Product successfully added to your shopping cart
1SDA071798R1
ABB
1
E4.2H 3200 Ekip Hi-Touch LSI 4p F HR
Low-voltage industrial components > Power circuit-breaker for trafo/generator/installation protection
Rack "Megamax-Emax" > E4.2
Brand new product in its original packaging covered by the warranties and certifications provided by ABB
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2363 |
| Environmental Product Declaration - EPD | 9AKK108468A1904 |
| 9AKK108468A1910 | |
| Extended Product Lifetime | Lifetime Extension Services are Offered |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 79.3 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 9d176fac-e423-4c28-be3f-ecdce558cc7d Italy |
| Simplified SCIP | 29e835be-2467-404b-80b6-a316a5d8fe39 Germany |
| 2fb1705c-ae7f-40d8-bba9-5d9c73685f1c Czech Republic | |
| 90efdeb2-b283-4983-9e03-38d13d88e73f Hungary | |
| e92baac9-a576-434b-976b-6d327b3f5848 Norway | |
| 141df488-3458-49b1-baeb-61b6bedb3bcf Poland | |
| a871fbc2-9b5b-46a3-90c9-2ff87ed23518 Croatia | |
| 7aeba3ba-99e2-407a-b8e2-233261148760 France | |
| 687ded11-f7e4-4955-97b8-8ee98b36dd1b Germany | |
| a848bb63-dca6-4184-b027-39f03a3c9a4e Denmark | |
| b275fb27-e01a-4e1b-8c84-891ed735034d Germany | |
| 0c399ff1-cf11-48c5-b80a-1eeffeca1805 Netherlands | |
| a1c9b47c-e98a-42d3-b2b6-cd39968bd176 Greece | |
| 0eb2a150-e92a-4360-ab02-a24e6aee0a47 Estonia | |
| 789d1956-e40f-4cc9-91fa-0b2854fc8de2 France | |
| d2bde273-90ec-40d7-9436-c03b86ea1a2e Finland | |
| 25b6adb0-8705-4db2-94dc-40d7e4175929 Belgium | |
| 4b806aef-e9c6-4807-8b7f-aa8b7c3357d2 Sweden | |
| 5806c60e-b35c-431d-b979-fb55e7a91662 Germany | |
| e39437fa-171f-4c4d-a04f-95c3bc7f7389 Germany | |
| 66afbb2e-54a1-4fa3-9142-e3743982684d Portugal | |
| d468ca6d-b1e4-4d75-a7a2-8455609222e8 Bulgaria | |
| 5cf882a8-ebd6-44e1-85c3-521c77f7ab87 Sweden | |
| 3f37c7f2-59bf-464e-a343-b22e7f8e1e67 Poland | |
| 082e5152-4d8d-4c56-85ce-0b672d0fc8cc Poland | |
| d8c8c7ce-4135-496d-a2b3-4ae5d0901b1b Belgium | |
| 32dc418a-bb68-4487-83a0-f74d76947956 Spain | |
| 01a1bf07-5fd9-4d7b-8f16-b039db5822f5 Hungary | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | ZCHVENBJ200A000000XX |
| EAN | 8015644756482 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 510 mm |
| Product Net Height | 371 mm |
| Product Net Depth / Length | 270 mm |
| Product Net Weight | 70 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 515 mm |
| Package Level 1 Height | 610 mm |
| Package Level 1 Depth / Length | 785 mm |
| Package Level 1 Gross Weight | 77 kg |
| Package Level 1 EAN | 8015644756482 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | F |
| CAD Dimensional Drawing | 1SDH001252R0197 |
| Technical | |
| Connecting Capacity | 3000 mm² |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 7000 cycle |
| Ue = 500 ... 690 V 7000 cycle | |
| 20 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 60 cycles per hour | |
| Neutral Pole Current ([%Iu]) | 100 % |
| Number of Poles | 4P |
| Power Loss | 425 W |
| Rated Current (In) | 3200 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 100 kA |
| (230 V AC) 100 kA | |
| (380 V AC) 100 kA | |
| (400 V AC) 100 kA | |
| (415 V AC) 100 kA | |
| (440 V AC) 100 kA | |
| (500 V AC) 85 kA | |
| (660 V AC) 85 kA | |
| (690 V AC) 85 kA | |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 100 % |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 85 kA |
| for 3 s 66 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 100 kA |
| (415 V AC) 100 kA | |
| (440 V AC) 100 kA | |
| (500 V AC) 85 kA | |
| (525 V AC) 85 kA | |
| (690 V AC) 85 kA | |
| Rated Uninterrupted Current (Iu) | 3200 A |
| Rated Voltage (Ur) | 690 V |
| Recommended Screw Driver | M12 |
| Release | Ekip Hi-Touch LSI |
| Release Type | EL |
| Short-Circuit Performance Level | H |
| Standards | IEC |
| Sub-type | E4.2 |
| Suitable for IT Networks | Yes, 690V |
| Terminal Connection Type | Rear flat Horizontal |
| Terminal Type | Bolt |
| Tightening Torque | 70 N·m |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| CSA Certificate | No certification needed |
| CSA Certificate (Intrinsic Safe) | No certification needed |
| Data Sheet, Technical Information | 1SDC200023D0209 |
| Declaration of Conformity - CE | 9AKK106713A5545 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Mechanical Drawings | 1SDH001001R0100 |
| Wiring Diagram | 1SDM000091R0001 |
| Instructions and Manuals | 1SDH001000R0002 |
| Instructions and Manuals (Part 2) | 1SDH001316R1002 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| IDEA Granular Category Code (IGCC) | 4926 >> Air circuit breakers |
| Object Classification Code | Q |
| UNSPSC | 39121615 |
| WEEE Category | 4. Large Equipment (Any External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOG EMAX 2 EN.pdf | 207 Mbytes |
|
| E4.2H 3200 Ekip Hi-Touch LSI 4p F HR - ABB - E4.2H3200 - 1SDA071798R1 | 91 Kbytes |
![]() |
| E4.2H3200 1SDA071798R1 ABB E4.2H 3200 Ekip Hi-Touch LSI 4p F HR | 80 Kbytes |
![]() |
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.