4 Isolation

CS1W-PTS51

168520

OMRON

Available

Ship on today

Control System, Inputs Thermocouple Module 4 Isolation

More details


Programmable Logic Controllers Plcs

CS1

* Brand new product in its original packaging covered by the warranties and certifications provided by OMRON

Quantity Price
1+$961.68
2+$957.47
*This price is per unit and is the net value (not including taxes if applicable).

Related products

More info



CS-Series analogand process I/O unitsRack PLC
From basic analog I/O to process control
CS1 offers a wide choice of analog input units, fit for any application, from low-speed, multi-channel temperaturemeasurementto high-speed, high-accuracy data acquisi- tion. Analog outputs can be used for accurate control or external indication.
Advanced units with built-in scaling, filtering and alarm functions reduce the need for complex PLC programming.High-accuracy process I/O units supportan extensive
range of sensors, for fast and accurate data acquisition. All processandtemperature
I/O units provide isolation betweenall individual channels.
Ordering information
PointsType Ranges Resolution Accuracy*1 Conversion time
Remarks Connection type
Order code
4Analog input 0 to 5 V,
1/8,000V: 0.2% of PV
250 μs/pointOffset/gain adjustment, peak hold,
M3 CS1W-AD041-V1
8Analog input
0 to 10 V,
–10 to 10 V,
I: 0.4%of PV
moving average, alarms
M3 CS1W-AD081-V1
16Analog input
1 to 5 V,
4 to 20 mA
0.2% of PV2 × MIL (34p.) CS1W-AD161
4Analog output 0 to 5 V,
0 to 10 V,
–10 to 10 V,
1 to 5 V,
4 to 20 mA
1/4,000V: 0.3% of PV I: 0.5%of PV
1 ms/point Offset/gain adjustmentM3 CS1W-DA041
8Voltage output0 to 5 V,
0 to 10 V,
–10 to 10 V,
1 to 5 V
0.3% of PVOffset/gain adjustment, output hold M3 CS1W-DA08V
8Current output4 to 20 mA 0.5% of PV M3 CS1W-DA08C
4 + 4Analog in + output0 to 5 V,
0 to 10 V,
–10 to 10 V,
1 to 5 V
(4 to 20 mA input)
1/8,000V in: 0.2% of PV I in: 0.4% of PV out: 0.3% of PV
1 ms/point Offset/gain adjustment, scaling, peak hold, moving average, alarms, output hold
M3 CS1W-MAD44
4Process input 4 to 20 mA,
0 to 20 mA,
0 to 10 V,
–10 to 10 V,
0 to 5 V,
–5 to 5 V,
1 to 5 V,
1 to 1.25 V,
–1.25 to 1.25 V
1/64,0000.05% of PV 5 ms/point Configurable alarms, maintenance functions, user-defined scaling, zero/ span adjustment, square root, totalis- er.
M3 CS1W-PDC11
8Process input–10 to 10 V,
0 to 5 V,
1 to 5 V,
4 to 20 mA
1/16,0000.3% of PV 62.5 ms/pointConfigurable alarms, zero/span adjust- M3 CS1W-PDC55 ment, square root
4Thermocouple inputB, E, J, K, L, N, R, S, T, U, WRe5-26, PLII,
–100 to 100 mV
1/64,0000.05% of PV 5 ms/point Configurable alarms (absolute + rate-of-change), peak hold, maintenance functions
M3 CS1W-PTS11
4Resistance thermometer in- put
Pt50, Pt100 JPt100, Ni508.4
1/64,0000.05% of PV 5 ms/point Configurable alarms (absolute + rate-of-change), peak hold, maintenance functions
M3 CS1W-PTS12
4Thermocouple input B, J, K, L, R, S, T 0.1°C0.3%of PV 62.5ms/point4 configurable alarm outputs M3 CS1W-PTS51
4Resistance thermometer in- put
Pt100, JPt100 0.1°C0.3% of PV62.5 ms/point4 configurable alarm outputs M3 CS1W-PTS52
8Thermocouple input B, J, K, L, R,S, T0.1°C0.3%of PV 31.2ms/pointConfigurable alarms per channelM3 CS1W-PTS55
8Resistance thermometer in- put
Pt100, JPt100 0.1°C0.3% of PV31.2 ms/pointConfigurable alarms per channelM3 CS1W-PTS56
42-Wire transmitter input1 to 5 V,
4 to 20 mA
8Power transducer input –1 to 1 mA,
0 to 1 mA
8Power transducer input –100 to 100 mV,
0 to 100 mV
1/4,096 0.2% of FS25 ms/point Built-in power supply for transmitter, configurable alarms, square root,
rate-of-change, etc.
1/4,096 0.2% of FS25 ms/point Inrush current limiter, configurable alarms, averaging, etc.
1/4,096 0.2% of FS25 ms/point Inrush current limiter, configurable alarms, averaging, etc.
M3 CS1W-PTW01
M3 CS1W-PTR01
M3 CS1W-PTR02
4Pulse rate input 20000 pps, voltage,
up to
–25 ms/point Averaging, totaliser M3 CS1W-PPS01
open collector, contact1/32,000
40
CS-Series analogand process I/O unitsRack PLC
PointsType Ranges Resolution Accuracy*1 Conversion time
Remarks Connection type
Order code
4Isolated control output1 to 5 V,
4 to 20 mA
1/4,000I: 0.1%of FS V: 0.2%of FS
25 ms/point Output readback, high/low/rate limit-M3 CS1W-PMV01 ing, disconnection alarm, zero/span
adjustment
4Isolated control output–10 to 10 V,
0 to 10 V,
–5 to 5 V,
0 to 5 V,
–1 to 1 V,
0 to 1 V
1/4,0000.1% of FS10 ms/point High/low/rate limiting, output hold, zero/span adjustment
M3 CS1W-PMV02
*1Accuracy for Voltage and Current Inputs/Outputs as percentage of full scale and typical value at 25°C ambient temperature (Consult the operation manual for details) Accuracy for Temperature Inputs/Outputs as percentage of process value and typical value at 25°C ambient temperature (Consult the operation manual for details)
Note:All analog I/O units are designated as special I/O units
41

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

Latest Customer Reviews

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.