Product successfully added to your shopping cart
SN3-050-EU8
100643
EATON-MOELLER
1
Switched-mode power supply unit, 24-28VDC, adjustable, 5A
Home > EATON - MOELLER
* Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
Product range | SN3 switched-mode power supply units | ||
Description | Primary pulsed power supply, power reserve from up to 50 % Up to 5 devices can be paralleled to increase power and for redundancy | ||
Phases | Single-phase | ||
Input voltage range | 85 - 264 V AC 100 - 350 V DC | ||
Instructions | At ≧ 264 V DC additionally suitable, use fuse. | ||
Nominal input voltage | 110 - 240 V DC 110 - 240 V DC | ||
Rated output voltage | 24 V DC (-1/5%) | ||
Rated output current | A | 5 | |
Setting range for the output voltage | 22 - 28 V DC | ||
Rated output power | W | 120 | |
For use with | easy… MFD… EC4P… XC-CPU… XIOC… PS4… |
General | |||
Standards | EN 61204, 2006/95/EC, 2004/108/EC, EN 50178, EN 60950, UL 60950, UL 508, SELV (EN 60950) | ||
Degree of protection | |||
Enclosures | IP20 | ||
Terminals | IP20 | ||
Protection class | according to EN 61140, Class 1 | ||
Mounting | DIN rail (IEC/EN 60715), snap fixing | ||
Mounting position | Horizontal | ||
Heat dissipation | W | part no. ≦ 15 | |
Efficiency | % | 88 | |
Weight | kg | 0.96 | |
Minimum distance to adjacent devices | mm | horizontal 10, vertical 80 | |
Terminal capacities | |||
Only operate plug-in terminals off load. | |||
Input circuit | |||
Flexible with ferrule | mm2 | 0.2…2.5 (22…14 AWG) | |
Flexible without ferrule | mm2 | 0.2…2.5 (22…14 AWG) | |
Massive | mm2 | 0.2…2.5 (22…14 AWG) | |
Output circuit | |||
Flexible with ferrule | mm2 | 0.12…2.5 (26…14 AWG) | |
Flexible without ferrule | mm2 | 0.12…2.5 (26…14 AWG) | |
Massive | mm2 | 0.12…2.5 (26…14 AWG) | |
Environmental compatibility | |||
Ambient temperature, operation | °C | -25 - +70 | |
Ambient temperature, full load | °C | 0 - +60 (without derating) | |
Ambient temperature, storage | °C | - 40 - + 85 | |
Climatic proofing | to IEC 60068-2-3, 93% at +40 °C, no condensation | ||
Overvoltage category/pollution degree | according to EN 50178; 2 | ||
Climatic class (IEC) | according EN 60721; 3K3 | ||
Vibrations (IEC/EN 60068-2-6) | 1…57 Hz, amplitude ±0.075 mm; 57…100 Hz, 5 g | ||
Mechanical shock resistance (IEC 60068-2-27) | 30 g all directions | ||
Insulation voltage | |||
Inputs/outputs | 3 kV AC (type test), 1.2 kV AC (routine test) | ||
Input | 1.5 kV AC (type test), 1.2 kV AC (routine test) | ||
Output | 350 V AC (routine test) | ||
Electromagnetic compatibility (EMC) | |||
Interference immunity | EN 61000-6-2 | ||
ESD | Air/contact discharge | kV | according to EN 61000-4-2, level 4-8KV/15KV |
RFI | according to EN 61000-4-3, level 3-10 V/m | ||
Burst | according to EN 61000-4-4, level 4-4 KV | ||
Surge | according to EN 61000-4-5, level 4-2KV symmetrical, Level 3-3KV asymmetrical | ||
Cable-born HF | according to EN 61000-4-6, level 3-10 V | ||
Emitted interference | EN 61000-6-3 | ||
Electromagnetic fields | (0.08…1) / (1,4…2) / (2…2,7) GHz | V/m | according to EN 55022, Class B |
Cable-born HF | according to EN 55022, Class B | ||
Input circuit | |||
Supply frequency | |||
Rated value | Hz | 50/60 | |
Range | Hz | 47 - 63 | |
Current consumption | |||
At 110 … 240 V AC | A | Approx. 2.2…1.2 | |
Power consumption | W | Normally 135 | |
Inrush current limiter/i2t (cold start) | ≦ 23 A / ca. 0.9 A2s | ||
Mains failure bridging | ms | typ. ≧ 100 | |
Run-up time after mains voltage applied | ms | Normally ≧ 100 | |
Transient overvoltage protection | Varistors | ||
Internal input fuse (device protection, not accessible) | 4 AT | ||
Discharge current to PE | mA | < 3.5 mA | |
Output circuit | |||
L+, L+, L-, L- | Proof against short-circuit, no-load and overload | ||
Rated output power | W | 120 | |
Rated output current Tu≦ 60 °C | A | 5 | |
Peak output current (power reserves) Tu ≦ 40 °C | A | Normally ≦ 7.25 | |
Derating 60 °C ≦ Tu≦ 70 °C | 2.5 % per Kelvin temperature increase | ||
Control deviation at | |||
Load change 10…90 %, static | Normally | ±0.05 % | |
Load change 10…90 %, dynamic | Normally | ±3 % | |
Controller acting time | ms | Normally 1 | |
Input voltage deviation ±10 % | Normally ±0.05 % | ||
Rise time 10…90 % | ms | Normally ≦ 30 | |
Residual ripple and switching peaks | 20 MHz typically < 50 mVss | ||
Can be switched in parallel | yes, up to 5 devices for redundancy and for power increase, non symetrical current | ||
Series connection capability | yes, for voltage increase (max. 2 off) | ||
Resistance to reverse feed | yes, limited to approx. 35 V AC | ||
Power factor correction (PFC) | Yes | ||
Status indication | OUTPUT OK: LED green | ||
Overload characteristics | → AWA2727-2318 (www.moeller.net/support) | ||
Behaviour on short-circuit | continuously with current limitation | ||
Current limitation at short-circuit | A | Approx. 11 | |
Short-circuit protection | Proof against sustained short circuit | ||
Overload protection | thermal protection | ||
Capacitive load starting | Not restricted | ||
Notes | |||
At U ≧ 264 V DC additionally suitable, use external fuse. |
PLC's (EG000024) / PLC system power supply (EC000599) | |||
Electric engineering, automation, process control engineering / Control / Programmable logic control (SPS) / SPS system power supply (ecl@ss8-27-24-22-09 [AKE532010]) | |||
Input voltage at AC 50 Hz | V | 85 - 264 | |
Input voltage at AC 60 Hz | V | 85 - 264 | |
Input voltage at DC | V | 100 - 350 | |
Type of voltage (input voltage) | AC/DC | ||
Max. input current AC 50 Hz | A | 2.2 | |
Max. input current AC 60 Hz | A | 2.2 | |
Max. input current DC | A | 1.35 | |
Type of output voltage | DC | ||
Output voltage at AC 50 Hz | V | 0 - 0 | |
Output voltage at AC 60 Hz | V | 0 - 0 | |
Output voltage at DC | V | 0 - 0 | |
Max. output current AC 50 Hz | A | 0 | |
Max. output current AC 60 Hz | A | 0 | |
Max. output current DC | A | 5 | |
Redundancy | Yes | ||
Suited for safety functions | Yes | ||
Width | mm | 130 | |
Height | mm | 130 | |
Depth | mm | 57 |
Title: | Size: | Type: |
---|---|---|
PDF CATALOGUE EATON EN.pdf | 51 Mbytes |
No customer reviews for the moment.
Rating: | |
Name: | |
Email: | |
Subject: | |
Text: | |
Do you recommend this product to buy? | |
Add review |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.