T3-3-15523/V/SVB
008865
EATON-MOELLER
1
Main switch, 3 pole, 32 A, rear mounting
Home > EATON - MOELLER
* Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
Product range | Main switch maintenance switch Repair switch | ||
Part group reference | P1 | ||
Notes | Handle SVB(-SW)-P1/M (172840; 172842) only for use with extension shaft P1/P3-400 (172844). | ||
Information about equipment supplied | Auxiliary contact or neutral conductor fitted by user. | ||
Number of poles | 3 pole | ||
Auxiliary contacts | |||
N/O | 0 | ||
N/C | 0 | ||
Degree of Protection | Front IP65 | ||
Design | rear mounting | ||
Contact sequence | |||
Front plate no. | |||
Motor rating AC-23A, 50 - 60 Hz | |||
400 V | P | kW | 15 |
Rated uninterrupted current | Iu | A | 32 |
General | |||
Standards | IEC/EN 60947, VDE 0660, IEC/EN 60204 Switch-disconnector according to IEC/EN 60947-3 | ||
Climatic proofing | Damp heat, constant, to IEC 60068-2-78 Damp heat, cyclic, to IEC 60068-2-30 | ||
Ambient temperature | |||
Open | °C | -25 - +50 | |
Enclosed | °C | -25 - +40 | |
Overvoltage category/pollution degree | III/3 | ||
Rated impulse withstand voltage | Uimp | V AC | 6000 |
Mechanical shock resistance | g | 15 | |
Mounting position | As required | ||
Contacts | |||
Mechanical variables | |||
Number of poles | 3 pole | ||
Auxiliary contacts | |||
N/O | 0 | ||
N/C | 0 | ||
Electrical characteristics | |||
Rated operational voltage | Ue | V AC | 690 |
Rated uninterrupted current | Iu | A | 32 |
Note on rated uninterrupted current !u | Rated uninterrupted current Iuis specified for max. cross-section. | ||
Load rating with intermittent operation, class 12 | |||
AB 25 % DF | x Ie | 2 | |
AB 40 % DF | x Ie | 1.6 | |
AB 60 % DF | x Ie | 1.3 | |
Short-circuit rating | |||
Fuse | A gG/gL | 50 | |
Rated short-time withstand current (1 s current) | Icw | Arms | 640 |
Note on rated short-time withstand current lcw | Current for a time of 1 second | ||
Rated conditional short-circuit current | Iq | kA | 80 |
Switching capacity | |||
cos ϕ rated making capacity as per IEC 60947-3 | A | 320 | |
Rated breaking capacity cos ϕ to IEC 60947-3 | A | ||
230 V | A | 260 | |
400/415 V | A | 300 | |
500 V | A | 290 | |
690 V | A | 250 | |
Safe isolation to EN 61140 | |||
between the contacts | V AC | 440 | |
Current heat loss per contact at Ie | W | 1.8 | |
Lifespan, mechanical | Operations | x 106 | > 0.3 |
Maximum operating frequency | Operations/h | 1200 | |
AC | |||
AC-3 | |||
Rating, motor load switch | P | kW | |
220 V 230 V | P | kW | 7.5 |
400 V 415 V | P | kW | 13 |
500 V | P | kW | 18.5 |
690 V | P | kW | 15 |
Rated operational current motor load switch | |||
230 V | Ie | A | 26.4 |
400V 415 V | Ie | A | 26.4 |
500 V | Ie | A | 23.4 |
690 V | Ie | A | 14.7 |
AC-21A | |||
Rated operational current switch | |||
440 V | Ie | A | 32 |
AC-23A | |||
Motor rating AC-23A, 50 - 60 Hz | P | kW | |
230 V | P | kW | 7.5 |
400 V 415 V | P | kW | 15 |
500 V | P | kW | 18.5 |
690 V | P | kW | 15 |
Rated operational current motor load switch | |||
230 V | Ie | A | 32 |
400 V 415 V | Ie | A | 32 |
500 V | Ie | A | 30 |
690 V | Ie | A | 19.8 |
DC | |||
DC-1, Load-break switches L/R = 1 ms | |||
Rated operational current | Ie | A | 32 |
Voltage per contact pair in series | V | 60 | |
DC-23A, motor load switchL/R = 15 ms | |||
24 V | |||
Rated operational current | Ie | A | 25 |
Contacts | Quantity | 1 | |
48 V | |||
Rated operational current | Ie | A | 25 |
Contacts | Quantity | 2 | |
60 V | |||
Rated operational current | Ie | A | 25 |
Contacts | Quantity | 2 | |
120 V | |||
Rated operational current | Ie | A | 12 |
Contacts | Quantity | 3 | |
Control circuit reliability at 24 V DC, 10 mA | Fault probability | HF | < 10-5, < 1 fault in 100000 operations |
Terminal capacities | |||
Solid or stranded | mm2 | 1 x (1,5 - 6) 2 x (1,5 - 6) | |
Flexible with ferrules to DIN 46228 | mm2 | 1 x (1 - 4) 2 x (1 - 4) | |
Terminal screw | M4 | ||
Tightening torque for terminal screw | Nm | 1.6 | |
Technical safety parameters: | |||
Notes | B10dvalues as per EN ISO 13849-1, table C1 | ||
Rating data for approved types | |||
Contacts | |||
Rated operational voltage | Ue | V AC | 600 |
Rated uninterrupted current max. | |||
Main conducting paths | |||
General use | A | 30 | |
Auxiliary contacts | |||
General Use | IU | A | 10 |
Pilot Duty | A 600 P 600 | ||
Switching capacity | |||
Maximum motor rating | |||
Single-phase | |||
120 V AC | HP | 1 | |
200 V AC | HP | 2 | |
240 V AC | HP | 3 | |
Three-phase | |||
200 V AC | HP | 3 | |
240 V AC | HP | 7.5 | |
480 V AC | HP | 10 | |
600 V AC | HP | 15 | |
Short Circuit Current Rating | SCCR | ||
Basic Rating | kA | 5 | |
max. Fuse | A | 110 | |
High fault rating | kA | 10 | |
max. Fuse | A | 50, Class J | |
Terminal capacity | |||
Solid or flexible conductor with ferrule | AWG | 14 - 8 | |
Terminal screw | M4 | ||
Tightening torque | lb-in | 14.1 |
Product Standards | UL 60947-4-1;CSA - C22.2 No. 60947-4-1-14; CSA-C22.2 No. 94; IEC/EN 60947-3; CE marking | ||
UL File No. | E36332 | ||
UL Category Control No. | NLRV | ||
CSA File No. | 12528 | ||
CSA Class No. | 3211-05 | ||
North America Certification | UL listed, CSA certified | ||
Suitable for | Branch circuits, suitable as motor disconnect | ||
Degree of Protection | IEC: IP65; UL/CSA Type 1 |
Low-voltage industrial components (EG000017) / Switch disconnector (EC000216) | |||
Electric engineering, automation, process control engineering / Low-voltage switch technology / Off-load switch, circuit breaker, control switch / Switch disconnector ([email protected] [AKF060013]) | |||
Version as main switch | Yes | ||
Version as maintenance-/service switch | Yes | ||
Version as safety switch | No | ||
Version as emergency stop installation | No | ||
Version as reversing switch | No | ||
Number of switches | |||
Max. rated operation voltage Ue AC | V | 690 | |
Rated operating voltage | V | 690 - 690 | |
Rated permanent current Iu | A | 32 | |
Rated permanent current at AC-23, 400 V | A | ||
Rated permanent current at AC-21, 400 V | A | 32 | |
Rated operation power at AC-3, 400 V | kW | 13 | |
Rated short-time withstand current lcw | kA | 0.64 | |
Rated operation power at AC-23, 400 V | kW | 15 | |
Switching power at 400 V | kW | 15 | |
Conditioned rated short-circuit current Iq | kA | 80 | |
Number of poles | 3 | ||
Number of auxiliary contacts as normally closed contact | 0 | ||
Number of auxiliary contacts as normally open contact | 0 | ||
Number of auxiliary contacts as change-over contact | 0 | ||
Motor drive optional | No | ||
Motor drive integrated | No | ||
Voltage release optional | No | ||
Device construction | Built-in device fixed built-in technique | ||
Suitable for ground mounting | Yes | ||
Suitable for front mounting 4-hole | No | ||
Suitable for front mounting centre | No | ||
Suitable for distribution board installation | No | ||
Suitable for intermediate mounting | Yes | ||
Colour control element | Other | ||
Type of control element | Other | ||
Interlockable | No | ||
Type of electrical connection of main circuit | Screw connection | ||
Degree of protection (IP), front side | IP65 | ||
Degree of protection (NEMA) |
Title: | Size: | Type: |
---|---|---|
PDF CATALOGUE EATON EN.pdf | 51 Mbytes |
No customer reviews for the moment.
Rating: | |
Name: | |
Email: | |
Subject: | |
Text: | |
Do you recommend this product to buy? | |
Add review |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.