Product successfully added to your shopping cart
XV-440-12TSB-1-50
139915
EATON-MOELLER
1
Touch panel, ir, 24 V DC, 12.1z, TFTcolor, ethernet, RS232, CAN, (PLC), stainless steel
HMI Touch Terminals
Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
Product range | XV400 12.1 | ||
Product range | XV400 | ||
Function | HMI-PLC (PLC retrofitted by user) | ||
Common features of the model series | Ethernet interface USB device RS232 CAN/easyNet UL508, cUL approvals PLC function can be fitted by user Communications scope can be fitted by user with licenses | ||
Display - Type | Color display, TFT | ||
Touch-technology | Infra-red touch | ||
Number of colours | Adjustable: 65536 or 256 colours | ||
Resolution | Pixel | SVGA 800 x 600 | |
Portrait format | yes | ||
Screen diagonal | Inch | 12.1 | |
Model | Metal enclosure with stainless steel front | ||
Operating system | Windows CE (license required) CompactFlash card required | ||
PLC-licence | Can be fitted by user with article no. 140390 LIC-PLC-MXP-MEDIUM | ||
License certificates for onboard interfaces | Can be expanded as required, see Accessories -> License product certificates | ||
built-in interfaces | 1 x Ethernet 100base-TX/10base-T 1 x RS232 1 x CAN 2 x USB host 1 x USB device | ||
Front type | Satin-finish brushed stainless steel Laminated safety glass, non-reflective | ||
Utilization | Flush mounting | ||
Slots | for Compact-FlashTM-Cards: 2 for communication modules: 2 | ||
Memory card automation | required, see Accessories -> Memory cards | ||
Pluggable communication cards (optional) | yes | ||
Heat dissipation | W | 32 | |
| Instructions Approved for II 2G Ex px II IP5x (ATEX 94/9/EC): Zone 1, Category 2G (Only for flush-mounting in a pressurized enclosure! Max. permissible excess pressure: 10 mbar continuous.) Zone 2, Category 3G (Only for flush-mounting in a pressurized enclosure! Max. permissible excess pressure: 10 mbar continuous.) | |||
| Display | |||
Display - Type | Color display, TFT | ||
Screen diagonal | Inch | 12.1 | |
Resolution | Pixel | SVGA 800 x 600 | |
Visible screen area | mm | 246 x 185 | |
Number of colours | Adjustable: 65536 or 256 colours | ||
Contrast ratio (Normally) | Normally 350:1 | ||
Brightness | cd/m2 | Normally 350 | |
Back-lighting | 2 x CCFL dimmable via software | ||
Service life of back-lighting | h | Normally 50000 | |
Infra-red touch protective screen | Laminated safety glass, non-reflective | ||
| Operation | |||
Technology | Infra-red touch 95 x 71 logic channels | ||
| System | |||
Processor | RISC CPU, 32 Bit, 400 MHz | ||
Internal memory | DRAM (OS, Program and data memory): 64 MByte Flash (can be used for data backup): approx. 1.5 MByte available NVRAM (retained data): approx. 32 KByte available | ||
External memory | CF-Slot: 2 x CompactFlash Card type I/II for operating system, programs and data | ||
Back-up of real-time clock | |||
Battery (service life) | Zero maintenance | ||
Backup (time at zero voltage) | Normally 10 years | ||
Operating system | Windows CE (license required) CompactFlash card required | ||
| Engineering | |||
Visualisation software | GALILEO EPAM XSOFT-CODESYS-2 XSOFT-CODESYS-3 | ||
PLC-Programming software | XSOFT-CODESYS-2 XSOFT-CODESYS-3 | ||
| Interfaces, communication | |||
built-in interfaces | 1 x Ethernet 100base-TX/10base-T 1 x RS232 1 x CAN 2 x USB host 1 x USB device | ||
PLC-licence | Can be fitted by user with article no. 140390 LIC-PLC-MXP-MEDIUM | ||
USB Host | USB 2.0 (1.5 - 12 Mbit/s), not galvanically isolated | ||
USB device | USB 1.1, not galvanically isolated | ||
RS-232 | RS-232, not galvanically isolated (SUB-D plug 9 pole, UNC) | ||
CAN | CAN, galvanically isolated (SUB-D plug 9 pole, UNC) | ||
Slots | for Compact-FlashTM-Cards: 2 for communication modules: 2 | ||
Ethernet | 100Base-TX/10Base-T | ||
| Power supply | |||
Nominal voltage | 24 V DC SELV (safety extra low voltage) | ||
permissible voltage | Effective: 20.4-28.8 V DC (rated operating voltage -15%/+20%) Absolute with ripple: 19.2-30.0 V DC 35 V DC for a duration of < 100 ms | ||
Voltage dips | ms | ≤ 10 ms from rated voltage (24 V DC) 5 ms from undervoltage (20.4 V DC) | |
Power consumption | Pmax. | W | 32 |
Power consumption | W | Normally 14 | |
Heat dissipation | W | 32 | |
Note on heat dissipation | Heat dissipation with power consumption for 24 V 18 W for basic device + two times 4 W for communication modules + two times 3 W for USB modules | ||
Siemens MPI, (optional) | yes | ||
Type of fuse | Yes (fuse not accessible) | ||
Potential isolation | no potential isolation (0 V-connection to housing potential) | ||
| General | |||
Housing material | Metal, anodized | ||
Front type | Satin-finish brushed stainless steel Laminated safety glass, non-reflective | ||
Weight | kg | 5.7 | |
Degree of protection (IEC/EN 60529, EN50178, VBG 4) | IP65 (at front), IP20 (at rear) | ||
Approvals | |||
Approvals | cUL (UL508) | ||
Explosion protection (according to ATEX 94/9/EC) | II 3D Ex II T70°C IP5x: Zone 22, Category 3D (in relation to CE) EN60079-0, EN61241-1, EN13463 | ||
Applied standards and directives | |||
EMC | (in relation to CE) EN 61000-6-2 EN 61000-6-3 EN 61000-6-4 EN 61131-2 | ||
Product standards | EN 50178 EN 61131-2 | ||
Security | EN 60950 UL 60950 | ||
Mechanical shock resistance | g | according to IEC 60068-2-27 | |
Vibration | To IEC 68-2-6 | ||
| Environmental conditions | |||
Temperature | |||
Operation | ϑ | °C | 0 - +50 |
Storage / Transport | ϑ | °C | -20 - +60 |
Operating ambient temperature min. | °C | 0 | |
Operating ambient temperature max. | °C | +50 | |
Relative humidity | |||
Relative humidity | 10 - 95%, non-condensing | ||
| Supply voltage UAux | |||
Rated operational voltage | UAux | V | 24 V DC (-15/+20%) |
Protection against polarity reversal | Yes | ||
Potential isolation | No | ||
Technical data for design verification | |||
Rated operational current for specified heat dissipation | In | A | 0 |
Heat dissipation per pole, current-dependent | Pvid | W | 0 |
Equipment heat dissipation, current-dependent | Pvid | W | 0 |
Static heat dissipation, non-current-dependent | Pvs | W | 32 |
Heat dissipation capacity | Pdiss | W | 0 |
Operating ambient temperature min. | °C | 0 | |
Operating ambient temperature max. | °C | 50 | |
IEC/EN 61439 design verification | |||
10.2 Strength of materials and parts | |||
10.2.2 Corrosion resistance | Meets the product standard's requirements. | ||
10.2.3.1 Verification of thermal stability of enclosures | Meets the product standard's requirements. | ||
10.2.3.2 Verification of resistance of insulating materials to normal heat | Meets the product standard's requirements. | ||
10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects | Meets the product standard's requirements. | ||
10.2.4 Resistance to ultra-violet (UV) radiation | Please enquire | ||
10.2.5 Lifting | Does not apply, since the entire switchgear needs to be evaluated. | ||
10.2.6 Mechanical impact | Does not apply, since the entire switchgear needs to be evaluated. | ||
10.2.7 Inscriptions | Meets the product standard's requirements. | ||
10.3 Degree of protection of ASSEMBLIES | Meets the product standard's requirements. | ||
10.4 Clearances and creepage distances | Meets the product standard's requirements. | ||
10.5 Protection against electric shock | Does not apply, since the entire switchgear needs to be evaluated. | ||
10.6 Incorporation of switching devices and components | Does not apply, since the entire switchgear needs to be evaluated. | ||
10.7 Internal electrical circuits and connections | Is the panel builder's responsibility. | ||
10.8 Connections for external conductors | Is the panel builder's responsibility. | ||
10.9 Insulation properties | |||
10.9.2 Power-frequency electric strength | Is the panel builder's responsibility. | ||
10.9.3 Impulse withstand voltage | Is the panel builder's responsibility. | ||
10.9.4 Testing of enclosures made of insulating material | Is the panel builder's responsibility. | ||
10.10 Temperature rise | The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. | ||
10.11 Short-circuit rating | Is the panel builder's responsibility. | ||
10.12 Electromagnetic compatibility | Is the panel builder's responsibility. | ||
10.13 Mechanical function | The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
| PLC's (EG000024) / Graphic panel (EC001412) | |||
| Electric engineering, automation, process control engineering / Control / Operate and Observe (HMI) / Graphic panel (HMI) ([email protected] [BAA722010]) | |||
Supply voltage AC 50 Hz | V | 0 - 0 | |
Supply voltage AC 60 Hz | V | 0 - 0 | |
Supply voltage DC | V | 20.4 - 28.8 | |
Voltage type of supply voltage | DC | ||
Number of HW-interfaces industrial Ethernet | 1 | ||
Number of HW-interfaces PROFINET | 0 | ||
Number of HW-interfaces RS-232 | 1 | ||
Number of HW-interfaces RS-422 | 0 | ||
Number of HW-interfaces RS-485 | 0 | ||
Number of HW-interfaces serial TTY | 0 | ||
Number of HW-interfaces USB | 3 | ||
Number of HW-interfaces parallel | 0 | ||
Number of HW-interfaces Wireless | 0 | ||
Number of HW-interfaces other | 0 | ||
With SW interfaces | Yes | ||
Supporting protocol for TCP/IP | Yes | ||
Supporting protocol for PROFIBUS | Yes | ||
Supporting protocol for CAN | Yes | ||
Supporting protocol for INTERBUS | No | ||
Supporting protocol for ASI | No | ||
Supporting protocol for KNX | Yes | ||
Supporting protocol for MODBUS | Yes | ||
Supporting protocol for Data-Highway | No | ||
Supporting protocol for DeviceNet | Yes | ||
Supporting protocol for SUCONET | Yes | ||
Supporting protocol for LON | No | ||
Supporting protocol for PROFINET IO | No | ||
Supporting protocol for PROFINET CBA | No | ||
Supporting protocol for SERCOS | No | ||
Supporting protocol for Foundation Fieldbus | No | ||
Supporting protocol for EtherNet/IP | Yes | ||
Supporting protocol for AS-Interface Safety at Work | No | ||
Supporting protocol for DeviceNet Safety | No | ||
Supporting protocol for INTERBUS-Safety | No | ||
Supporting protocol for PROFIsafe | No | ||
Supporting protocol for SafetyBUS p | No | ||
Supporting protocol for other bus systems | Yes | ||
Radio standard Bluetooth | No | ||
Radio standard WLAN 802.11 | No | ||
Radio standard GPRS | No | ||
Radio standard GSM | No | ||
Radio standard UMTS | No | ||
IO link master | No | ||
Type of display | TFT | ||
With colour display | Yes | ||
Number of colours of the display | 65536 | ||
Number of grey-scales/blue-scales of display | 0 | ||
Screen diagonal | inch | 12.1 | |
Number of pixels, horizontal | 800 | ||
Number of pixels, vertical | 600 | ||
Useful project memory/user memory | kByte | 64000 | |
With numeric keyboard | Yes | ||
With alpha numeric keyboard | Yes | ||
Number of function buttons, programmable | 0 | ||
Number of buttons with LED | 0 | ||
Number of system buttons | 1 | ||
With touch screen | Yes | ||
With message indication | Yes | ||
With message system (incl. buffer and confirmation) | Yes | ||
Process value representation (output) possible | Yes | ||
Process default value (input) possible | Yes | ||
With recipes | Yes | ||
Number of password levels | 200 | ||
Printer output available | Yes | ||
Number of online languages | 100 | ||
Additional software components, loadable | Yes | ||
Degree of protection (IP), front side | IP65 | ||
Operation temperature | °C | 0 - 50 | |
Rail mounting possible | No | ||
Wall mounting/direct mounting | No | ||
Suitable for safety functions | No | ||
Width of the front | mm | 361 | |
Height of the front | mm | 279 | |
Built-in depth | mm | 88 | |
| Product Standards | UL 60950-01; CSA-C22.2 No. 60950-1; IEC/EN 61131-2; CE marking | ||
| UL File No. | E208621 | ||
| UL Category Control No. | NWGQ2, NWGQ8 | ||
| CSA File No. | UL report applies to both US and Canada | ||
| CSA Class No. | – | ||
| North America Certification | UL recognized, certified by UL for use in Canada | ||
| Conditions of Acceptability | The investigated Pollution Degree is: 2 Proper bonding to the end-product main protective earthing termination is: Required The following end-product enclosures are required: Fire, Electrical The unit must be supplied via a SELV source. The provided Ethernet Connection is only allowed to connect to inhouse networks. | ||
| Specially designed for North America | No | ||
| Current Limiting Circuit-Breaker | No | ||
| Degree of Protection | IEC: IP65, UL/CSA Type: - |
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOGUE EATON EN .pdf | 38 Mbytes |
|
| XV-440-12TSB-1-50 139915 139915_EN.pdf | 178 Kbytes |
![]() |
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.