Product name
Eaton XH web panel
Part no.
XH-303-10-A10-A00-2B
Product Length/Depth
269 millimetre
Product height
58 millimetre
Product width
174 millimetre
Product weight
1.165 kilogram
Certifications
RoHS
CE
EN 61000-6-2
EMC
EN 61000-6-3
Catalog Notes
Heat dissipation with power consumption for 24 V, all ports and interfaces connected
Enclosure material
Insulated material
Features
USB Host
Ethernet interface
Fanless CPU and system cooling, natural convection-based passive cooling
Portrait format
Fitted with:
Color display
1 x USB host (built-in interface)
Degree of protection
IP20, rear (according to EN 60529-1)
Degree of protection (front side)
NEMA 4X
IP65
Fuse type
Built-in fuse (not accessible)
Lifespan
50,000 h (Service life of back-lighting)
Model
Plastic enclosure and glass panel in plastic frame
Mounting method
Flush mounting - Clearance: Width x Height x Depth ≥ 30 mm (1.18")
Flush mounting - Inclination from vertical: ±45° (if using natural convection)
Protection against polarity reversal
Yes
Product category
XH-300 HMI Webpanel
Ambient conditions, mechanical
Shock resistance
15 g, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 11 ms, 18 Impacts
Vibration resistance
According to IEC/EN 60068-2-6
Climatic environmental conditions
Air pressure
795 - 1080 hPa (operation)
Ambient operating temperature - min
0 °C
Ambient operating temperature - max
50 °C
Ambient storage temperature - min
-20 °C
Ambient storage temperature - max
60 °C
Environmental conditions
Condensation: prevent with appropriate measures
Operating temperature - min
0 °C
Operating temperature - max
0 °C
Relative humidity
10 - 95 % (non-condensing)
Electro magnetic compatibility
Voltage dips
5 ms from undervoltage (19.2 V DC)
≤ 10 ms from rated voltage (24 V DC)
Permissible voltage
18.0 - 31.2 V DC, absolute with ripple
35 V DC (for a duration of < 100 ms)
18 - 31.2 V DC, battery powered (rated operating voltage -25 %/+30 %)
19.2 - 30 V DC, effective (rated operating voltage -20 %/+25 %)
Power consumption
11.5 W typ.
Max. 15.4 W
2.5 W (USB Slave to USB Host)
12.5 W
Rated control supply voltage
24 V DC (UAUX, -20 %/+25 %)
Rated operational current (Ie)
0.64 A
Rated operational voltage
24 V DC (power-supply - safety extra low voltage)
Supply voltage at AC, 50 Hz - min
0 V
Supply voltage at AC, 50 Hz - max
0 V
Supply voltage at DC - min
19.2 V
Supply voltage at DC - max
30 V
Interfaces
USB 2.0 host (not galvanically isolated)
Ethernet (100Base-TX/10Base-T)
Display lighting
LED
Dimmable via software
Display type
TFT
Color display, TFT
Luminance intensity
800 cd/m²
Number of colors of the display
65536
Screen size (diagonal)
10.1 in
Touch technology
Capacitive multitouch
Multi-touch touch panel touch sensor
Memory
DDR4-RAM: 2 GByte
eMMC: 8 GByte
Memory capacity
2,000,000 kByte
Processor
ARM Cortex-A53, Quad-Core, 1.8 GHz
Equipment heat dissipation, current-dependent Pvid
11.5 W
Heat dissipation capacity Pdiss
0 W
Heat dissipation per pole, current-dependent Pvid
0 W
Static heat dissipation, non-current-dependent Pvs
11.5 W
10.2.2 Corrosion resistance
Please enquire
10.2.3.1 Verification of thermal stability of enclosures
Please enquire
10.2.3.2 Verification of resistance of insulating materials to normal heat
Please enquire
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Please enquire
10.2.4 Resistance to ultra-violet (UV) radiation
Please enquire
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Please enquire
10.3 Degree of protection of assemblies
Please enquire
10.4 Clearances and creepage distances
Please enquire
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.