QM100/3N 1319916 EATON ELECTRIC Changeover switch, 2x4p, 100A, switch-disconnector View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

QM100/3N 1319916 EATON ELECTRIC Changeover switch, 2x4p, 100A, switch-disconnector

QM100/3N

1319916

EATON-MOELLER

Changeover switch, 2x4p, 100A, switch-disconnector

QM100/3N

Changeover switch, QM, 100 A, 2 x 3 pole + N (switched), without rotary handle, With drive shaft, 6 mm square

More details


DUMECO Switch-Disconnectors

* Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER

Total price: $255.97
Unit price: $255.97

Quantity Price
1+$255.97
2+$232.71
3+$230.27
*This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



Changeover switch, QM, 100 A, 2 x 3 pole + N (switched), without rotary handle, With drive shaft, 6 mm square
Switch-disconnector QM100/3N, changeover switch, 2x4 pole (3P + switched N), free air thermal current Ithe 100 A, with shaft 6mm square

General specifications
Product name
Eaton QM Changeover switch
Part no.
QM100/3N
EAN
8711426233317
Product Length/Depth
19.5 millimetre
Product height
14.2 millimetre
Product width
10.7 millimetre
Product weight
1.1 kilogram
Certifications
VDE 0660
IEC/EN 60947
CE
RoHS
IEC/EN 60947-3
IEC/EN 60204
Product Tradename
QM
Product Type
Changeover switch
Product Sub Type
None
Features & Functions
Fitted with:
Drive shaft
Functions
Optional Stop Function
Number of poles
Four-pole
General information
Accessories
Auxiliary contact fitted by user.
Actuator type
Other
Degree of protection
NEMA Other
Degree of protection (front side)
IP20
Mounting method
Rear mounting
Top-hat rail mounting
Mounting position
As required
Overvoltage category
III
Pollution degree
3
Product Category
Changeover switches
Rated impulse withstand voltage (Uimp)
6000 V
Safety parameter (EN ISO 13849-1)
B10d values as per EN ISO 13849-1, table C.1
Climatic environmental conditions
Ambient operating temperature - min
-25 °C
Ambient operating temperature - max
55 °C
Ambient storage temperature - min
-30 °C
Ambient storage temperature - max
80 °C
Terminal capacities
Terminal capacity
1 x (10 - 50) mm², solid
1 x (10 - 35) mm², flexible
Stripping length (main cable)
14 mm
Tightening torque
3 Nm, Screw terminals
Electrical rating
Rated conditional short-circuit current (Iq)
15 kA
Rated insulation voltage (Ui)
690 V
Rated operational power at AC-23A, 400 V, 50 Hz
37 kW
Rated operational power at AC-3, 380/400 V, 50 Hz
30 kW
Rated operational voltage (Ue) at AC - max
690 V
Rated uninterrupted current (Iu)
100 A
Uninterrupted current
Rated uninterrupted current Iu is specified for max. cross-section.
Contacts
Number of auxiliary contacts (normally closed contacts)
0
Number of auxiliary contacts (normally open contacts)
0
Design verification
Equipment heat dissipation, current-dependent Pvid
0 W
Heat dissipation capacity Pdiss
0 W
Heat dissipation per pole, current-dependent Pvid
8 W
Rated operational current for specified heat dissipation (In)
100 A
Static heat dissipation, non-current-dependent Pvs
0 W
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.