SWD4-50LR8-24 116030 4519787 EATON ELECTRIC Round cable, SmartWire-DT, 50m, 8-Pole, 8mm View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

SWD4-50LR8-24 116030 4519787 EATON ELECTRIC Round cable, SmartWire-DT, 50m, 8-Pole, 8mm

SWD4-50LR8-24

116030

4519787

EATON-MOELLER

Round cable, SmartWire-DT, 50m, 8-Pole, 8mm

SWD4-50LR8-24

More details


Smartwire Darwin

* Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER

Total price: $244.85
Unit price: $244.85

Quantity Price
1+$244.85
2+$216.62
3+$216.62
4+$216.62
*This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Often bought together

More info



Round cable, SmartWire-DT, 50m, 8-Pole, 8mm
50 m, 8-pole, 8 mm diameter SmartWire-DT round cable for connecting the SmartWire-DT cards outside of the control panel, not assembled, for connection to SWD adapter SWD4-8FRF-10 as well as PCBs M22-SWD-Ix.

General specifications
Product name
Eaton SWD4 Accessory Round cable
Part no.
SWD4-50LR8-24
EAN
4015081157709
Product Length/Depth
270 millimetre
Product height
100 millimetre
Product width
130 millimetre
Product weight
4.03 kilogram
Certifications
CSA Class No.: 3211-07
UL File No.: E29184
UL Category Control No.: NKCR
CSA
UL
CSA File No.: 2324643
Product Tradename
SWD4
Product Type
Accessory
Product Sub Type
Round cable
Catalog Notes
Condensation: permissible
Features & Functions
Features
Oil resistant (acc. EN 60811-404)
Oil resistant (acc. IEC 60811-404)
UV resistant
Functions
For connection to SWD4-8FRF-10 SWD cable adapter and M22-SWD-Ix series printed circuit boards
General information
Cable length
50 m
Number of Poles
Eight-pole
Outer diameter - approximate
8.2 mm
Outer sheath material
Polyvinyl chloride (PVC)
Permitted bending radius, moving application with free movement - min
120 mm
Product category
SmartWire-DT accessories
Suitable as
Signaling cable
Climatic environmental conditions
Ambient operating temperature - min
-25 °C
Ambient operating temperature - max
70 °C
Safety
Flame retardant
In accordance with EN 60332-1-2
Design verification
Equipment heat dissipation, current-dependent Pvid
0 W
Heat dissipation capacity Pdiss
0 W
Heat dissipation per pole, current-dependent Pvid
0 W
Rated operational current for specified heat dissipation (In)
0 A
Static heat dissipation, non-current-dependent Pvs
0 W
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
Meets the product standard's requirements.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

Technical data ETIM 9.0

Cables (EG000001) / Data and communication cable (EC003249)
Electric engineering, automation, process control engineering / Cable, wire / Communication cable / Data and communication cable (copper) (ecl@ss13-27-06-18-01 [AKE197019])
Cable type
Other
Duplex
No
Conductor material
Other
Conductor surface
Bare
Diameter conductor
1.5 mm
Nominal cross section conductor
0.5 mm²
AWG size
20
Conductor category
Class 2 = stranded
Number of cores
8
Number of stranding elements
4
Stranding element
Pairs
Material core insulation
Other
Specification core insulation
Other
Core identification according to HD 308 S2
No
Core identification
Colour
Screen over stranding element
Foil
Stranding
Bundle
Screen over stranding
None
Longitudinal water blocking cable
No
Radial water blocking cable
No
Suitable for underground installation
No
Approved type of underground installation
Other
Protective sheath
Other
Material outer sheath
Polyvinyl chloride (PVC)
Specification material outer sheath
Polypropylene (PP)
Colour outer sheath
Green
Number of sheath layers
0
Armouring/reinforcement
None
Material armouring
Other
Cable geometry
Round
Flame retardant according to IEC 60332-1-2
No
Flame retardant according to IEC 60332-3-21 (Cat A F/R)
No
Flame retardant according to IEC 60332-3-22 (Cat A)
No
Flame retardant according to IEC 60332-3-23 (Cat B)
No
Flame retardant according to IEC 60332-3-24 (Cat C)
No
Flame retardant according to IEC 60332-3-25 (Cat D)
No
Low smoke according to EN IEC 61034-2
No
Halogen free according to EN IEC 60754-1
No
Halogen free according to EN IEC 60754-2
No
Halogen free according to EN IEC 60754-3
No
Reaction-to-fire according to EN 13501-6: Class
None
Reaction-to-fire according to EN 13501-6: Smoke production
None
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles
None
Reaction-to-fire according to EN 13501-6: Acidity
None
Circuit integrity according to IEC 60331-23
No
Oil resistant according to EN IEC 60811-404
Yes
Outer diameter approx.
8.2 mm
Min. permitted bending radius, moving application with forced guidance
120 mm
Min. permitted bending radius, moving application/free movement
120 mm
Min. permitted bending radius, stationary application/permanent installation
120 mm
Permitted cable outer temperature during assembling/handling
-10 - 80 °C
Permitted cable outer temperature after assembling without vibration
-20 - 80 °C
Category
Other
NVP value
66.5 %
UV resistant
Yes
Certified for shipboard application
No
Segregation class according to EN 50174-2
Suitable as telephone cable
No
Suitable as computer data cable
No
Suitable as signalling cable
Yes
Suitable for use as security alarm cable
No
Drain wire
No
With rip cord
No
Cable width approx.
8.2 mm
Cable height approx.
100 mm
Weight
kg/km
Characteristic impedance
100 Ohm
Max. tensile strength during installation
kN
Nominal voltage U
24 V
With rodent protection
No
Circuit integrity according to DIN 4102-12
Compatible with Grade2TV according to XP-C 90-483
No
Compatible with Grade3TV according to XP-C 90-483
No
Cable type according to BS 4737-3.30
Rip cord colour according to BS 4737-3.30
Compliant with BT (British Telecom) specification

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.