51ADX0245B ADX0245B LOVATO SOFT STARTER, ADX TYPE, FOR SEVERE DUTY (STARTING CURRENT 5•IE). WITH INTEGRATED .. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

51ADX0245B ADX0245B LOVATO SOFT STARTER, ADX TYPE, FOR SEVERE DUTY (STARTING CURRENT 5•IE). WITH INTEGRATED ..

51ADX0245B

ADX0245B

LOVATO ELECTRIC

SOFT STARTER, ADX TYPE, FOR SEVERE DUTY (STARTING CURRENT 5•IE). WITH INTEGRATED BY-PASS CONTACTOR, 245A

ADX static starter. B with built-in by-pass (Severe Applications, starting current = 5Ie) 245A

Soft starter, ADX... type, for severe duty (starting current 5•Ie). With integrated bypass contactor, 245A

More details


Soft Starters / Starters Static - LOVATO ELECTRIC

* Brand new product in its original packaging covered by the warranties and certifications provided by LOVATO ELECTRIC

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



Order code51ADX0245B
Weight [g]39300
Qty. per package1
Multiple qty. of packs per order1
Package dimensions [mm]685X290X315
Volume [cm³]62574.75
Bar code [EAN13]8013975075401
HS Code85371098
Dimensions
ejumhweclq.jpg
Wiring diagram
spdxzrtqkc.jpg
Certifications:
EAC
Compliance:
IEC/EN 60947-1
IEC/EN 60947-4-2
Product designationSoft starter
Product type designationADX…B
Motor typeAsynchronous three phase
Electrical features
Supplies voltage
Type of systemThree phase
Rated supply voltageV208…500VAC
auxiliary supply voltage (Us)208…240VAC
Rated frequencyHz50/60
Rated starter current IeA245
Rated motor power
IEC ratings (T≤40°C)
230VACkW75
400VACkW132
500VACKW160
UL ratings (T≤40°C)
220-240VACHP75
380-415VACHP150
440-480VACHP200
Number of controlled phasesNr.3
Built-in bypassYes
Cooling SystemForced
Programming interface
DisplayBacklit LCD 2x16 character
Programming with NFC technologyNo
Optical portNo
Startup and stop settings
Startup methodTorque or voltage ramp with current limitation
Stop methodTorque ramp, voltage ramp, free-wheel stop
Braking methodDC dynamic with external relay
Protections
Auxiliary supply protectionVoltage too low
Power supply ProtectionNo power, phase loss, phase sequence, frequency out of limits, minimum and maximum voltage
Motor protectionOverload at starting (trip class 2, 10A, 10, 15, 20, 25, 30, 35 and 40), overload during running (trip class 2, 10A, 10, 15, 20, 25 and 30), locked rotor, current asymmetry, minimum torque (dry run), overtemperature , starting too long
Starter protectionOvercurrent, overtemperature, bypass failure, phase shorted, temperature sensor fault, maintenance request
Input and Output
Digital inputs
Number of digital inputNr.3 (2 digital inputs + 1 digital/analog input)
Digital input type24VDC (no need for external feeder)
Digital input functions1 input for start, 1 input programmable (stop, free-wheel stopping, external alarm, motor preheat, local control, alarms inhibit, manual resetting of motor thermal protection, keypad lock, second motor), 1 input programmable multifunction (OFF, free-wheel
Analog inputs
Number of analog inputNr.1 (digital/analog)
Analog input type0-10VDC (0-20mA with external resistor 500Ω)
Analog input functionsMotor protection via PTC probes, acceleration and/or deceleration ramp via analog input, analog input thresholds for motor starting and stopping, analog input thresholds for programmable relay enable and disable, PT100 input thresholds for motor starting a
Digital outputs
Number of digital outputNr.4
Digital output arrangement3 x 1 NO (SPST) + 1 C/O (SPDT)Ratings: 5A 250VAC AC1, 2A 250VAC AC15
Digital output functionsC/O output for global alarm, 3 x 1NO outputs programmable (OFF, motor powered, up to speed, braking, current limit, service required, cascade starting, programmable input thresholds, alarm Axx)
Analog outputs
Number of analog outputNr.1
Analog output type0...20mA, 4...20mA (0...10V with external resistor 500Ω)
Analog output functionsCurrent, torque, motor thermal status, power factor and active power
Ambient conditions
Temperature
Operating temperature
min°C-10
max°C+55°C (with current derating >45°C of 1.5%/°C )
Storage temperature
min°C-30
max°C+70
Max altitudem1000 without derating (over 1000mt with current derating of 0.5%/100m)
Relative humidity%95% without condensation or dripping
Pollution degree3
Housing
MountingScrew-fixing
IP degree of protectionIP00
Dimensions (W x H x D)mm273 x 680 x 310
WeightKg39.3
ETIM classification
ETIM 8.0EC000640 - Soft starter

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.