DA1-327D0FB-A6SN 169166 EATON ELECTRIC PowerXL Drive Series DA1 View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

DA1-327D0FB-A6SN 169166 EATON ELECTRIC PowerXL Drive Series DA1

DA1-327D0FB-A6SN

169166

EATON-MOELLER

PowerXL Drive - Series DA1

More details


Home > EATON - MOELLER

Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



Range of delivery
Range
Frequency converter
Type identifier
DA1
Rated voltage of employment
Ue 230 V AC, three-phase
240 V AC, 3-phasig
Output voltage (Ue
UTwo 230 V AC, three-phase
240 V AC, 3-phasig
Mains voltage (50/60Hz)
ULN V 200 (-10%) - 240 (+10%)
Rated current job
for an overload of 150 %
Ie Has Seven
Note
Rated current of employment at a switching frequency of 4 kHz and an ambient air temperature +40 °C
Note
Cycle of overload for 60 s every 600 s
Engine power corresponding
Note
For three-phase asynchronous motors tétrapolaires standards, internal cooling and surface area (1500 tr/min)-1at 50 Hz and 1800-1at 60 Hz
Note
Cycle of overload for 60 s every 600 s
Note
at 230 V, 50 Hz
150 % Overload
P kW 1.5
150 % Overload
Ie Has 6.3
Note
under 220 - 240 V, 60 Hz
150 % Overload
P HP Two
150 % Overload
Ie Has 6.8
Degree of protection
IP66/NEMA 4X
Interface/field bus (built-in)
OP-Bus (RS485)/Modbus RTU, CANopen®
Module coupling to field bus (option)
Ethernet IP
DeviceNet
PROFIBUS
PROFINET
Modbus-TCP
EtherCAT
BACnet/IP
SmartWire-DT
Equipment
Filter interference suppression
Braking unit
Display bright 7-segment
Organs of control on equipment
Size
FS2
Connection to SmartWire-DT
with module SmartWire-DT DX-NET-SWD2
Technical characteristics
General
Compliance with standards
General requirements : IEC/EN 61800-2
Requirements EMC : IEC/EN 61800-3
Safety requirements : IEC/EN 61800-5-1
Certifications
CE, cUL, UL, c-Tick, Ukr Sepro, EAC
Manufacturing quality
RoHS, ISO 9001
Climate resilience
ρw % < 95 %, average relative humidity (RH), non-condensing, non-corrosive (EN 50178)
Ambient temperature
Service (150 % surcharge).
ϑ °C -10 - +40
Storage
ϑ °C -40 - +60
Level of interference suppression
Class interference suppression (EMC)
C1, C2, C3 ; depends on the length of the connection cable to the motor, the connected load and the environment. If applicable, filters, surge suppressor, external (optional) are necessary.
Environment (EMC)
1st and 2nd environment
maximum length of motor cable
I m C1 ≤ 1 m
C2 ≤ 5 m
C3 ≤ 25 m
Mounting Position
Vertical
Altitude of installation
m 0 - 1000 m above sea level
above 1000 m : 1 % derating power 100 m
max. 4000 m
Degree of protection
IP66/NEMA 4X
Protection against direct contacts
BGV A3 (VBG4, protection against contact with the fingers and the back of the hand)
Main Circuit
Power
Rated voltage of employment
Ue 230 V AC, three-phase
240 V AC, 3-phasig
Mains voltage (50/60Hz)
ULN V 200 (-10%) - 240 (+10%)
Input current (overload 150 %)
ILN Has 7.3
Power
Networks of alternating current with the middle point connected to earth
Network frequency
fLN Hz 50/60
Frequency range
fLN Hz 48 - 62
Frequency power
every 30 seconds
Power part
Function
Frequency converters with intermediate circuit dc voltage and inverter IGBT
Overload current (overload 150 %)
IThe Has 10.5
Peak current at start-up max. (High Overload)
IH % Two hundred
A note about the peak current at start-up max.
for 4 seconds
Output voltage (Ue
UTwo 230 V AC, three-phase
240 V AC, 3-phasig
Output frequency
fTwo Hz 0 - 50/60 (max. 500)
Clock frequency
fPWM kHz Sixteen
adjustable 4 - 32 (audible)
Operation
Command U/f
Speed regulation with slip compensation
Control vector without sensor (SLV)
in option : control-vector with feedback (CLV)
Resolution of the frequency (setpoint)
Δf Hz 0.1
Rated current job
for an overload of 150 %
Ie Has Seven
Note
Rated current of employment at a switching frequency of 4 kHz and an ambient air temperature +40 °C
Power dissipated
Power dissipated under current assigned job
PV W 61.5
Performance
η % 95.9
Leakage current maximum at the ground (PE) without motor
IPE my 1.73
Equipment
Filter interference suppression
Braking unit
Display bright 7-segment
Organs of control on equipment
Safety function
STO (Safe Torque Off)
Size
FS2
Start engine
Note
For three-phase asynchronous motors tétrapolaires standards, internal cooling and surface area (1500 tr/min)-1at 50 Hz and 1800-1at 60 Hz
Note
Cycle of overload for 60 s every 600 s
Note
at 230 V, 50 Hz
150 % Overload
P kW 1.5
Note
under 220 - 240 V, 60 Hz
150 % Overload
P HP Two
Maximum permissible length of cable
I m shielded: 100
shielded, with inductance motor: 200
non-shielded: 150
non-armoured, with inductance motor: 300
Apparent power
Apparent power in rated service 230 V
S kVA 2.79
Apparent power in rated service 240 V
S kVA 2.91
Braking function
Braking torque Standard
max. 30 % MN
Braking torque Braking dc
100 %, adjustable
Braking torque with external braking resistor
max. 100% of the rated current of job Iewith external braking resistor
External braking resistor min.
Rmin Ω Fifty
Activation threshold for the braking transistor
UDC V 390 V DC
Part command
control voltage external
Uc V 24 V DC (max. 100 mA)
Voltage setpoint
Us V 10 V DC (max. 10 mA)
Analog inputs
2, configurable 0 - 10 V DC, 0/4 - 20 mA
Analog outputs
2, configurable 0 - 10 V, 0/4 - 20 mA
Entries all-or-nothing
3, configurable, 30 V DC max., 5 max. with analog inputs, non-parameterized
Outputs all-or-nothing
2, user configurable, 24 V DC
Relay outputs
2, software, with 1 normally open contact and 1 changeover contact, 6 A (250 V, AC-1) / 5 A (30 V, DC-1)
Interface/field bus (built-in)
OP-Bus (RS485)/Modbus RTU, CANopen®
Organs of control and protection suitable
Connection to the network
(IEC Type B, gG), 150 %
FAZ-B10/3
UL listed (Class CC or J)
Has Ten
150 % overload (CT/IHat 50 °C)
DX-LN3-010
Start engine
150 % overload (CT/IHat 50 °C)
DX-LM3-008
150 % overload (CT/IHat 50 °C)
DX-SIN3-010
10 % duty cycle (FM)
DX-BR050-0K4
20 % duty cycle (FM)
DX-BR050-0K8
Design verification according to IEC/EN 61439(display characteristics)(hide features)
Technical specifications for verification of design
Rated current job for indication of the power dissipated
In Has Seven
Power dissipated in the material, a function of the current
Pvid W 61.5
Certificate for IEC/EN 61439
10.2 Strength of materials and parts
10.2.2 Resistance to corrosion
The requirements of the product standard are met.
10.2.3.1 heat Resistance of the envelope
The requirements of the product standard are met.
10.2.3.2 Resistance of insulating Materials to Heat normal
The requirements of the product standard are met.
10.2.3.3 Resistance insulating Materials for outstanding Warmth
The requirements of the product standard are met.
10.2.4 Resistance to UV
The requirements of the product standard are met.
10.2.5 Elevation
Without object to the fact that the entire apparatus must be evaluated.
10.2.6 shock Test
Without object to the fact that the entire apparatus must be evaluated.
10.2.7 Inscriptions
The requirements of the product standard are met.
10.3 Degree of protection of the envelope
Without object to the fact that the entire apparatus must be evaluated.
10.4 isolation Distances and lines of flight
The requirements of the product standard are met.
10.5 Protection against electric shock
Without object to the fact that the entire apparatus must be evaluated.
10.6 Mounting hardware
Without object to the fact that the entire apparatus must be evaluated.
10.7 electrical Circuits and connections internal
Under the responsibility of the tableautier.
10.8 Connections for the conductors passed from the outside
Under the responsibility of the tableautier.
10.9 Properties of isolation
10.9.2 withstand Voltage at industrial frequency
Under the responsibility of the tableautier.
10.9.3 there Voltage shock
Under the responsibility of the tableautier.
10.9.4 Test envelope insulation
Under the responsibility of the tableautier.
10.10 Warm-up
The calculation of the warm-up is under the responsibility of the tableautier. Eaton provides the data of the dissipated power of the devices.
10.11 resistance to short-circuits
Under the responsibility of the tableautier. The specifications of the devices must be observed.
10.12 electromagnetic Compatibility
Under the responsibility of the tableautier. The specifications of the devices must be observed.
10.13 mechanical Operation
At the level of the device, the required conditions are met, to the extent the instructions of the installation manual (IT) are taken into account.
Technical data ETIM 5.0(View criteria)(Hide criteria)
Voltage of the network
V 200 - 240
Network frequency
50/60 Hz
Number of phases at the entrance
Three
Number of phases to the output
Three
Value max. the output frequency
Hz Five hundred
Nominal output voltage
V Two hundred thirty
Output current rating
Has Seven
Power output to the rated output voltage
kW 1.5
Value max. of output power with load, quadratic in the voltage nomi
kW 1.5
Value max. of the output power with linear load under the voltage-nominal
kW 1.5
With control element
Yes
Permitted use in industrial zones
Yes
uses allowed in the residential areas and tertiary
Yes
Supports protocoleTCP/IP
Not
Supports protocol PROFIBUS
Yes
Supports CAN protocol
Yes
Supports protocol INTERBUS
Not
Support protocol ASI
Not
Supports protocol EIB/KNX
Not
Supports MODBUS protocol
Yes
Supports protocol Data-Highway
Not
Supports protocol DeviceNet
Not
Supports protocol SUCONET
Not
Protocol LON
Not
Protocol for PROFINET IO
Yes
Protocol for PROFINET CBA
Not
Supports protocol SERCOS
Not
Protocol for Foundation Fieldbus
Not
Protocol for EtherNet/IP
Yes
Protocol for AS-Interface Safety at Work
Not
Protocol for DeviceNet Safety
Not
Protocol INTERBUS Safety
Not
Protocol for PROFIsafe
Not
Protocol for SafetyBUS p
Not
Supporting protocol for other bus systems
Not
Number of interfaces industrial Ethernet
Zero
Number of interface HW-PROFINET
Zero
Number of interfaces serial RS-232
Zero
Number of interfaces serial RS-422
Zero
Number of interfaces serial RS-485
One
Number of interfaces serial TTY
Zero
Number of USB interfaces
One
Number of interfaces parallel
Zero
Number of interfaces other
Zero
Optical Interface
Not
With connection to PC
Yes
Chopper (chopper) integrated braking
Yes
Operation in 4 quadrants possible
Not
Performance converters
Inverter U
Protection class (IP)
IP66
Height
mm Two hundred thirty one
Width
mm One hundred seven
Depth
mm One hundred eighty six
Relative tolerance of the frequency symmetrical to the network
% Five
Tolerance relative to the voltage symmetric to the network
% Ten
Approvals
Product Standards UL 508C; CSA-C22.2 No. 14; IEC/EN61800-3; IEC/EN61800-5; CE marking
UL File No. E172143
UL Category Control No. NMMS, NMMS7
CSA File No. UL report applies to both US and Canada
North America Certification UL listed, certified by UL for use in Canada
Specially designed for North America No.
Suitable for Branch circuits
Max. Voltage Rating 3~ 240 V AC IEC: TN-S UL/CSA: Y (Solidly Grounded Wey)
Degree of Protection IEC: IP66
Congestion
CAD data
More information on the products (links)

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.