ANUNCIAR
V20-C 0-300PV 5099611 OBO BETTERMANN SurgeController V20 plug-in arrester f. PV systems, 300V DC, View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

V20-C 0-300PV 5099611 OBO BETTERMANN SurgeController V20 plug-in arrester f. PV systems, 300V DC,

V20-C 0-300PV

5099611

OBO BETTERMANN

SurgeController V20 plug-in arrester f. PV systems, 300V DC,

PV SurgeController V20, plug-in arrester, type 2. SurgeController upper part - type 2, surge arrester for photovoltaic systems• For surge protection equipotential bonding to VDE 0100-443 (IEC 60364-4-44)• Arresting capacity to 40 kA (8/20) per pole• Low DC voltage protection level: < 1.3 kV per pole (Y circuit: 2.6 kV and Voc max = 600 V DC)• Plug-in arrester with thermodynamic cut-off unit and visual function display• Encapsulated, non-extinguishing zinc oxide varistor arrester for use in distributor housings• High current carrying capacity with long lifespan Application example: PV systems with or without separated insulated lightning protection system

More details


Earthing, lightning and surge protection > Surge protection device for power supply systems

TBS Transient and lightning protection systems - OBO BETTERMANN > Surge protection, photovoltaics - OBO BETTERMANN

Brand new product in its original packaging covered by the warranties and certifications provided by OBO BETTERMANN

Total: $55.50
Unit price: $55.50
This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Related products

Often bought together

Best sellers

More info



CO2 Footprint (GWP) Cradle-to-Gate0,1685 kg CO2e / 1 Piece
Conductor cross-section, rigid (single-wire/multiwire), max.35 mm²
Conductor cross-section, rigid (single-wire/multiwire), min.2,5 mm²
DC network formyes
Dimension300V DC
Installation typeOn basic element
Integrated back-up fuseno
IT network formno
Lightning protection zone LPZ1→2
Max. mains-side overcurrent protection125
Maximum back-up fuse125 A
Maximum continuous voltage AC300 V
Maximum continuous voltage DC300 V
Maximum discharge current (8/20 μs)40 kA
Network formTN
Nominal discharge current (8/20 µs)20 kA
Nominal voltage AC (50/60 Hz)400 V
Operating temperature, max.80 °C
Operating temperature, min.-40 °C
Other network formno
Permitted temperature range, max.80 °C
Permitted temperature range, min.-40 °C
Pole version1
Protection ratingIP20
Remote signallingno
Response time<25 ns
Signalling on deviceVisual
SPD to EN 61643-11Type 2
SPD to IEC 61643-1Class II
Test class, type 2yes
TN network formyes
TN-C network formyes
TN-C-S network formyes
TN-S network formyes
TT network formyes
Version for1-pole, PV upper part with Y base to 600 V DC

Datasheet - PDF

Reviews (3)

  • simona
    Customer rating:
  • nocino
    Customer rating:
  • fulvio usala
    Customer rating:
  • Page:1
    Add Review
    hide form
    Rating:
    Name:
    Email:
    Subject:
    Text:
      Captcha
      Add review

    All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.