ANUNCIAR
1SDA071572R1 ABB E2.2H 1000 Ekip Dip LSI 4p F HR View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

1SDA071572R1 ABB E2.2H 1000 Ekip Dip LSI 4p F HR

1SDA071572R1

ABB

E2.2H 1000 Ekip Dip LSI 4p F HR

More details


Low-voltage industrial components > Power circuit-breaker for trafo/generator/installation protection

Rack "Megamax-Emax" > E2.2

Brand new product in its original packaging covered by the warranties and certifications provided by ABB

Total: $9,490.45
Unit price: $9,490.45
This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



ABB EcoSolutions
ABB EcoSolutionsYes
ABB Site Meeting Group Waste To Landfill TargetUL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions9AKK108468A2361
Environmental Product Declaration - EPD9AKK108468A1902
9AKK108468A1909
Extended Product LifetimeLifetime Extension Services are Offered
Recyclability Rate of the Product acc. to EN45555Design for Closing Resource Loops - Standard EN45555 - 79.1 %
Material Compliance
REACH Declaration9AKK108466A1425
RoHS Declaration9AKK108466A1424
RoHS InformationFollowing EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)9AKK108467A5658
Toxic Substances Control Act - TSCA9AKK108467A8326
SCIPd92cf5d6-c995-4f0f-b41e-9ceabf5e81d3 Italy
Simplified SCIP6dfa8af0-cc77-4e11-8c74-51fb0c36bbd9 Germany
07539f99-1ccf-4de0-b437-bfec109ea93b Czech Republic
c1685f36-08ea-4c5c-8ca4-40df48a84b42 Poland
22f9c8dd-f806-4b03-a60f-838880ddbb1e Poland
e7ed62bc-c957-4ac2-bb5d-50d31cff4740 Portugal
4e5ef2c4-e7a0-4f92-a180-35ae554065b4 Sweden
c4a910b4-29d5-453f-83c0-10c44eb1e02e Belgium
70eaa15b-20a1-40db-8db8-84a77182c6c8 Spain
3063c260-f23e-4cd5-aabf-401415ba912b France
5ada7cd9-484e-4239-aa7c-987fbd4f5452 Belgium
957a97ba-c828-4e9d-ac4d-fe440fd0059c Sweden
6f5d4a26-c838-44f2-b1ec-e72b4778720d Finland
96db8fb1-4550-4a30-8aef-14c74b8d0ace Netherlands
9bcf8916-7c4f-4059-b141-49851d940cbb Estonia
8a3b0020-0bc7-47eb-8a9f-f4c79f0b640e France
86365bf3-e7bc-498a-ac90-76e26c06c31c Greece
e8d82739-675e-46c7-9197-1a58f881a8a8 Bulgaria
f2db9202-e471-40c7-8d20-f5e56f6be1da Germany
b7e429fe-11e5-45f9-8ac9-88cb1b7c7730 Croatia
5d54b629-ad25-430a-a6dc-1c41f6b679b1 Germany
9e22a7b6-a175-4b45-ac97-6e0d2262ea89 Germany
3b2498bb-fa8d-4544-b9f6-d64b608387b5 Denmark
98c0c522-7eb1-4947-8ea4-3bd243260da1 Germany
583da5f2-d19c-4854-939b-31999349e9dc Hungary
88528e4c-eb3d-40d0-bf37-ac0abcaae75e Poland
4c37efa6-cfd0-439a-a36b-07fd0fd76243 Norway
570285eb-4986-419c-814d-e0abc113654e Hungary
Environmental
Environmental Information9AKK108467A6707
Ordering
Order Code US and CanadaZBHQEGBB000A000000XX
EAN8015644754228
Minimum Order Quantity1 piece
Customs Tariff Number85362090
Dimensions
Product Net Width366 mm
Product Net Height371 mm
Product Net Depth / Length270 mm
Product Net Weight53 kg
Container Information
Package Level 1 Unitsbox 1 piece
Package Level 1 Width515 mm
Package Level 1 Height610 mm
Package Level 1 Depth / Length615 mm
Package Level 1 Gross Weight58 kg
Package Level 1 EAN8015644754228
Additional Information
Product Main TypeSACE Emax 2
Product NameAir Circuit Breaker
Product TypeAir Circuit Breaker
VersionF
CAD Dimensional Drawing1SDH001252R0123
Technical
Connecting Capacity600 mm²
Current TypeAC
Electrical DurabilityUe =< 440 V 15000 cycle
Ue = 500 ... 690 V 15000 cycle
30 cycles per hour
Mechanical Durability25000 cycle
60 cycles per hour
Neutral Pole Current ([%Iu])100 %
Number of Poles4P
Power Loss53 W
Rated Current (In)1000 A
Rated Impulse Withstand Voltage (Uimp)acc. to IEC 60947-2 12 kV
Rated Insulation Voltage (Ui)AC 1000 V
Rated Operational Voltage690 V AC
Rated Service Short-Circuit Breaking Capacity (Ics)(220 V AC) 100 kA
(230 V AC) 100 kA
(380 V AC) 100 kA
(400 V AC) 100 kA
(415 V AC) 100 kA
(440 V AC) 100 kA
(500 V AC) 85 kA
(660 V AC) 85 kA
(690 V AC) 85 kA
Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics)100 %
Rated Short-time Withstand Current Low Voltage (Icw)for 1 s 85 kA
for 3 s 66 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)(400 V AC) 100 kA
(415 V AC) 100 kA
(440 V AC) 100 kA
(500 V AC) 85 kA
(525 V AC) 85 kA
(690 V AC) 85 kA
Rated Uninterrupted Current (Iu)1000 A
Rated Voltage (Ur)690 V
Recommended Screw DriverM12
ReleaseEkip Dip LSI
Release TypeEL
Short-Circuit Performance LevelH
StandardsIEC
Sub-typeE2.2
Suitable for IT NetworksYes, 690V
Terminal Connection TypeRear flat Horizontal
Terminal TypeBolt
Tightening Torque70 N·m
Certificates and Declarations
ATEX CertificateNo certification needed
CSA CertificateNo certification needed
CSA Certificate (Intrinsic Safe)No certification needed
Data Sheet, Technical Information1SDC200023D0209
Declaration of Conformity - CE9AKK106713A5902
EU Data Act Compliance Declaration1SDH002560A1001
UL CertificateNo certification needed
VDE CertificateNo certification needed
Mechanical Drawings1SDH001000R0100 
Wiring Diagram1SDM000091R0001
Instructions and Manuals1SDH001000R0002
External Classifications and Standards
ETIM 9EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 10EC000228 - Power circuit-breaker for trafo/generator/installation protection
IDEA Granular Category Code (IGCC)4926 >> Air circuit breakers
Object Classification CodeQ
UNSPSC39121615
WEEE Category5. Small Equipment (No External Dimension More Than 50 cm)
eClassV11.1 : 27370409

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.