ANUNCIAR
1SDA071351R1 ABB E1.2N 630 Ekip Dip LI 4p F F View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

1SDA071351R1 ABB E1.2N 630 Ekip Dip LI 4p F F

1SDA071351R1

ABB

E1.2N 630 Ekip Dip LI 4p F F

More details


Low-voltage industrial components > Power circuit-breaker for trafo/generator/installation protection

Rack "Megamax-Emax" > E1.2

Brand new product in its original packaging covered by the warranties and certifications provided by ABB

Total: $6,093.66
Unit price: $6,093.66
This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



ABB EcoSolutions
ABB EcoSolutionsYes
ABB Site Meeting Group Waste To Landfill TargetUL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions9AKK108468A2360
Environmental Product Declaration - EPD9AKK108468A1900
9AKK108468A3028
Extended Product LifetimeLifetime Extension Services are Offered
Recyclability Rate of the Product acc. to EN45555Design for Closing Resource Loops - Standard EN45555 - 76.4 %
Material Compliance
REACH Declaration9AKK108466A1425
RoHS Declaration9AKK108466A1424
RoHS InformationFollowing EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)9AKK108467A5658
Toxic Substances Control Act - TSCA9AKK108467A8326
SCIPe58f8ea5-64f9-48da-8dbb-f7adebb805dd India
Simplified SCIP7dbd687d-cee2-4486-8cfe-8407ba092fc6 Germany
09232a31-03ec-4a60-b8f1-e60815820511 Sweden
c2926879-6903-4abc-9a8f-936175231ce2 Portugal
0e8abb12-d8b7-46ed-b1d7-77fc8f8f69e7 Czech Republic
0b544de2-8f63-4587-80b9-ea307feb8cdd Hungary
ce6e02f9-9552-471f-a111-5964162b1fb5 Poland
7e71bd4a-9fed-48b7-a57a-f4ebae53cbb0 Netherlands
46226e19-422a-4654-9658-c1b38ba79fa3 Finland
059aeffc-1ad0-4672-bd62-32a9a3e249e3 Hungary
1d1a0c33-7c8a-4dc0-91de-0746c8e30fd6 Spain
d1108b16-7055-441f-ae5e-0bac50f4ec69 Belgium
1d686f6d-8d3e-43a6-97bb-f8102a813b01 Estonia
e6c31c47-423a-4abd-96e1-e00a7ebce603 Croatia
8a446412-6054-473c-8a6b-e703667db310 Germany
5aa5e42b-bea1-4d26-ba18-82b609ce656b Germany
782c4d8d-4518-44b3-aef2-e14f843f8efb Denmark
1b001162-0e2d-481b-9125-7f53e6e004da Belgium
ffe42a8e-739c-485b-9c24-c73b961749b9 Norway
666ca32d-fc03-400b-b452-ddb0170631b1 Poland
8c86a8a2-d93a-4281-be03-80bba61caeee Germany
f06ce1a8-b9b3-4446-b280-69745ff36f3e France
23cccfdc-90a6-4e53-af7b-61a3af52a52d Poland
a3a6bd5d-2891-4ce4-b6b8-88242960a953 France
3b9ab8c5-96d4-4173-a13c-8d8a46b9d7c7 Sweden
2c83829e-5c2e-4a94-999a-77291b0f1120 Bulgaria
18bfb485-2a59-428c-b14d-f301af89528c Greece
8ca4499a-a76f-4d50-aaa2-f9ca4b441b94 Germany
Environmental
Environmental Information9AKK108467A6707
Ordering
Order Code US and CanadaZANNEEBA000A000000XX
EAN8015644752019
Minimum Order Quantity1 piece
Customs Tariff Number85362090
Dimensions
Product Net Width280 mm
Product Net Height296 mm
Product Net Depth / Length183 mm
Product Net Weight16 kg
Container Information
Package Level 1 Unitsbox 1 piece
Package Level 1 Width350 mm
Package Level 1 Height350 mm
Package Level 1 Depth / Length330 mm
Package Level 1 Gross Weight18 kg
Package Level 1 EAN8015644752019
Additional Information
Product Main TypeSACE Emax 2
Product NameAir Circuit Breaker
Product TypeAir Circuit Breaker
VersionF
CAD Dimensional Drawing1SDH001252R0042
Technical
Connecting Capacity400 mm²
Current TypeAC
Electrical DurabilityUe =< 440 V 8000 cycle
Ue = 500 ... 690 V 8000 cycle
30 cycles per hour
Mechanical Durability20000 cycle
60 cycles per hour
Neutral Pole Current ([%Iu])100 %
Number of Poles4P
Power Loss31 W
Rated Current (In)630 A
Rated Impulse Withstand Voltage (Uimp)acc. to IEC 60947-2 12 kV
Rated Insulation Voltage (Ui)AC 1000 V
Rated Operational Voltage690 V AC
Rated Service Short-Circuit Breaking Capacity (Ics)(220 V AC) 50 kA
(230 V AC) 50 kA
(380 V AC) 50 kA
(400 V AC) 50 kA
(415 V AC) 50 kA
(440 V AC) 50 kA
(500 V AC) 50 kA
(660 V AC) 50 kA
(690 V AC) 50 kA
Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics)100 %
Rated Short-time Withstand Current Low Voltage (Icw)for 1 s 50 kA
for 3 s 30 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)(400 V AC) 66 kA
(415 V AC) 66 kA
(440 V AC) 66 kA
(500 V AC) 50 kA
(525 V AC) 50 kA
(690 V AC) 50 kA
Rated Uninterrupted Current (Iu)630 A
Rated Voltage (Ur)690 V
Recommended Screw DriverM12
ReleaseEkip Dip LI
Release TypeEL
Short-Circuit Performance LevelN
StandardsIEC
Sub-typeE1.2
Suitable for IT NetworksYes, 690V
Terminal Connection TypeFront
Terminal TypeBolt
Tightening Torque45 N·m
Certificates and Declarations
ATEX CertificateNo certification needed
CSA CertificateNo certification needed
CSA Certificate (Intrinsic Safe)No certification needed
Data Sheet, Technical Information1SDC200023D0209
Declaration of Conformity - CE9AKK106713A5546
EU Data Act Compliance Declaration1SDH002560A1001
UL CertificateNo certification needed
VDE CertificateNo certification needed
Mechanical Drawings1SDH000999R0101
Wiring Diagram1SDM000091R0001
Instructions and Manuals1SDH000999R0002
External Classifications and Standards
ETIM 9EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 10EC000228 - Power circuit-breaker for trafo/generator/installation protection
IDEA Granular Category Code (IGCC)4926 >> Air circuit breakers
Object Classification CodeQ
UNSPSC39121615
WEEE Category5. Small Equipment (No External Dimension More Than 50 cm)
eClassV11.1 : 27370409

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.