1SDA073386R1 ABB E6.2X/F 6300 EKIP TOUCH LSIG 4P W MP View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

1SDA073386R1 ABB E6.2X/F 6300 EKIP TOUCH LSIG 4P W MP

1SDA073386R1

ABB

E6.2X/F 6300 EKIP TOUCH LSIG 4P W MP

E6.2X/f 6300 Ekip Touch LSIG 4P W MP

More details


Low-voltage industrial components > Power circuit-breaker for trafo/generator/installation protection

Rack "Megamax-Emax"

Brand new product in its original packaging covered by the warranties and certifications provided by ABB

Total: $81,160.19
Unit price: $81,160.19
This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



ABB EcoSolutions
ABB EcoSolutionsYes
ABB Site Meeting Group Waste To Landfill TargetUL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions9AKK108468A2364
Environmental Product Declaration - EPD9AKK108468A1905
9AKK108468A1913
Extended Product LifetimeLifetime Extension Services are Offered
Recyclability Rate of the Product acc. to EN45555Design for Closing Resource Loops - Standard EN45555 - 77 %
Material Compliance
REACH Declaration9AKK108466A1425
RoHS Declaration9AKK108466A1424
RoHS InformationFollowing EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)9AKK108467A5658
Toxic Substances Control Act - TSCA9AKK108467A8326
SCIP12ef09cb-f07c-497f-881f-3fc0aff3fdfa Italy
Simplified SCIPc4a3c1a7-c551-4109-b483-f8e1617fc293 Belgium
a53fb59e-0281-45cb-b6e7-36e037b4639b Hungary
61d21342-4422-4905-a394-056c38af69a0 Germany
8f9d0e98-8fa7-4f92-b8bc-00d5d0dc6919 France
c1fb1c59-4d7c-42c2-a318-9140b8d3eb20 Spain
44e8c1f9-c069-44e0-9a3a-d533326534ca Sweden
ec4f9ad3-2795-4a29-a56e-e7d80427e786 Germany
e0ddcbd7-3fa6-4d69-ac4e-ec235c19ae88 Germany
f31e6edb-8d62-4c25-9b18-0720d3fb27ee Poland
0f38c352-8736-4b8b-bf7d-8f2d84e4439e Germany
9a8579a5-0419-4c61-9b8d-2f35cb30c38b Belgium
53217f55-459e-4453-b279-2c9912e64f20 Denmark
4a25e0df-6204-4f84-a547-b9b72e067111 Finland
392491de-2099-49af-a28d-aef5cc12417c Norway
75c0d5a8-110b-41d6-b1fc-01c545229a8a Croatia
a513c474-903d-4255-b09b-63dbc74f29b8 Germany
d38115ad-2593-4666-9d3b-3e90fceeadfb Poland
9c4c284d-9b80-49af-80c4-844de0976744 Czech Republic
62428590-807a-461c-843a-5483d19a9aa7 Netherlands
b3cc6d1c-9436-4413-9029-a0e88407faeb Hungary
b438ee97-71e3-4673-8437-b0b2f816eae2 Portugal
e20a83cd-8759-4cd0-92f6-890b295b078d Estonia
533bdddf-9dfb-4941-a33d-682ebea63f29 Greece
4abe48f8-4d98-4040-9b57-b048a8b47a31 Sweden
cfb5d7a6-63b8-405c-a824-2552e60228ed Bulgaria
f9259380-23f7-497f-9b9a-c4d71ad4bd75 France
4ff8f2a4-fa08-49ed-a796-109515567f7a Poland
Environmental
Environmental Information9AKK108467A6707
Ordering
EAN8015644772369
Minimum Order Quantity1 piece
Customs Tariff Number85362090
Dimensions
Product Net Width1069 mm
Product Net Height425 mm
Product Net Depth / Length383 mm
Product Net Weight148 kg
Container Information
Package Level 1 Unitsbox 1 piece
Package Level 1 Width515 mm
Package Level 1 Height610 mm
Package Level 1 Depth / Length1257 mm
Package Level 1 Gross Weight159 kg
Package Level 1 EAN8015644772369
Additional Information
Product Main TypeSACE Emax 2
Product NameAir Circuit Breaker
Product TypeAir Circuit Breaker
VersionW
Technical
Connecting Capacity6000 mm²
Current TypeAC
Electrical DurabilityUe =< 440 V 2000 cycle
Ue = 500 ... 690 V 2000 cycle
10 cycles per hour
Mechanical Durability12000 cycle
60 cycles per hour
Neutral Pole Current ([%Iu])100 %
Number of Poles4 / f
Power Loss1550 W
Rated Current (In)6300 A
Rated Impulse Withstand Voltage (Uimp)acc. to IEC 60947-2 12 kV
Rated Insulation Voltage (Ui)AC 1000 V
Rated Operational Voltage690 V AC
Rated Service Short-Circuit Breaking Capacity (Ics)(220 V AC) 100 kA
(230 V AC) 100 kA
(380 V AC) 100 kA
(400 V AC) 100 kA
(415 V AC) 100 kA
(440 V AC) 100 kA
(500 V AC) 100 kA
(660 V AC) 100 kA
(690 V AC) 100 kA
Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics)100 %
Rated Short-time Withstand Current Low Voltage (Icw)for 1 s 120 kA
for 3 s 100 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)(440 V AC) 200 kA
Rated Uninterrupted Current (Iu)6300 A
Rated Voltage (Ur)690 V
Recommended Screw DriverM12
ReleaseEkip Touch LSIG
Release TypeEL
Short-Circuit Performance LevelX
StandardsIEC
Sub-typeE6.2
Suitable for IT NetworksYes, 690V
Certificates and Declarations
Data Sheet, Technical Information1SDC200023D0209
Declaration of Conformity - CE9AKK106713A5544
EU Data Act Compliance Declaration1SDH002560A1001
Instructions and Manuals1SDH001000R0002
Instructions and Manuals (Part 2)1SDH001316R1002
External Classifications and Standards
ETIM 9EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 10EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification CodeQ
WEEE Category4. Large Equipment (Any External Dimension More Than 50 cm)
eClassV11.1 : 27370409

Datasheet - PDF

Title: Size: Type:
PDF CATALOG EMAX 2 EN.pdf 207 Mbytes

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.