6ES7151-8FB01-0AB0 SIEMENS SIMATIC DP, IM151-8F PN/DP CPU f. ET200S, 256 KB work memory, int. PROFINET inter..

6ES7151-8FB01-0AB0

SIEMENS

SIMATIC DP, IM151-8F PN/DP CPU f. ET200S, 256 KB work memory, int. PROFINET interface (with three RJ45 ports) as IO controller/I-device without battery, MMC required

More details


PLC's > Fieldbus, decentr. periphery - basic appliance

AUTOMATION SYSTEMS > SIMATIC - Discontinued S7 product

Brand new product in its original packaging covered by the warranties and certifications provided by SIEMENS

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



ETIM: EC001603 - Fieldbus, decentr. periphery - basic appliance

Value Unit
With integrated power supply (EF003338) false
Input voltage at AC 50 Hz (EF007118) ['-', '-']V
Input voltage at AC 60 Hz (EF007119) ['-', '-']V
Input voltage at DC (EF007120) ['20.4', '28.8']V
Type of voltage (input voltage) (EF003033) DC
Max. input current AC 50 Hz (EF007360) -A
Max. input current AC 60 Hz (EF007361) -A
Max. input current DC (EF007362) 0.352A
Output voltage at AC 50 Hz (EF006999) ['-', '-']V
Output voltage at AC 60 Hz (EF007000) ['-', '-']V
Output voltage at DC (EF007001) ['-', '-']V
Type of output voltage (EF008222) -
Max. output current AC 50 Hz (EF007351) -A
Max. output current AC 60 Hz (EF007352) -A
Max. output current DC (EF007353) -A
Number of HW-interfaces industrial Ethernet (EF003020) 1
Number of interfaces PROFINET (EF006932) 3
Number of HW-interfaces RS-232 (EF003021) 0
Number of HW-interfaces RS-422 (EF003022) 0
Number of HW-interfaces RS-485 (EF003023) 0
Number of HW-interfaces serial TTY (EF003024) 0
Number of HW-interfaces USB (EF003025) 0
Number of HW-interfaces parallel (EF003026) 0
Number of HW-interfaces Wireless (EF006933) 0
Number of HW-interfaces other (EF003027) 0
With optical interface (EF003028) false
Supporting protocol for TCP/IP (EF003050) true
Supporting protocol for PROFIBUS (EF003052) false
Supporting protocol for CAN (EF003053) false
Supporting protocol for INTERBUS (EF003054) false
Supporting protocol for ASI (EF003051) false
Supporting protocol for KNX (EF003055) false
Supporting protocol for Modbus (EF003057) true
Supporting protocol for Data-Highway (EF003058) false
Supporting protocol for DeviceNet (EF003059) false
Supporting protocol for SUCONET (EF003060) false
Supporting protocol for LON (EF003017) false
Supporting protocol for SERCOS (EF006657) false
Supporting protocol for PROFINET IO (EF007525) true
Supporting protocol for PROFINET CBA (EF007524) true
Supporting protocol for Foundation Fieldbus (EF007522) false
Supporting protocol for EtherNet/IP (EF007521) false
Supporting protocol for AS-Interface Safety at Work (EF007519) false
Supporting protocol for DeviceNet Safety (EF007520) false
Supporting protocol for INTERBUS-Safety (EF006662) false
Supporting protocol for PROFIsafe (EF007526) true
Supporting protocol for SafetyBUS p (EF007527) false
Supporting protocol for other bus systems (EF003062) true
Radio standard Bluetooth (EF007178) false
Radio standard WLAN 802.11 (EF007179) false
Radio standard GPRS (EF008523) false
Radio standard GSM (EF008524) false
Radio standard UMTS (EF008525) false
IO link master (EF007298) false
System accessory (EF004118) true
Degree of protection (IP) (EF005474) IP20
Number of slots (EF003077) 63
With pluggable modules, digital I/O (EF003078) true
With pluggable modules, analogue I/O (EF003079) true
With pluggable modules, communication modules (EF003080) true
With pluggable modules, function and technology modules (EF003081) true
With pluggable modules, central modules (EF003082) true
With pluggable modules, others (EF003083) true
Type of electric connection (EF003961) Screw-/spring clamp connection
With potential separation (EF003272) true
Fieldbus connection over separate bus coupler possible (EF004002) true
With bus coupler for modular station connection (EF003990) true
Rail mounting possible (EF003972) true
Wall mounting/direct mounting (EF007020) true
Front build in possible (EF007016) -
Rack-assembly possible (EF007018) -
Suitable for safety functions (EF001597) true
Category according to EN 954-1 (EF006782) 4
SIL according to IEC 61508 (EF009889) 3
Performance level according to EN ISO 13849-1 (EF007399) Level e
Appendant operation agent (Ex ia) (EF004141) false
Appendant operation agent (Ex ib) (EF004142) false
Explosion safety category for gas (EF003997) ATEX gas-ex-protection, Cat. 3G
Explosion safety category for dust (EF003998) None
Width (EF000008) 120.0mm
Height (EF000040) 119.5mm
Depth (EF000049) 75.0mm


SIMATIC DP, IM151-8F PN/DP CPU f. ET200S, 256 KB work memory, int. PROFINET interface (with three RJ45 ports) as IO controller/I-device without battery, MMC required
General information
HW functional status01
Firmware versionV3.2
Product function
● Isochronous modeNo
Engineering with
● Programming packageSTEP 7 V5.5 or higher, Distributed Safety V5.4 SP4
Supply voltage
Rated value (DC)24 V
permissible range, lower limit (DC)20.4 V
permissible range, upper limit (DC)28.8 V
Reverse polarity protectionYes; against destruction
external protection for power supply lines (recommendation)2 A min.
Mains buffering
● Mains/voltage failure stored energy time5 ms
Input current
Inrush current, max.1.8 A; Typical
I²t0.13 A²·s
from supply voltage 1L+, max.352 mA; 426 mA with DP master module
Output current
for backplane bus (5 V DC), max.700 mA
Power loss
Power loss, typ.5.5 W
Memory
Work memory
● integrated256 kbyte; For program and data
● expandableNo
● Size of retentive memory for retentive data blocks64 kbyte
Load memory
● Plug-in (MMC)Yes
● Plug-in (MMC), max.8 Mbyte
● Data management on MMC (after last programming), min.10 y
Backup
● presentYes; Ensured by SIMATIC Micro Memory Card (maintenance-free)
CPU processing times
for bit operations, typ.0.06 µs
for word operations, typ.0.12 µs
for fixed point arithmetic, typ.0.16 µs
for floating point arithmetic, typ.0.59 µs
CPU-blocks
Number of blocks (total)1 024; (DBs, FCs, FBs); the maximum number of loadable blocks can be reduced by the MMC used.
DB
● Number, max.1 024; Number range: 1 to 16000
● Size, max.64 kbyte
FB
● Number, max.1 024; Number range: 0 to 7999
● Size, max.64 kbyte
FC
● Number, max.1 024; Number range: 0 to 7999
● Size, max.64 kbyte
OB
● DescriptionSee S7-300 operation list
● Size, max.64 kbyte
● Number of free cycle OBs1; OB 1
● Number of time alarm OBs1; OB 10
● Number of delay alarm OBs2; OB 20, 21
● Number of cyclic interrupt OBs4; OB 32, 33, 34, 35
● Number of process alarm OBs1; OB 40
● Number of DPV1 alarm OBs3; OB 55, 56, 57
● Number of isochronous mode OBs1; OB 61; only for PROFINET
● Number of startup OBs1; OB 100
● Number of asynchronous error OBs6; OB 80, 82, 83, 85, 86, 87 (OB83 only for centralized I/O and PROFINET IO)
● Number of synchronous error OBs2; OB 121, 122
Nesting depth
● per priority class16
● additional within an error OB4
Counters, timers and their retentivity
S7 counter
● Number256
Retentivity
— adjustableYes
— lower limit0
— upper limit255
— presetZ 0 to Z 7
Counting range
— adjustableYes
— lower limit0
— upper limit999
IEC counter
● presentYes
● TypeSFB
● NumberUnlimited (limited only by RAM capacity)
S7 times
● Number256
Retentivity
— adjustableYes
— lower limit0
— upper limit255
— presetNo retentivity
Time range
— lower limit10 ms
— upper limit9 990 s
IEC timer
● presentYes
● TypeSFB
● NumberUnlimited (limited only by RAM capacity)
Data areas and their retentivity
Flag
● Number, max.256 byte
● Retentivity availableYes
● Retentivity presetMB 0 to MB 15
● Number of clock memories8; 1 memory byte
Data blocks
● Retentivity adjustableYes; via non-retain property on DB
● Retentivity presetYes
Local data
● per priority class, max.32 768 byte; Max. 2048 bytes per block
Address area
I/O address area
● Inputs2 048 byte
● Outputs2 048 byte
of which distributed
— Inputs2 048 byte
— Outputs2 048 byte
Process image
● Inputs, adjustable2 048 byte
● Outputs, adjustable2 048 byte
● Inputs, default128 byte
● Outputs, default128 byte
Subprocess images
● Number of subprocess images, max.1; With PROFINET IO, the length of the user data is limited to 1600 bytes
Digital channels
● Inputs16 336
— of which central496
● Outputs16 336
— of which central496
Analog channels
● Inputs1 021
— of which central124
● Outputs1 021
— of which central124
Hardware configuration
Number of modules per system, max.63; Centralized
Mounting rail
● Number of mounting rails that can be used1
● Length of mounting rail, max.Station width: ≤ 1 m or < 2 m
Time of day
Clock
● Hardware clock (real-time)Yes
● retentive and synchronizableYes
● Backup time6 wk; At 40 °C ambient temperature, typically
● Deviation per day, max.10 s; Typ.: 2 s
● Behavior of the clock following POWER-ONClock continues running after POWER OFF
● Behavior of the clock following expiry of backup periodClock continues to run with the time at which the power failure occurred
Operating hours counter
● Number1
● Number/Number range0
● Range of values0 to 2^31 hours (when using SFC 101)
● Granularity1 h
● retentiveYes; Must be restarted at each restart
Clock synchronization
● supportedYes
● to MPI, masterNo
● to MPI, slaveNo
● to DP, masterYes; With DP master module
● to DP, slaveYes; With DP master module
● in AS, masterNo
● in AS, slaveNo
● on Ethernet via NTPYes; As client
1. Interface
Interface typePROFINET
PhysicsEthernet
IsolatedYes
automatic detection of transmission rateYes
AutonegotiationYes
AutocrossingYes
Change of IP address at runtime, supportedYes
Interface types
● Number of ports3; RJ45
● integrated switchYes
Protocols
● MPINo
● PROFINET IO ControllerYes; Also simultaneously with IO-Device functionality
● PROFINET IO DeviceYes; Also simultaneously with IO Controller functionality
● PROFINET CBAYes
● PROFIBUS DP masterNo
● PROFIBUS DP slaveNo
● Open IE communicationYes; Via TCP/IP, ISO on TCP, and UDP
● Web serverYes
● Point-to-point connectionNo
PROFINET IO Controller
● Transmission rate, max.100 Mbit/s; full duplex
Services
— PG/OP communicationYes
— RoutingYes; With DP master module
— S7 communicationYes; with loadable FBs
— Isochronous modeYes; OB 61; only for PROFINET IO
— IRTYes
— MRPYes
— Shared deviceYes
— Prioritized startupYes
— Number of IO devices with prioritized startup, max.32
— Number of connectable IO Devices, max.128
— Of which IO devices with IRT, max.64
— of which in line, max.64
— Number of IO Devices with IRT and the option "high flexibility"128
— of which in line, max.61
— Number of connectable IO Devices for RT, max.128
— of which in line, max.128
— Activation/deactivation of IO DevicesYes
— Number of IO Devices that can be simultaneously activated/deactivated, max.8
— IO Devices changing during operation (partner ports), supportedYes
— Number of IO Devices per tool, max.8
— Device replacement without swap mediumYes
— Send cycles250 μs, 500 μs,1 ms; 2 ms, 4 ms (not in the case of IRT with "high flexibility" option)
— Updating timeMinimum value depends on communication share set for PROFINET I/O, on the number of I/O devices, and on the number of configured user data items.
— Updating times250 µs to 512 ms (depends on operating mode; for more details, refer to Operating Instructions, "Interface Module IM151-8 PN/DP CPU")
Address area
— Inputs, max.2 kbyte
— Outputs, max.2 kbyte
— User data consistency, max.1 024 byte; with PROFINET I/O
PROFINET IO Device
Services
— PG/OP communicationYes
— RoutingYes
— S7 communicationYes; with loadable FBs
— Isochronous modeNo
— IRTYes
— MRPYes
— PROFIenergyYes; With SFB 73 / 74 prepared for loadable PROFIenergy standard FB for I-Device
— Shared deviceYes
— Number of IO Controllers with shared device, max.2
Transfer memory
— Inputs, max.1 440 byte; Per IO Controller with shared device
— Outputs, max.1 440 byte; Per IO Controller with shared device
Submodules
— Number, max.64
— User data per submodule, max.1 024 byte
PROFINET CBA
● acyclic transmissionYes
● cyclic transmissionYes
Open IE communication
● Number of connections, max.8
● Local port numbers used at the system end0, 20, 21, 23, 25, 80, 102, 135, 161, 443, 8080, 34962, 34963, 34964, 65532, 65533, 65534, 65535
2. Interface
Interface typeExternal interface via master module 6ES7138-4HA00-0AB0
PhysicsRS 485
IsolatedYes
Power supply to interface (15 to 30 V DC), max.No
Protocols
● MPINo
● PROFINET IO ControllerNo
● PROFINET IO DeviceNo
● PROFINET CBANo
● PROFIBUS DP masterYes
● PROFIBUS DP slaveNo
● Open IE communicationNo
● Web serverNo
PROFIBUS DP master
● Transmission rate, max.12 Mbit/s
● Number of DP slaves, max.32; Per station
Services
— PG/OP communicationYes
— RoutingYes
— Global data communicationNo
— S7 basic communicationYes; I blocks only
— S7 communicationYes
— S7 communication, as clientNo
— S7 communication, as serverYes
— EquidistanceYes
— Isochronous modeNo
— SYNC/FREEZEYes
— Activation/deactivation of DP slavesYes
— Number of DP slaves that can be simultaneously activated/deactivated, max.8
— Direct data exchange (slave-to-slave communication)Yes
— DPV1Yes
Address area
— Inputs, max.2 048 byte
— Outputs, max.2 048 byte
User data per DP slave
— Inputs, max.244 byte
— Outputs, max.244 byte
Protocols
Redundancy mode
Media redundancy
— Switchover time on line break, typ.200 ms; PROFINET MRP
— Number of stations in the ring, max.50
Open IE communication
● TCP/IPYes; via integrated PROFINET interface and loadable FBs
— Number of connections, max.8
— Data length for connection type 01H, max.1 460 byte
— Data length for connection type 11H, max.32 768 byte
— several passive connections per port, supportedYes
● ISO-on-TCP (RFC1006)Yes; via integrated PROFINET interface and loadable FBs
— Number of connections, max.8
— Data length, max.32 768 byte
● UDPYes; via integrated PROFINET interface and loadable FBs
— Number of connections, max.8
— Data length, max.1 472 byte
Web server
● supportedYes
● User-defined websitesYes
● Number of HTTP clients5
Communication functions
PG/OP communicationYes
Data record routingYes; With DP master module
Global data communication
● supportedNo
S7 basic communication
● supportedYes; I blocks
● User data per job, max.76 byte
● User data per job (of which consistent), max.76 byte
S7 communication
● supportedYes
● as serverYes
● as clientYes; via integrated PROFINET interface and loadable FBs
● User data per job, max.See online help of STEP 7 (shared parameters of the SFBs/FBs and of the SFCs/FCs of S7 Communication)
PROFINET CBA (at set setpoint communication load)
● Setpoint for the CPU communication load50 %
● Number of remote interconnection partners32
● Number of functions, master/slave30
● Total of all master/slave connections1 000
● Data length of all incoming connections master/slave, max.4 000 byte
● Data length of all outgoing connections master/slave, max.4 000 byte
● Number of device-internal and PROFIBUS interconnections500
● Data length of device-internal und PROFIBUS interconnections, max.4 000 byte
● Data length per connection, max.1 400 byte
Remote interconnections with acyclic transmission
— Sampling interval, min.500 ms
— Number of incoming interconnections100
— Number of outgoing interconnections100
— Data length of all incoming interconnections, max.2 000 byte
— Data length of all outgoing interconnections, max.2 000 byte
— Data length per connection, max.1 400 byte
Remote interconnections with cyclic transmission
— Transmission frequency: Transmission interval, min.1 ms
— Number of incoming interconnections200
— Number of outgoing interconnections200
— Data length of all incoming interconnections, max.2 000 byte
— Data length of all outgoing interconnections, max.2 000 byte
— Data length per connection, max.450 byte
HMI variables via PROFINET (acyclic)
— Number of stations that can log on for HMI variables (PN OPC/iMap)3; 2x PN OPC/1x iMap
— HMI variable updating500 ms
— Number of HMI variables200
— Data length of all HMI variables, max.2 000 byte
PROFIBUS proxy functionality
— supportedYes
— Number of linked PROFIBUS devices16
— Data length per connection, max.240 byte; Slave-dependent
iPAR server
● supportedYes
Number of connections
● overall12
● usable for PG communication11
— reserved for PG communication1
— adjustable for PG communication, min.1
— adjustable for PG communication, max.11
● usable for OP communication11
— reserved for OP communication1
— adjustable for OP communication, min.1
— adjustable for OP communication, max.11
● usable for S7 basic communication10
— reserved for S7 basic communication0
— adjustable for S7 basic communication, min.0
— adjustable for S7 basic communication, max.10
● usable for S7 communication10; with loadable FBs
— adjustable for S7 communication, max.10
● total number of instances, max.32
● usable for routing4; max.
S7 message functions
Number of login stations for message functions, max.12; Depending on the configured connections for PG/OP and S7 basic communication
Process diagnostic messagesYes; ALARM_S, ALARM_SC, ALARM_SQ, ALARM_D, ALARM_DQ
simultaneously active Alarm-S blocks, max.300
Test commissioning functions
Status blockYes; Up to 2 simultaneously
Single stepYes
Number of breakpoints4
Status/control
● Status/control variableYes
● VariablesInputs, outputs, memory bits, DB, times, counters
● Number of variables, max.30
— of which status variables, max.30
— of which control variables, max.14
Forcing
● ForcingYes
● Forcing, variablesI/O
● Number of variables, max.10
Diagnostic buffer
● presentYes
● Number of entries, max.500
— adjustableNo
— of which powerfail-proof100; Only the last 100 entries are retained
Interrupts/diagnostics/status information
AlarmsYes
Diagnostics functionYes
Diagnostics indication LED
● for maintenanceYes; MT
● Bus fault BF (red)Yes; BF-PN
● Group error SF (red)Yes
● Monitoring 24 V voltage supply ON (green)Yes
● Bus activity PROFINET (green)Yes; P1-/P2-/P3-Link
Potential separation
between PROFIBUS DP and all other circuit componentsYes
Isolation
Isolation tested with500 V DC
Degree and class of protection
IP degree of protectionIP20
Configuration
Configuration software
● STEP 7Yes; V5.5 or higher
Programming
● Command setsee instruction list
● Nesting levels8
● System functions (SFC)see instruction list
● System function blocks (SFB)see instruction list
Programming language
— LADYes
— FBDYes
— STLYes
— SCLYes; Optional
— CFCYes; Optional
— GRAPHYes; Optional
— HiGraph®Yes; Optional
Know-how protection
● User program protection/password protectionYes
● Block encryptionYes; With S7 block Privacy
Cycle time monitoring
● lower limit1 ms
● upper limit6 000 ms
● adjustableYes
● preset150 ms
Dimensions
Width120 mm; DP master module: 35 mm
Height119.5 mm
Depth75 mm
Weights
Weight, approx.320 g; DP master module: Approx. 100 g
last modified:08/28/2020


Product
Article Number (Market Facing Number)6ES7151-8FB01-0AB0
Product DescriptionSIMATIC DP, IM151-8F PN/DP CPU f. ET200S, 256 KB work memory, int. PROFINET interface (with three RJ45 ports) as IO controller/I-device without battery, MMC required
Product familyIM 151-8 F PN/DP CPU
Product Lifecycle (PLM)PM300:Active Product
Price data
Price Group241
Surcharge for Raw MaterialsNone
Metal FactorNone
Delivery information
Export Control RegulationsAL : N / ECCN : EAR99H
Standard lead time ex-works10 Day/Days
Net Weight (kg)0,396 Kg
Product Dimensions (W x L x H)Not available
Packaging Dimension13,20 x 15,30 x 9,10
Package size unit of measureCM
Quantity Unit1 Piece
Packaging Quantity1
Additional Product Information
EAN4025515078753
UPC040892692839
Commodity Code85389091
LKZ_FDB/ CatalogIDST76
Product Group4A9E
Group CodeR111
Country of originGermany
Compliance with the substance restrictions according to RoHS directiveSince: 21.05.2010
Product classA: Standard product which is a stock item could be returned within the returns guidelines/period.
WEEE (2012/19/EU) Take-Back ObligationYes
REACH Art. 33 Duty to inform according to the current list of candidates

Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):

4,4'-isopropylidenediphenol (Bisphenol A, BPA)

Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.

Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):

Lead

Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.

Classifications
VersionClassification
eClass627-24-26-07
eClass7.127-24-26-07
eClass827-24-26-07
eClass927-24-26-07
eClass9.127-24-26-07
ETIM4EC001603
ETIM5EC001603
ETIM6EC001603
ETIM7EC001603
IDEA43565
UNSPSC1443-20-15-03
UNSPSC1532-15-17-05

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.