SPX250A0-5A2N1 129602 Y7-129602 EATON ELECTRIC Variable frequency drive SVX 3-/3-phase 250 kW 690 V degree o.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

SPX250A0-5A2N1 129602 Y7-129602 EATON ELECTRIC Variable frequency drive SVX 3-/3-phase 250 kW 690 V degree o..

SPX250A0-5A2N1

129602

Y7-129602

EATON-MOELLER

Variable frequency drive SVX 3-/3-phase 250 kW 690 V; degree of protection IP00; integrated EMC filter

SPX250A0-5A2N1

Variable frequency drive, 600 V AC, 3-phase, 250 kW, IP00, OLED display, FR10

More details


Low-voltage industrial components > Frequency converter less than 1 kV

Eaton Frequency Converters

Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER

Total: $41,311.39
Unit price: $41,311.39
This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



Variable frequency drive, 600 V AC, 3-phase, 250 kW, IP00, OLED display, FR10
Variable frequency drive, Part group reference (e.g. DIL): SPX, Rated operational voltage: Ue = 600 V AC, 3-phase, 690 V AC, 3-phase, Output voltage with Ve: U2 = 600 V AC, 3-phase, 690 V AC, 3-phase, Mains voltage (50/60Hz): ULN = 525 (-15%) - 690 (±10%) V, Rated operational current At 150% overload: Ie = 261 A, Rated operational current At 110% overload: Ie = 325 A, Note: Overload cycle for 60 s every 600 s, Assigned motor rating Note: For AC motors with internal and external ventilation with 50 Hz / 60 Hz, Overload cycle for 60 s every 600 s, at 690 V, 50 Hz, Assigned motor rating 150 % Overload: P = 250 kW, 110 % Overload: P = 315 kW , 150 % Overload: IM = 253 A, 110 % Overload: IM = 316 A, Assigned motor rating Note: at 690 V, 60 Hz, Assigned motor rating 150 % Overload: P = 250 HP, 110 % Overload: P = 300 HP, Assigned motor rating 150 % Overload: IM = 211 A, 110 % Overload: IM = 251 A, Degree of Protection: IP00, Fieldbus connection (optional): PROFIBUS-DP, LonWorks, CANopen®, DeviceNet, Modbus-TCP, BACnet/IP, Fitted with: OLED display, Frame size: FR10, Standards: Specification for general requirements: IEC/EN 61800-2, EMC requirements: IEC/EN 61800-3, Safety requirements: IEC/EN 61800-5-1

General specifications
Product name
Eaton SPX variable frequency drive
Part no.
SPX250A0-5A2N1
EAN
4015081269297
Product Length/Depth
1165 millimetre
Product height
506 millimetre
Product width
500 millimetre
Product weight
275 kilogram
Certifications
IEC/EN61800-3
UL
CUL
Specification for general requirements: IEC/EN 61800-2
RoHS, ISO 9001
RCM
UL 508C
UL report applies to both US and Canada
CE
UL Category Control No.: NMMS, NMMS2, NMMS7. NMMS8
Certified by UL for use in Canada
CSA Class No.: 3211-06
IEC/EN61800-5
UL File No.: E134360
IEC/EN 61800-3
CSA-C22.2 No. 14
Safety: EN 61800-5-1: 2003
DNV
Product Tradename
SPX
Product Type
Variable frequency drive
Product Sub Type
None
Catalog Notes
Assigned motor rating: For AC motors with internal and external ventilation with 50 Hz / 60 Hz
Assigned motor rating: Overload cycle for 60 s every 600 s
General information
Degree of protection
IP00
NEMA Other
Electromagnetic compatibility
1st and 2nd environments (according to EN 61800-3)
Fitted with:
IGBT inverter
Internal DC link
Control unit
OLED display
PC connection
Frame size
FR10
Functions
4-quadrant operation possible
Mounting position
Vertical
Product Category
Variable frequency drives
Protection
Finger and back-of-hand proof, Protection against direct contact (BGV A3, VBG4)
Radio interference class
C2, C3: depending on the motor cable length, the connected load, and ambient conditions. External radio interference suppression filters (optional) may be necessary.
Suitable for
Branch circuits, (UL/CSA)
Climatic environmental conditions
Altitude
Above 1000 m with 1 % performance reduction per 100 m
Max. 1000 m
Max. 3000 m
Ambient operating temperature - min
-10 °C
Ambient operating temperature - max
40 °C
Ambient operating temperature at 150% overload - min
-10 °C
Ambient operating temperature at 150% overload - max
40 °C
Ambient storage temperature - min
-40 °C
Ambient storage temperature - max
70 °C
Climatic proofing
< 95 % relative humidity, no condensation, no corrosion, no dripping water
Main circuit
Mains voltage - min
525 V
Mains voltage - max
690 V
Operating mode
Optional: Vector control with feedback (CLV)
Sensorless vector control (SLV)
U/f control
Output frequency - min
0 Hz
Output frequency - max
320 Hz
Output voltage (U2)
690 V AC, 3-phase
600 V AC, 3-phase
Rated control supply voltage
10 V DC (Us, max. 10 mA)
Rated frequency - min
45 Hz
Rated frequency - max
66 Hz
Rated operational current (Ie) at 110% overload
325 A
Rated operational current (Ie) at 150% overload
261 A
Rated operational power at 690 V, 50 Hz, 3-phase
250 kW
Rated operational power at 690 V, 50 Hz, 3-phase, 110% overload
315 kW
Rated operational voltage
600 V AC, 3-phase
690 V AC, 3-phase
Resolution
0.01 Hz (Frequency resolution, setpoint value)
Supply frequency
50/60 Hz
Switching frequency
1.5 kHz, 1 - 6 kHz adjustable, fPWM, Power section, Main circuit
System configuration type
AC supply systems with earthed center point
Voltage rating - max
690 V AC
Motor rating
Assigned motor current IM at 690 V, 50 Hz, 110% overload
316 A
Assigned motor current IM at 690 V, 50 Hz, 150% overload
253 A
Assigned motor current IM at 690 V, 60 Hz, 110% overload
251 A
Assigned motor current IM at 690 V, 60 Hz, 150% overload
211 A
Assigned motor power at 690 V, 60 Hz, 3-phase
250 HP
Assigned motor power at 690 V, 60 Hz, 3-phase, 110 % overload
300 HP
Control circuit
Number of inputs (analog)
2
Number of inputs (digital)
6
Number of outputs (analog)
1
Number of outputs (digital)
1
Number of relay outputs
2 (parameterizable, N/O, 8 A (24 V DC) / 8 A (250 V AC) / 0,4 A (125 V DC))
Rated control voltage (Uc)
24 V DC (external, max. 250 mA)
Communication
Communication interface
CANopen®, optional
PROFIBUS-DP
DeviceNet, optional
LonWorks, optional
BACnet/IP, optional
Modbus-TCP, optional
BACnet MS/TP, optional
EtherCAT, optional
Ethernet IP, optional
Modbus-RTU, optional
PROFINET, optional
Connection to SmartWire-DT
No
Protocol
PROFIBUS
Other bus systems
DeviceNet
LON
CAN
TCP/IP
Data-Highway
Design verification
Equipment heat dissipation, current-dependent Pvid
6250 W
Heat dissipation capacity Pdiss
0 W
Heat dissipation per pole, current-dependent Pvid
0 W
Rated operational current for specified heat dissipation (In)
261 A
Static heat dissipation, non-current-dependent Pvs
0 W
Heat dissipation details
Operation (with 150 % overload)
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.