PKE65/AK/XTUW-32-SP 170483 XTPE032DCSSP EATON ELECTRIC Type AND CMC, 8 32, standard, lockable knob View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

PKE65/AK/XTUW-32-SP 170483 XTPE032DCSSP EATON ELECTRIC Type AND CMC, 8 32, standard, lockable knob

PKE65/AK/XTUW-32-SP

170483

XTPE032DCSSP

EATON-MOELLER

Type AND CMC, 8 - 32, standard, lockable knob

PKE65/AK/XTUW-32-SP

Motor-protective circuit-breaker, Type E DOL starters (complete devices), Electronic, 8 - 32 A, Turn button, Screw connection, North America

More details


Low-voltage industrial components > Motor protection circuit-breaker

Electronic Circuit Breakers

* Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER

Total price: $418.69
Unit price: $418.69

*This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



Motor-protective circuit-breaker, Type E DOL starters (complete devices), Electronic, 8 - 32 A, Turn button, Screw connection, North America
Type E complete device as per UL 508 ((self-protected) combination motor controller), consisting of PKE65 basic device and PKE-XTU-32 trip block, with lockable knob and corresponding extension terminal for UL, can be used for motors with up to 20 horse power (FLA = 27 A / 480 V) or 25 horse power (FLA = 27 A / 600 V), short circuit current rating to UL: 65 kA (480 V/ 277 V) or 25 kA (600 V/ 347 V), electronic wide-range overload protection, high short-circuit breaking capacity to IEC (80 kA / 400 V), can be used as a type F motor starter (combination motor controller) in combination with DILM17 to DILM72 contactors.

Delivery program

Basic function
Type E DOL starters (complete devices)
Connection technique
Screw terminals
Components for
North America
Connection to SmartWire-DT
no
Maximum motor rating
AC HP = PS200 V 208 V
7.5 HP
AC HP = PS230 V 240 V
7.5 HP
AC HP = PS460 V 480 V
20 HP
AC HP = PS575 V 600 V
25 HP
Short Circuit Current Rating
240 V
65 kA
480 Y
277 V
65 kA
600 Y
347 V
25 kA
Setting range
Setting range of overload releases[Ir]
8 - 32 A
Motor-protective circuit-breakers
PKE65/AK/XTUW-32 Type
Extension terminal
BK50/3-PKZ4-E
Notes

The type E DOL starter (without protection) consists of a PKE65 motor-protective circuit-breaker with AK-PKZ0 and a BK50/3-PKZ4-E extension terminal.

Technical data

General
Standards
IEC/EN 60947-4-1, VDE 0660, UL, CSA
Mounting position
2115DRW-5
Ambient temperature
-25 - +55
Main conducting paths
Rated impulse withstand voltage [Uimp]
6000 V AC
Overvoltage category/pollution degree
III/3
Rated operational voltage [Ue]
208 - 600 V
Rated operational currentOpen, 3-pole: 50 – 60 Hz380 V 400 V [Ie]
32 A
AC-4 cycle operationMinimum current flow times
500 (Class 5)
700 (Class 10)
900 (Class 15)
1000 (Class 20) ms
AC-4 cycle operationMinimum cut-out periods
500 ms
AC-4 cycle operationNote
In AC-4 cycle operation, going below the minimum current flow time can cause overheating of the load (motor).
For all combinations with an SWD activation, you need not adhere to the minimum current flow times and minimum cut-out periods. ms
Additional technical data
Motor protective circuit breaker PKZM0, PKE
PKE motor-protective circuit-breaker, see motor-protective circuit-breaker product group
DILM contactorsCurrent heat lossCurrent heat loss at Ieto AC-3/400 V
5.4 W
Rating data for approved types
Switching capacityMaximum motor ratingThree-phase200 V
208 V
7.5 HP
Switching capacityMaximum motor ratingThree-phase230 V
240 V
7.5 HP
Switching capacityMaximum motor ratingThree-phase460 V
480 V
20 HP
Switching capacityMaximum motor ratingThree-phase575 V
600 V
25 HP
Short Circuit Current Rating, type E240 V
65 kA
Short Circuit Current Rating, type E480 Y / 277 V
65 kA
Short Circuit Current Rating, type E600 Y / 347 V
25 kA

Design verification as per IEC/EN 61439

Technical data for design verification
Rated operational current for specified heat dissipation [In]
32 A
Heat dissipation per pole, current-dependent [Pvid]
1.8 W
Equipment heat dissipation, current-dependent [Pvid]
5.4 W
Static heat dissipation, non-current-dependent [Pvs]
0 W
Heat dissipation capacity [Pdiss]
0 W
Operating ambient temperature min.
-25 °C
Operating ambient temperature max.
+55 °C
IEC/EN 61439 design verification
10.2 Strength of materials and parts10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of ASSEMBLIES
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9 Insulation properties10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9 Insulation properties10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9 Insulation properties10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

Technical data ETIM 7.0

Low-voltage industrial components (EG000017) / Motor protection circuit-breaker (EC000074)
Electric engineering, automation, process control engineering / Low-voltage switch technology / Circuit breaker (LV < 1 kV) / Motor protection circuit-breaker ([email protected] [AGZ529016])
Overload release current setting
8 - 32 A
Adjustment range undelayed short-circuit release
0 - 0 A
With thermal protection
Yes
Phase failure sensitive
Yes
Switch off technique
Electronic
Rated operating voltage
690 - 690 V
Rated permanent current Iu
32 A
Rated operation power at AC-3, 230 V
7.5 kW
Rated operation power at AC-3, 400 V
15 kW
Type of electrical connection of main circuit
Screw connection
Type of control element
Turn button
Device construction
Built-in device fixed built-in technique
With integrated auxiliary switch
No
With integrated under voltage release
No
Number of poles
3
Rated short-circuit breaking capacity lcu at 400 V, AC
80 kA
Degree of protection (IP)
IP20
Height
162 mm
Width
55 mm
Depth
198 mm

Approvals

Product Standards
UL60947-4-1A; CSA-C22.2 No. 14-10; IEC60947-4-1; CE marking
UL File No.
E123500
UL Category Control No.
NKJH
CSA File No.
12528
CSA Class No.
3211-08
North America Certification
UL listed, CSA certified
Specially designed for North America
Yes

Characteristics

Characteristic curve
1210DIA-67

Dimensions

1210DIM-75

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.