DA1-324D3FB-A20N 169161 EATON ELECTRIC PowerXL Drive Series DA1 View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

DA1-324D3FB-A20N 169161 EATON ELECTRIC PowerXL Drive Series DA1

DA1-324D3FB-A20N

169161

EATON-MOELLER

PowerXL Drive - Series DA1

More details


Home > EATON - MOELLER

Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



Range of delivery
Range
Frequency converter
Type identifier
DA1
Rated voltage of employment
Ue 230 V AC, three-phase
240 V AC, 3-phasig
Output voltage (Ue
UTwo 230 V AC, three-phase
240 V AC, 3-phasig
Mains voltage (50/60Hz)
ULN V 200 (-10%) - 240 (+10%)
Rated current job
for an overload of 150 %
Ie Has 4.3
Note
Rated current of employment at a switching frequency of 4 kHz and an ambient air temperature of +50 °C
Note
Cycle of overload for 60 s every 600 s
Engine power corresponding
Note
For three-phase asynchronous motors tétrapolaires standards, internal cooling and surface area (1500 tr/min)-1at 50 Hz and 1800-1at 60 Hz
Note
Cycle of overload for 60 s every 600 s
Note
at 230 V, 50 Hz
150 % Overload
P kW 0.75
150 % Overload
Ie Has 3.2
Note
under 220 - 240 V, 60 Hz
150 % Overload
P HP One
150 % Overload
Ie Has 4.2
Degree of protection
IP20/NEMA 0
Interface/field bus (built-in)
OP-Bus (RS485)/Modbus RTU, CANopen®
Module coupling to field bus (option)
Ethernet IP
DeviceNet
PROFIBUS
PROFINET
Modbus-TCP
EtherCAT
BACnet/IP
SmartWire-DT
Equipment
Filter interference suppression
Braking unit
Display bright 7-segment
Size
FS2
Connection to SmartWire-DT
with module SmartWire-DT DX-NET-SWD1
Technical characteristics
General
Compliance with standards
General requirements : IEC/EN 61800-2
Requirements EMC : IEC/EN 61800-3
Safety requirements : IEC/EN 61800-5-1
Certifications
CE, cUL, UL, c-Tick, Ukr Sepro, EAC
Manufacturing quality
RoHS, ISO 9001
Climate resilience
ρw % < 95 %, average relative humidity (RH), non-condensing, non-corrosive (EN 50178)
Ambient temperature
Service (150 % surcharge).
ϑ °C -10 - +50
Storage
ϑ °C -40 - +60
Level of interference suppression
Class interference suppression (EMC)
C1, C2, C3 ; depends on the length of the connection cable to the motor, the connected load and the environment. If applicable, filters, surge suppressor, external (optional) are necessary.
Environment (EMC)
1st and 2nd environment
maximum length of motor cable
I m C1 ≤ 1 m
C2 ≤ 5 m
C3 ≤ 25 m
Mounting Position
Vertical
Altitude of installation
m 0 - 1000 m above sea level
above 1000 m : 1 % derating power 100 m
max. 4000 m
Degree of protection
IP20/NEMA 0
Protection against direct contacts
BGV A3 (VBG4, protection against contact with the fingers and the back of the hand)
Main Circuit
Power
Rated voltage of employment
Ue 230 V AC, three-phase
240 V AC, 3-phasig
Mains voltage (50/60Hz)
ULN V 200 (-10%) - 240 (+10%)
Input current (overload 150 %)
ILN Has 4.5
Power
Networks of alternating current with the middle point connected to earth
Network frequency
fLN Hz 50/60
Frequency range
fLN Hz 48 - 62
Frequency power
every 30 seconds
Power part
Function
Frequency converters with intermediate circuit dc voltage and inverter IGBT
Overload current (overload 150 %)
IThe Has 6.45
Peak current at start-up max. (High Overload)
IH % Two hundred
A note about the peak current at start-up max.
for 4 seconds
Output voltage (Ue
UTwo 230 V AC, three-phase
240 V AC, 3-phasig
Output frequency
fTwo Hz 0 - 50/60 (max. 500)
Clock frequency
fPWM kHz Sixteen
adjustable 4 - 32 (audible)
Operation
Command U/f
Speed regulation with slip compensation
Control vector without sensor (SLV)
in option : control-vector with feedback (CLV)
Resolution of the frequency (setpoint)
Δf Hz 0.1
Rated current job
for an overload of 150 %
Ie Has 4.3
Note
Rated current of employment at a switching frequency of 4 kHz and an ambient air temperature of +50 °C
Power dissipated
Power dissipated under current assigned job
PV W 39.75
Performance
η % 94.7
Leakage current maximum at the ground (PE) without motor
IPE my 1.73
Equipment
Filter interference suppression
Braking unit
Display bright 7-segment
Safety function
STO (Safe Torque Off)
Size
FS2
Start engine
Note
For three-phase asynchronous motors tétrapolaires standards, internal cooling and surface area (1500 tr/min)-1at 50 Hz and 1800-1at 60 Hz
Note
Cycle of overload for 60 s every 600 s
Note
at 230 V, 50 Hz
150 % Overload
P kW 0.75
Note
under 220 - 240 V, 60 Hz
150 % Overload
P HP One
Maximum permissible length of cable
I m shielded: 100
shielded, with inductance motor: 200
non-shielded: 150
non-armoured, with inductance motor: 300
Apparent power
Apparent power in rated service 230 V
S kVA 1.71
Apparent power in rated service 240 V
S kVA 1.79
Braking function
Braking torque Standard
max. 30 % MN
Braking torque Braking dc
100 %, adjustable
Braking torque with external braking resistor
max. 100% of the rated current of job Iewith external braking resistor
External braking resistor min.
Rmin Ω One hundred
Activation threshold for the braking transistor
UDC V 390 V DC
Part command
control voltage external
Uc V 24 V DC (max. 100 mA)
Voltage setpoint
Us V 10 V DC (max. 10 mA)
Analog inputs
2, configurable 0 - 10 V DC, 0/4 - 20 mA
Analog outputs
2, configurable 0 - 10 V, 0/4 - 20 mA
Entries all-or-nothing
3, configurable, 30 V DC max., 5 max. with analog inputs, non-parameterized
Outputs all-or-nothing
2, user configurable, 24 V DC
Relay outputs
2, software, with 1 normally open contact and 1 changeover contact, 6 A (250 V, AC-1) / 5 A (30 V, DC-1)
Interface/field bus (built-in)
OP-Bus (RS485)/Modbus RTU, CANopen®
Organs of control and protection suitable
Connection to the network
(IEC Type B, gG), 150 %
FAZ-B6/3
UL listed (Class CC or J)
Has Six
150 % overload (CT/IHat 50 °C)
DX-LN3-006
Start engine
150 % overload (CT/IHat 50 °C)
DX-LM3-005
150 % overload (CT/IHat 50 °C)
DX-SIN3-010
10 % duty cycle (FM)
DX-BR100-0K2
20 % duty cycle (FM)
DX-BR100-0K4
Design verification according to IEC/EN 61439(display characteristics)(hide features)
Technical specifications for verification of design
Rated current job for indication of the power dissipated
In Has 4.3
Power dissipated in the material, a function of the current
Pvid W 39.75
Certificate for IEC/EN 61439
10.2 Strength of materials and parts
10.2.2 Resistance to corrosion
The requirements of the product standard are met.
10.2.3.1 heat Resistance of the envelope
The requirements of the product standard are met.
10.2.3.2 Resistance of insulating Materials to Heat normal
The requirements of the product standard are met.
10.2.3.3 Resistance insulating Materials for outstanding Warmth
The requirements of the product standard are met.
10.2.4 Resistance to UV
The requirements of the product standard are met.
10.2.5 Elevation
Without object to the fact that the entire apparatus must be evaluated.
10.2.6 shock Test
Without object to the fact that the entire apparatus must be evaluated.
10.2.7 Inscriptions
The requirements of the product standard are met.
10.3 Degree of protection of the envelope
Without object to the fact that the entire apparatus must be evaluated.
10.4 isolation Distances and lines of flight
The requirements of the product standard are met.
10.5 Protection against electric shock
Without object to the fact that the entire apparatus must be evaluated.
10.6 Mounting hardware
Without object to the fact that the entire apparatus must be evaluated.
10.7 electrical Circuits and connections internal
Under the responsibility of the tableautier.
10.8 Connections for the conductors passed from the outside
Under the responsibility of the tableautier.
10.9 Properties of isolation
10.9.2 withstand Voltage at industrial frequency
Under the responsibility of the tableautier.
10.9.3 there Voltage shock
Under the responsibility of the tableautier.
10.9.4 Test envelope insulation
Under the responsibility of the tableautier.
10.10 Warm-up
The calculation of the warm-up is under the responsibility of the tableautier. Eaton provides the data of the dissipated power of the devices.
10.11 resistance to short-circuits
Under the responsibility of the tableautier. The specifications of the devices must be observed.
10.12 electromagnetic Compatibility
Under the responsibility of the tableautier. The specifications of the devices must be observed.
10.13 mechanical Operation
At the level of the device, the required conditions are met, to the extent the instructions of the installation manual (IT) are taken into account.
Technical data ETIM 6.0(View criteria)(Hide criteria)
voltage
V 200 - 240
frequency of the sector
50/60 Hz
number of input phases
Three
number of phases output
Three
output frequency max.
Hz Five hundred
output voltage: max.
V Two hundred thirty
output current nominal I2N
Has 4.3
output power max. support quadratic in output voltage rated
kW 0.75
output power max. linear load voltage output rated
kW 0.75
with control element
yes
use permitted in an industrial zone
yes
permitted use in residential and commercial area
yes
supported protocol for TCP/IP
not
supported protocol for PROFIBUS
yes
supported protocol for CAN
yes
supported protocol for INTERBUS
not
supported protocol for ASI
not
supported protocol for KNX
not
supported protocol for MODBUS
yes
supported protocol for Data-Highway
not
supported protocol for DeviceNet
not
supported protocol for SUCONET
not
supported protocol for LON
not
supported protocol for PROFINET IO
yes
supported protocol for PROFINET CBA
not
supported protocol for SERCOS
not
supported protocol for Foundation Fieldbus
not
supported protocol for EtherNet/IP
yes
supported protocol for AS-Interface Safety at Work
not
supported protocol for DeviceNet Safety
not
supported protocol for INTERBUS-Safety
not
supported protocol for PROFIsafe
not
supported protocol for SafetyBUS p
not
supported protocol for other bus systems
not
number of hardware interfaces Industrial Ethernet
Zero
number of hardware interfaces PROFINET
Zero
number of hardware interfaces RS-232 serial
Zero
number of hardware interfaces serial RS-422
Zero
number of hardware interfaces RS-485 serial
One
number of hardware interfaces serial TTY
Zero
number of hardware interfaces USB
One
number of hardware interfaces parallel
Zero
a number of other hardware interfaces
Zero
with optical interface
not
with connection to PC
yes
chopper integrated brake
yes
operation possible in four quadrants
not
type of converter
converter U
protection class (IP)
IP20
height
mm Two hundred thirty one
width
mm One hundred seven
depth
mm One hundred eighty six
tolerance relative frequency of the symmetrical network
% Five
relative tolerance of voltage of the symmetrical network
% Ten
Approvals
Product Standards UL 508C; CSA-C22.2 No. 14; IEC/EN61800-3; IEC/EN61800-5; CE marking
UL File No. E172143
UL Category Control No. NMMS, NMMS7
CSA File No. UL report applies to both US and Canada
North America Certification UL listed, certified by UL for use in Canada
Specially designed for North America No.
Suitable for Branch circuits
Max. Voltage Rating 3~ 240 V AC IEC: TN-S UL/CSA: Y (Solidly Grounded Wey)
Degree of Protection IEC: IP20
Congestion
CAD data
More information on the products (links)

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.