ANUNCIAR
LSE-02 266122 Y7-266122 EATON ELECTRIC Safety position switch, electrically adjustable, 2 N/C, cat .3 View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

LSE-02 266122 Y7-266122 EATON ELECTRIC Safety position switch, electrically adjustable, 2 N/C, cat .3

LSE-02

266122

Y7-266122

EATON-MOELLER

2

Safety position switch, electrically adjustable, 2 N/C, cat .3

LSE-02

Eaton Moeller® series LSE Safety position switch, LSE, Position switch with electronically adjustable operating point, Basic device, expandable, 2 NC, Yellow, Insulated material, Cage Clamp, -25 - +70 °C

Safety position switch, Basic function: Position switches, Safety position switches, Part group reference: LSE, Product range: Position switch with electronically adjustable operating point, Degree of Protection: IP66, IP67, Features: Basic device, expandable, Ambient temperature: -25 - +70 °C, Description: Visual status indication, comparable with positive opening function, Device goes into safe state on high interference., Can be used in safety circuits, partly short-circuit proof, Restart after reset, Individual operating point adjustment, Contacts N/C = Normally closed: 2 NC, Ue= 12 - 30 V DC, Color Enclosure covers: Yellow , Housing: Insulated material, Connection type: Cage Clamp, Cage-Clamp is a registered trademark of Wago Kontakttechnik, 32432 Minden, Germany., Accessories for t

More details


Sensors > End switch

Position Switches

Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER

Total: $141.23
Unit price: $70.62
This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Related products

Best sellers

More info



General specifications

Product Name
Eaton Moeller® series LSE Safety position switch
Catalog Number
266122
Model Code
LSE-02
EAN
4015082661229
Product Length/Depth
33.5 mm
Product Height
76.5 mm
Product Width
31 mm
Product Weight
0.048 kg
Compliances
CE Marked
Certifications
CSA Std. C22.2 No. 14
EN 60947-5
IEC 60947-5
UL 508
CE
CSA
UL
CSA Class No.: 3211-03
IEC/EN 61000-4
UL Category Control No.: NKCR
CSA-C22.2 No. 14
IEC/EN 60947
IEC/EN 60947-5
CSA File No.: 012528
UL File No.: E29184

Product specifications

Type
Safety position switch
Voltage rating
12-30 Vdc
Features
Expandable
Air discharge
8 kV, according to IEC/EN 61000-4-2, Level 3, ESD
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
Electric connection type
Cable entry metrical
Enclosure material finishing
Other
Fitted with:
Status indication
Operating frequency
3000 Operations/h
Pollution degree
3
Burst impulse
2 kV, Signal cable, according to IEC/EN 61000-4-4, Level 3
2 kV, Supply cable, according to IEC/EN 61000-4-4, Level 3
Actuator alignment
Roller cam straight
Climatic proofing
Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30
Enclosure material
Plastic
Insulated material
Enclosure type
Cuboid
Rated operational current (Ie) at DC-1, 12 V
0.015 A
Rated operational current (Ie) at DC-1, 24 V
18 A
Rated operational current (Ie) at DC-13, 125 V
0 A
Rated operational current (Ie) at DC-13, 220 V, 230 V
0 A
Rated operational current (Ie) at DC-13, 24 V
0.2 A
Rated operational current for specified heat dissipation (In)
0.2 A
Rated switching distance (Sn) - max
5.5 mm
Rated switching distance (Sn) - min
0.5 mm
Sensor height
61 mm
Sensor length
33.5 mm
Static heat dissipation, non-current-dependent Pvs
0.4 W
Switching hysteresis of Sn
0.4 %
Width sensor
31 mm
Product category
Position switch
Action
2021118113756-Mechanical Limit Switches.xlsm-Data
Connection
Cage clamp
Contact configuration
2 NC
Enclosure color
Yellow Cover
Actuating force at beginning/end of stroke
3.5 N/8.0 N
Explosion safety category for dust
None
Indication
Visual status indication
Explosion safety category for gas
None
Actuator type
Plunger
Actuating torque of rotary drives
0.2 Nm
Ambient operating temperature - max
70 °C
Ambient operating temperature - min
-25 °C
Diameter sensor
0 mm
Equipment heat dissipation, current-dependent Pvid
0 W
Heat dissipation capacity Pdiss
0 W
Heat dissipation per pole, current-dependent Pvid
0.15 W
Number of contacts (change-over contacts)
0
Number of contacts (normally closed contacts)
2
Number of contacts (normally open contacts)
0
Number of safety auxiliary contacts
0
Operating temperature - max
40 °C
Operating temperature - min
-25 °C
Rated operational current (Ie) at AC-15, 125 V
0 A
Rated operational current (Ie) at AC-15, 220 V, 230 V, 240 V
0 A
Rated operational current (Ie) at AC-15, 24 V
0 A
Functions
Output electronic
Mounting position
As required
Material
Plastic housing
Contact discharge
4 kV, according to IEC/EN 61000-4-2, Level 3, ESD
Overvoltage category
III
Connection type
Cage Clamp
Temperature resistance
100 °C, Contact temperature of roller head
Surge rating
0.5 kV, Power pulses (Surge), according to IEC/EN 61000-4-5, EMC
Degree of protection
IP66/IP67
NEMA Other
Interface type
None
Switch function type
Slow-action switch
Electromagnetic fields
10 V/m (according to IEC EN 61000-4-3)
Immunity to line-conducted interference
10 V (according to IEC/EN 61000-4-6)
Lifespan
3,000,000 electrical Operations
3,000,000 mechanical Operations
Rated operational voltage
12 - 30 V DC
Repetition accuracy
0.02 mm (Contacts/switching capacity)
Shock resistance
30 g, Basic unit, Mechanical, Half-Sinusoidal shock 20 ms
Suitable for
Safety functions
Operating speed
For angle of actuation α = 0°/30°
Max. 1/0.5 m/s (with DIN cam, mechanical actuation)
Rated breaking capacity
0.019 A (30 V DC)
Terminal capacity (flexible with ferrule)
1 x (0.5 - 1.5) mm²
Terminal capacity (solid)
1 x (0.5 - 2.5) mm²

ETIM for 266122 Sensors (EC000030)
Feature Name Feature Value
Width sensor (EF007094) 31 mm
Diameter sensor (EF007111) 0 mm
Height of sensor (EF007283) 61 mm
Length of sensor (EF007334) 33.5 mm
Rated operation current Ie at AC-15, 24 V (EF007084) 0 A
Rated operation current Ie at AC-15, 125 V (EF007082) 0 A
Rated operation current Ie at AC-15, 230 V (EF001385) 0 A
Rated operation current Ie at DC-13, 24 V (EF007087) 0.2 A
Rated operation current Ie at DC-13, 125 V (EF007085) 0 A
Rated operation current Ie at DC-13, 230 V (EF001386) 0 A
Switching function (EF000189) Slow-action switch
Switching function latching (EF007447) No
Output electronic (EF006987) Yes
Forced opening (EF006694) No
Number of safety auxiliary contacts (EF006940) 0
Number of contacts as normally closed contact (EF008255) 2
Number of contacts as normally open contact (EF008256) 0
Number of contacts as change-over contact (EF008257) 0
Type of interface (EF006977) None
Type of interface for safety communication (EF003956) None
Construction type housing (EF004008) Cuboid
Housing material (EF001596) Plastic
Coating housing (EF001601) Other
Type of control element (EF006976) Plunger
Alignment of the control element (EF008793) Roller cam straight
Type of electric connection (EF003961) Cable entry metrical
With status indication (EF001602) Yes
Suitable for safety functions (EF001597) Yes
Explosion safety category for gas (EF003997) None
Explosion safety category for dust (EF003998) None
Ambient temperature during operating (EF007515) -25 °C
Degree of protection (IP) (EF005474) IP66/IP67
Degree of protection (NEMA) (EF011959) Other

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.