FOUR-POLE CONTACTOR, DC COIL, 60VDC, REAR PCB SOLDER PIN
Minicontactor Tetrapolar 20A AC1 Coil 60V DC Printed Circuit
Industrial Contactors and Accessories - LOVATO ELECTRIC
* Brand new product in its original packaging covered by the warranties and certifications provided by LOVATO ELECTRIC
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
Order code | 11BGP09T4D060 |
Weight [g] | 242 |
Qty. per package | 1 |
Multiple qty. of packs per order | 10 |
Package dimensions [mm] | 060X045X070 |
Volume [cm³] | 189 |
Bar code [EAN13] | 8013975145388 |
HS Code | 85365080 |
Product designation | Power contactor | |||
Product type designation | BGP09 | |||
Contact characteristics | ||||
Number of poles | nr. | 4 | ||
Rated insulation voltage Ui IEC/EN | V | 690 | ||
Rated impulse withstand voltage Uimp | kV | 6 | ||
Operational frequency | ||||
min | Hz | 25 | ||
max | Hz | 400 | ||
IEC Conventional free air thermal current Ith | A | 20 | ||
Operational current Ie | ||||
AC-1 (≤40°C) | A | 20 | ||
AC-1 (≤55°C) | A | 0 | ||
AC-3 (≤440V ≤55°C) | A | 9 | ||
AC-4 (400V) | A | 4 | ||
Rated operational power AC-1 (T≤40°C) | ||||
230V | kW | 8 | ||
400V | kW | 14 | ||
500V | kW | 16 | ||
690V | kW | 22 | ||
Short-time allowable current for 10s (IEC/EN60947-1) | A | 96 | ||
Protection fuse | ||||
gG (IEC) | A | 20 | ||
aM (IEC) | A | 10 | ||
Making capacity (RMS value) | A | 92 | ||
Breaking capacity at voltage | ||||
440V | A | 72 | ||
500V | A | 72 | ||
690V | A | 72 | ||
Resistance per pole (average value) | mΩ | 10 | ||
Power dissipation per pole (average value) | ||||
Ith | W | 4 | ||
AC3 | W | 0.81 | ||
Tightening torque for terminals | ||||
min | Nm | 0.8 | ||
max | Nm | 1 | ||
min | Ibin | 0.6 | ||
max | Ibin | 0.7 | ||
Tightening torque for coil terminal | ||||
min | Nm | 0.8 | ||
max | Nm | 1 | ||
min | Ibft | 0.59 | ||
max | Ibft | 0.74 | ||
Max number of wires simultaneously connectable | nr. | 2 | ||
Conductor section | ||||
Flexible w/o lug conductor section | ||||
min | mm² | 0.8 | ||
max | mm² | 2.5 | ||
Flexible c/w lug conductor section | ||||
min | mm² | 1.5 | ||
max | mm² | 2.5 | ||
Flexible with insulated spade lug conductor section | ||||
min | mm² | 1.5 | ||
max | mm² | 2.5 | ||
Power terminal protection according to IEC/EN 60529 | IP00 | |||
Mechanical features | ||||
Operating position | ||||
normal | Vertical plan | |||
allowable | ±30° | |||
Fixing | Screw / DIN rail 35mm | |||
Weight | g | 242 | ||
Auxiliary contact characteristics | ||||
Type of contact | 1 NA | |||
Thermal current Ith | A | 10 | ||
IEC/EN 60947-5-1 designation | Q600 | |||
Operations | ||||
Mechanical life | cycles | 20000000 | ||
Electrical life | cycles | 500000 | ||
Safety related data | ||||
Performance level B10d according to EN/ISO 13489-1 | ||||
rated load | cycles | 500000 | ||
mechanical load | cycles | 20000000 | ||
Mirror contats according to IEC/EN 609474-4-1 | yes | |||
EMC compatibility | yes | |||
DC coil operating | ||||
DC rated control voltage | V | 60 | ||
DC operating voltage | ||||
pick-up | ||||
min | %Us | 75 | ||
max | %Us | 115 | ||
drop-out | ||||
min | %Us | 10 | ||
max | %Us | 25 | ||
Average coil consumption ≤20°C | ||||
in-rush | W | 3.2 | ||
holding | W | 3.2 | ||
Max cycles frequency | ||||
Mechanical operation | cycles/h | 3600 | ||
Operating times | ||||
Average time for Us control | ||||
in AC | ||||
Closing NO | ||||
min | ms | 12 | ||
max | ms | 21 | ||
Opening NO | ||||
min | ms | 9 | ||
max | ms | 18 | ||
Closing NC | ||||
min | ms | 17 | ||
max | ms | 26 | ||
Opening NC | ||||
min | ms | 7 | ||
max | ms | 17 | ||
in DC | ||||
Closing NO | ||||
min | ms | 18 | ||
max | ms | 25 | ||
Opening NO | ||||
min | ms | 2 | ||
max | ms | 3 | ||
Closing NC | ||||
min | ms | 3 | ||
max | ms | 5 | ||
Opening NC | ||||
min | ms | 11 | ||
max | ms | 17 | ||
UL technical data | ||||
Full-load current (FLA) for three-phase AC motor | ||||
at 480V | A | 7.6 | ||
at 600V | A | 6.1 | ||
Yielded mechanical performance | ||||
for single-phase AC motor | ||||
110/120V | HP | 0.5 | ||
230V | HP | 1.5 | ||
for three-phase AC motor | ||||
200/208V | HP | 2 | ||
220/230V | HP | 3 | ||
460/480V | HP | 5 | ||
575/600V | HP | 5 | ||
General USE | ||||
Contactor | ||||
AC current | A | 20 | ||
Ambient conditions | ||||
Temperature | ||||
Operating temperature | ||||
min | °C | -50 | ||
max | °C | +70 | ||
Storage temperature | ||||
min | °C | -60 | ||
max | °C | +80 | ||
Max altitude | m | 3000 | ||
Resistance & Protection | ||||
Pollution degree | 3 | |||
ETIM classification | ||||
ETIM 8.0 | EC000066 - Power contactor, AC switching |
Title: | Size: | Type: |
---|---|---|
11BGP09T4D060 BGP09T4D060 02-Contactors-02-January-2018_EN.pdf | 6 Mbytes |
No customer reviews for the moment.
Rating: | |
Name: | |
Email: | |
Subject: | |
Text: | |
Do you recommend this product to buy? | |
Add review |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.