Product successfully added to your shopping cart
M30I-FWRS-MS8
188163
Y7-188163
EATON-MOELLER
1
Key-operated push-buttons, flat front, not master-key system compatible, 2 positions, maintained, MS8
M30I-FWRS-MS8
Eaton Moeller® series M30 Key-operated actuator, Flat Front, maintained, 2 positions, MS8, Key withdrawable: 0, I, Bezel: stainless steel
Key-operated actuator, Product range: RMQ-Titan, Single unit, Design: Key operation lock mechanism, maintained, Not suitable for master key systems, 2 positions, Lock mechanism: MS8, I, Degree of Protection: IP64, Front ring stainless steel, Connection to SmartWire-DT: yes, with SWD-RMQ connections, Front dimensions: Ø 36mm, Instructions: Stay-put/spring-return function, can be changed with coding parts M22-XC-Y, Key withdraw convertible with coding adapters M22-XC-..., With 1 key, Standards: IEC/EN 60947, VDE 0660, Degree of Protection: IP64
Low-voltage industrial components > Front element for selector switch
Auxiliary Control and Signalling Elements
Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| Product Name | Eaton Moeller® series M30 key-operated actuator |
| Catalog Number | 188163 |
| Model Code | M30I-FWRS-MS8 |
| EAN | 4015081858323 |
| Product Length/Depth | 36 mm |
| Product Height | 67 mm |
| Product Width | 46 mm |
| Product Weight | 0.06 kg |
| Certifications | VDE 0660 IEC/EN 60947 CSA file No. 012528 CSA Class No.: 3211-03 DNV UL File No.: E29184 GL IEC/EN 60947-5 UL 508 CSA-C22.2 No. 14-05 CSA-C22.2 No. 94-91 CE marking UL Category Control No.: NKCR UL Listed CSA certified |
| Type | Key-operated button |
| Accessories | 1 key included with supplied equipment. |
| Actuator color | Black |
| Actuator function | Key withdrawable in position 1 Switching function latching Key withdrawable in position 0 Maintained |
| 10.10 Temperature rise | Not applicable. |
| 10.11 Short-circuit rating | Is the panel builder's responsibility. The specifications for the switchgear must be observed. |
| 10.12 Electromagnetic compatibility | Is the panel builder's responsibility. The specifications for the switchgear must be observed. |
| 10.13 Mechanical function | The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
| 10.2.2 Corrosion resistance | Meets the product standard's requirements. |
| 10.2.3.1 Verification of thermal stability of enclosures | Meets the product standard's requirements. |
| 10.2.3.2 Verification of resistance of insulating materials to normal heat | Meets the product standard's requirements. |
| 10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects | Meets the product standard's requirements. |
| 10.2.4 Resistance to ultra-violet (UV) radiation | Please enquire |
| 10.2.5 Lifting | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.2.6 Mechanical impact | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.2.7 Inscriptions | Meets the product standard's requirements. |
| 10.3 Degree of protection of assemblies | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.4 Clearances and creepage distances | Meets the product standard's requirements. |
| 10.5 Protection against electric shock | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.6 Incorporation of switching devices and components | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.7 Internal electrical circuits and connections | Is the panel builder's responsibility. |
| 10.8 Connections for external conductors | Is the panel builder's responsibility. |
| 10.9.2 Power-frequency electric strength | Is the panel builder's responsibility. |
| 10.9.3 Impulse withstand voltage | Is the panel builder's responsibility. |
| 10.9.4 Testing of enclosures made of insulating material | Is the panel builder's responsibility. |
| Fitted with: | Front ring |
| Operating frequency | 100 Operations/h |
| Pollution degree | 3 |
| Climatic proofing | Damp heat, cyclic, to IEC 60068-2-30 Damp heat, constant, to IEC 60068-2-78 |
| Connection to SmartWire-DT | Yes With SWD-RMQ connections |
| Actuator type | Key |
| Ambient operating temperature - max | 70 °C |
| Ambient operating temperature - min | -25 °C |
| Equipment heat dissipation, current-dependent Pvid | 0 W |
| Force for positive opening - min | 0 N |
| Heat dissipation capacity Pdiss | 0 W |
| Heat dissipation per pole, current-dependent Pvid | 0 W |
| Opening diameter | 30 mm |
| Operating torque | 0.5 Nm |
| Rated operational current for specified heat dissipation (In) | 0 A |
| Static heat dissipation, non-current-dependent Pvs | 0 W |
| Switching angle | 60 ° |
| Bezel color | Stainless steel |
| Shock resistance | Mechanical, According to IEC/EN 60068-2-27 15 g, Mechanical, According to IEC/EN 60068-2-27, Sinusoidal shock 11 ms |
| Key code | MS8 |
| Bezel material | Metal |
| Design | Key operation lock mechanism Flat front |
| Mounting position | As required |
| Overvoltage category | III |
| Degree of protection | NEMA 4X, 13 |
| Degree of protection (front side) | IP66 |
| Functions | Stay-put/spring-return function, can be changed with coding parts M22-XC-Y |
| Indicator color | Other |
| Lens type | Round |
| Lifespan, mechanical | 100,000 Operations |
| Number of switch positions | 2 |
| Size | Front dimensions: Ø 36 mm |
| Product category | RMQ-Titan |
| Feature Name | Feature Value |
|---|---|
| Number of switch positions (EF000231) | 2 |
| Type of control element (EF006976) | Key |
| Suitable for lighting (EF001142) | No |
| Colour control element (EF007167) | Black |
| Colour indicator light cap (EF007165) | Other |
| Construction type lens (EF006253) | Round |
| Hole diameter (EF000079) | 30 mm |
| Width opening (EF004565) | 0 mm |
| Height opening (EF004778) | 0 mm |
| Switching function latching (EF007447) | Yes |
| Spring-return (EF001407) | No |
| With front ring (EF006014) | Yes |
| Material front ring (EF005972) | Metal |
| Colour front ring (EF002429) | Stainless steel |
| Degree of protection (IP), front side (EF003118) | IP66 |
| Degree of protection (NEMA) (EF011959) | 4X, 13 |
| Title: | Size: | Type: |
|---|---|---|
| PDF EATON COMMAND INDICATION EN.pdf | 24 Mbytes |
|
| PDF CATALOGUE EATON EN .pdf | 38 Mbytes |
|
| M30I-FWRS-MS8 Y7-188163 188163 ES_182922.pdf | 3 Mbytes |
![]() |
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.