T0-3-8341/EA/SVB 008184 EATON ELECTRIC T0-3-8341 / EA / SVB View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

T0-3-8341/EA/SVB 008184 EATON ELECTRIC T0-3-8341 / EA / SVB

T0-3-8341/EA/SVB

008184

EATON-MOELLER

T0-3-8341 / EA / SVB

More details


Home > EATON - MOELLER

* Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



Delivery program
Assortment
General switches
Maintenance switches
Switches repair
Detector type
P1
Notes
Handle SVB(-SW)-P1/M (172840; 172842) that is allowed only in connection with the shaft P1/P3-400 (172844).
Information on the magnitude of the supply
Auxiliary contact or neutral conductor can then.
Number of poles
3-pole
Auxiliary contacts
Contact NA Zero
NC Zero
Degree of protection
Front IP65
Design
a command returned
Circuit symbol
No. plate front
Rated power of use AC-23A, 50 - 60 Hz
400 V
P kW Fifteen
Rated uninterrupted current
Theu To Thirty two
Technical data
General
Compliance with the standards
IEC/EN 60947, VDE 0660, IEC/EN 60204
Disconnectors, power according to IEC/EN 60947-3
Suitability to the climates
Moist heat, constant according to IEC 60068-2-78
The humid heat, cyclic according to IEC 60068-2-30
Ambient temperature
a day
°C -25 - +50
in case
°C -25 - +40
Overvoltage category/pollution degree
III/3
Rated voltage impulse withstand
Uimp V AC Six thousand
Shock resistance
g Fifteen
Mounting position
optional
Relay contacts
Mechanical values
Number of poles
3-pole
Auxiliary contacts
Contact NA Zero
NC Zero
Electrical parameters
Rated operating voltage
Uand V AC Six hundred ninety
Rated uninterrupted current
Theu To Thirty two
Note on rated uninterrupted current Iu
The rated uninterrupted current Iu is supplied with max. the cross-section.
The load function is intermittent, Class 12
STARTING FROM 25 % AND
x Theand Two
STARTING FROM 40 % AND
x Theand 1.6
STARTING FROM 60 % AND
x Theand 1.3
Resistance to short circuit
with fuses max load.
A gG/gL Fifty
Resistance to short-time current (Current 1-s)
Thecw Toeff Six hundred forty
Note on the current permissible rated short-time current Icw
The current 1 second
Short-circuit current
Iq kA Eighty
Power
Rated closing cos ϕ according to IEC 60947-3
To Three hundred twenty
Interrupting rating cos ϕ to IEC 60947-3
To
230 V
To Two hundred sixty
400/415 V
To Three hundred
500 V
To Two hundred ninety
690 V
To Two hundred fifty
Slicer safe according to EN 61140
between the contacts
V AC Four hundred forty
Losses for the joule effect by contact with Theand
W 1.8
Mechanical life
Maneuvers x 10Six > 0.3
Switching frequency maximum
Operations/h One thousand two hundred
The ac voltage
AC-3
Rated power use switch engine
P kW
220 V 230 V
P kW 7.5
400 V 415 V
P kW Thirteen
500 V
P kW 18.5
690 V
P kW Fifteen
Rated current operation, switches for motors
230 V
Theand To 26.4
400V 415 V
Theand To 26.4
500 V
Theand To 23.4
690 V
Theand To 14.7
AC-21A
The nominal current of use power switches
440 V
Theand To Thirty two
AC-23A
Rated power of use AC-23A, 50 - 60 Hz
P kW
230 V
P kW 7.5
400 V 415 V
P kW Fifteen
500 V
P kW 18.5
690 V
P kW Fifteen
Rated current operation, switches for motors
230 V
Theand To Thirty two
400 V 415 V
Theand To Thirty two
500 V
Theand To Thirty
690 V
Theand To 19.8
Dc voltage
DC-1, break Switches L/R = 1 ms
Nominal operating current
Theand To Thirty two
Voltage on each contact to insert in series
V Sixty
DC-23A, switches, motor L/R = 15 ms
24 V
Nominal operating current
Theand To Twenty five
Contacts
Number One
48 V
Nominal operating current
Theand To Twenty five
Contacts
Number Two
60 V
Nominal operating current
Theand To Twenty five
Contacts
Number Two
120 V
Nominal operating current
Theand To Twelve
Contacts
Number Three
The reliability of the contacts for 24 V DC, 10 mA
Probability of error HF < 10-5, < 1 break on 100000 maneuvers
Connection cross-sections
rigid or semi-rigid
mmTwo 1 x (1.5 - 6)
2 x (1.5 - 6)
Flexible with ferrule according to DIN 46228
mmTwo 1 x (1 - 4)
2 x (1 - 4)
Screw connection
M4
Tightening torque connection screw
Nm 1.6
Technical parameters of safety
Notes
B10dValues according to EN ISO 13849-1, table C1
Power data approved
Relay contacts
Rated operating voltage
Uand V AC Six hundred
Continuous current rating max.
Main circuit
General use
To Thirty
Auxiliary contacts
General Use
TheU To Ten
Pilot Duty
A600
P 600
Power
Maximum engine power
single-phase
120 V AC
HP One
200 V AC
HP Two
240 V AC
HP Three
three-phase
200 V AC
HP Three
240 V AC
HP 7.5
480 V AC
HP Ten
600 V AC
HP Fifteen
Short Circuit Current Rating
SCCR
Basic Rating
kA Five
max. Fuse
To One hundred ten
High fault rating
kA Ten
max. Fuse
To 50, Class J
Connection cross-sections
rigid or flexible with ferrule
AWG 14 - 8
Screw connection
M4
Tightening torque
lb-in 14.1
Approvals
Product Standards UL 60947-4-1;CSA - C22.2 No. 60947-4-1-14; CSA-C22.2 No. 94; IEC/EN 60947-3; CE marking
UL File No. E36332
UL Category Control No. NLRV
CSA File No. Twelve thousand five hundred twenty eight
CSA Class No. 3211-05
North America Certification UL listed, CSA certified
Suitable for Branch circuits, suitable as motor disconnect
Degree of Protection IEC: IP65; UL/CSA Type 1
Technical data according to ETIM 7.0(show characteristics)(hide features)
electrical equipment in low-voltage (EG000017) / load break switch (EC000216)
The Technique Of Ar., Elem., Energy, Tech. Comm., Network And Proc. Pipeline / Technology, Low Voltage Switch / Load Switch, Disconnect switch, Control Switch / switch Disconnector compact ([email protected] [AKF060013])
execution as the main switch
yes
running as a switch maintenance/repair
yes
running as a safety switch
no
run as the emergency stop device
no
running as an inverter
no
number of switches
max. operating voltage nominal Ue to AC
V Six hundred ninety
operating voltage nominal
V 690 - 690
nominal continuous current Iu
To Thirty two
nominal continuous current at AC-23, 400V
To
nominal continuous current for AC-21, 400 V
To Thirty two
operating power rated for AC-3, 400 V
kW Thirteen
resistance to short-time current Icw
kA 0.64
operating power rated for AC-23, 400V
kW Fifteen
power at 400 V
kW Fifteen
short-circuit current the rated conditional Iq
kA Eighty
number of poles
Three
number of auxiliary contacts, the contacts of the rest
Zero
number of auxiliary contacts, closing contacts
Zero
number of auxiliary contacts, power inverters
Zero
motor drive optional
no
motor drive integrated
no
auxiliary voltage optional
no
the type of construction of the device
recessed luminaire, a technique for fixed installation
suitable for fixing to the ground
yes
suitable for mounting front 4 holes
no
suitable for fixing to front center
no
suitable for mounting on the distributor
no
suitable for building intermediate
yes
the color of the drive element
other
the execution of the drive element
other
lockable
no
type of connection circuit in the main electrical
screw fitting
degree of protection (IP), front side
IP65
type of protection (NEMA)

Datasheet - PDF

Title: Size: Type:
PDF CATALOGUE EATON EN.pdf 51 Mbytes

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.