DT01 CARLO GAVAZZI Selected parameters MODULE TYPE Accessory HOUSING DIN-rail POWER SUPPLY none I/O TYPE No.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

DT01 CARLO GAVAZZI Selected parameters MODULE TYPE Accessory HOUSING DIN-rail POWER SUPPLY none I/O TYPE No..

DT01

CARLO GAVAZZI

Available

Ship on today

Selected parameters MODULE TYPE Accessory HOUSING DIN-rail POWER SUPPLY none I/O TYPE None NUMBER OF I/O 0 Others MODULE TYPE Termination unit HOUSING H1 (W18) I/O TYPE None POWER SUPPLY none MAIN CHARACTERISTICS Dupline termination unit to avoid cable reflections

More details


Converters

Fieldbuses

Field Installation Bus and Safety Bus, Car Park “Guidance” System, Elevator Controls and Irrigation Systems

* Brand new product in its original packaging covered by the warranties and certifications provided by CARLO GAVAZZI

Quantity Price
1+$61.47
5+$55.46
10+$53.77
14+$53.09
19+$52.58
*This price is per unit and is the net value (not including taxes if applicable).

Related products

More info



Cable Termination Unit
Type DT 01
Duline®
FieldbusInstallationbus
• Removes distortion caused by reflections
• H1-housing
• For mounting on DIN-rail (EN 50022)
• No power supply needed
Product Description
Ordering Key
DT 01
Dupline®terminationunitfor removing distortion caused by
Type Selection
reflections from thecable ends.
Type: Dupline®
Type no.
General Specifications
Ordering no.
Cable termination unit
DT 01
No code module required
Supply Specifications
Rated operational currentTyp. 220 µA
Power dissipation £ 10 mW
Environment
Degree of protection IP 20
Pollution degree3 (IEC 60664)
Operating temperature-20° to +50°C (-4° to +122°F) Storage temperature -50° to +85°C (-58° to +185°F)
Humidity (non-condensing)0 to 80%
Mechanical resistance
Shock15 G (11 ms) Vibration 2 G (6 to 55 Hz)
Dimensions
Material
(see "Technical Information") H1-Housing
Weight45 g
Modeof Operation
When a generator connected to a non-terminated cable emits a square-wave signal, the cable ends will always cause reflections.Depending ondistanceandfrequency, the signal can be distorted to a degree where the informa- tion becomes unreliable. However, these reflections can easily be removed by mounting the correct termina-
tion at the cable end. In the case ofDupline®thecritical distance between the genera- tor and the far cable end is 2 km and above. Consequently, if as a rule of thumb a DT 01 termination unit is mounted at the cable end when the dis- tance to the channel genera- tor exceeds 1.2 km, reflec- tions are avoided.
Note 1:
In case ofbranches onthe cableit is only necessary to mount a second DT 01 if the distanceto the nearest DT 01 exceeds 1.2 km. In all other cases a second DT 01 should notbe mountedsince itin- creases thecapacityofthe cableandtherebyreduces the transmission distance.
Note 2:
The DT 01istheonlyunit which can remove reflections and consequently cannot be replaced by other Dupline® modules.
Specifications are subject to change without notice (28.04.03)1
Dupline®is a registered trademark. A product of the CARLO GAVAZZI Group

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

Últimas Opiniones de Nuestros Clientes

Todas las valoraciones que recibimos de los artículos que ofrecemos son reales y están verificadas. Un pequeño gesto, pero de mucho valor. Por eso, te agradecemos ese minuto que inviertes en dejarnos tu opinión y calificación sobre los productos, porque nos ayuda a seguir mejorando y a ofrecerte un servicio de todavía mayor calidad.