ANUNCIAR
1SDA071435R1 ABB E1.2N 1000 Ekip Touch LSI 4p F F View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

1SDA071435R1 ABB E1.2N 1000 Ekip Touch LSI 4p F F

1SDA071435R1

ABB

E1.2N 1000 Ekip Touch LSI 4p F F

More details


Low-voltage industrial components > Power circuit-breaker for trafo/generator/installation protection

Rack "Megamax-Emax" > E1.2

Brand new product in its original packaging covered by the warranties and certifications provided by ABB

Total: $6,689.38
Unit price: $6,689.38
This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



ABB EcoSolutions
ABB EcoSolutionsYes
ABB Site Meeting Group Waste To Landfill TargetUL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions9AKK108468A2360
Environmental Product Declaration - EPD9AKK108468A1900
9AKK108468A3028
Extended Product LifetimeLifetime Extension Services are Offered
Recyclability Rate of the Product acc. to EN45555Design for Closing Resource Loops - Standard EN45555 - 76.4 %
Material Compliance
REACH Declaration9AKK108466A1425
RoHS Declaration9AKK108466A1424
RoHS InformationFollowing EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)9AKK108467A5658
Toxic Substances Control Act - TSCA9AKK108467A8326
SCIP0953df47-96b2-4e46-afc9-07e6e22df654 Italy
Simplified SCIPb7287978-2ebf-4947-8b3d-3efa7a18cd65 Germany
9d5a60a4-f4be-491f-ac29-e3c61b130e46 Germany
bb6a2c30-0d88-4d35-a405-a67051d283f1 France
656c4cc1-0e10-4786-b4fb-b88cad5d1927 Germany
8b9733b3-ca98-459f-a031-8db6ee467c09 Denmark
e9960311-5f19-47c2-a846-efece147e4fc Finland
76b6ea01-af93-49ad-80d2-4ee83dfb0164 Belgium
769385ab-9764-4f4a-8c48-8a2813535950 Norway
59bf27df-689a-477e-b152-248938a859ab Poland
4dbe6e33-d936-48ab-a078-cdf86ff5ac9e Germany
cf7d5033-be7e-4325-a61f-4dc874bdb269 Hungary
6f278f5a-0ccc-4fb2-a967-5fa5f98c20c7 Netherlands
ee94eb0c-bb29-48ee-9345-806574f78fcd Estonia
a003996f-9792-4f8c-be6e-7717bb31d26d Portugal
f36dfeb3-7f3c-4de3-88e7-6ba60e1437d6 Greece
cb4f015c-653c-4cd0-9ba9-cbd051a6d402 Poland
4f717165-b39f-4d34-bd56-9d32f53e7b90 Bulgaria
2615b2d8-52f1-4833-ad21-dde46ceab0ab Sweden
7f2be7cf-ffd1-4298-b2e9-8b2a99f2558d Poland
ae34f419-f3cc-4a04-83bc-94282d77f473 Czech Republic
6f41e1ef-4bd7-487d-a75b-66c83dbbc85e Croatia
45d7d096-d02d-4296-9007-891e37dd6bfb Germany
d6dbed2c-f377-4f05-9da1-0172c137d0fb Sweden
2c8cf1da-2d32-46d7-957a-b0013e7f4ef3 Belgium
34dd787a-bc52-490b-8b51-9ab04c4bbd1c France
6fcfb675-5592-46ee-b2d9-a593ae23c83c Hungary
f6e965cc-970a-4645-b303-a2f3304367d3 Spain
Environmental
Environmental Information9AKK108467A6707
Ordering
Order Code US and CanadaZANQEGBE000A000000XX
EAN8015644752859
Minimum Order Quantity1 piece
Customs Tariff Number85362090
Dimensions
Product Net Width280 mm
Product Net Height296 mm
Product Net Depth / Length183 mm
Product Net Weight16 kg
Container Information
Package Level 1 Unitsbox 1 piece
Package Level 1 Width350 mm
Package Level 1 Height350 mm
Package Level 1 Depth / Length330 mm
Package Level 1 Gross Weight18 kg
Package Level 1 EAN8015644752859
Additional Information
Product Main TypeSACE Emax 2
Product NameAir Circuit Breaker
Product TypeAir Circuit Breaker
VersionF
CAD Dimensional Drawing1SDH001252R0042
Technical
Connecting Capacity1000 mm²
Current TypeAC
Electrical DurabilityUe =< 440 V 8000 cycle
Ue = 500 ... 690 V 8000 cycle
30 cycles per hour
Mechanical Durability20000 cycle
60 cycles per hour
Neutral Pole Current ([%Iu])100 %
Number of Poles4P
Power Loss78 W
Rated Current (In)1000 A
Rated Impulse Withstand Voltage (Uimp)acc. to IEC 60947-2 12 kV
Rated Insulation Voltage (Ui)AC 1000 V
Rated Operational Voltage690 V AC
Rated Service Short-Circuit Breaking Capacity (Ics)(220 V AC) 50 kA
(230 V AC) 50 kA
(380 V AC) 50 kA
(400 V AC) 50 kA
(415 V AC) 50 kA
(440 V AC) 50 kA
(500 V AC) 50 kA
(660 V AC) 50 kA
(690 V AC) 50 kA
Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics)100 %
Rated Short-time Withstand Current Low Voltage (Icw)for 1 s 50 kA
for 3 s 30 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)(400 V AC) 66 kA
(415 V AC) 66 kA
(440 V AC) 66 kA
(500 V AC) 50 kA
(525 V AC) 50 kA
(690 V AC) 50 kA
Rated Uninterrupted Current (Iu)1000 A
Rated Voltage (Ur)690 V
Recommended Screw DriverM12
ReleaseEkip Touch LSI
Release TypeEL
Short-Circuit Performance LevelN
StandardsIEC
Sub-typeE1.2
Suitable for IT NetworksYes, 690V
Terminal Connection TypeFront
Terminal TypeBolt
Tightening Torque45 N·m
Certificates and Declarations
ATEX CertificateNo certification needed
CSA CertificateNo certification needed
CSA Certificate (Intrinsic Safe)No certification needed
Data Sheet, Technical Information1SDC200023D0209
Declaration of Conformity - CE9AKK106713A5546
EU Data Act Compliance Declaration1SDH002560A1001
UL CertificateNo certification needed
VDE CertificateNo certification needed
Mechanical Drawings1SDH000999R0101
Wiring Diagram1SDM000091R0001
Instructions and Manuals1SDH000999R0002
Instructions and Manuals (Part 2)1SDH001316R1002
External Classifications and Standards
ETIM 9EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 10EC000228 - Power circuit-breaker for trafo/generator/installation protection
IDEA Granular Category Code (IGCC)4926 >> Air circuit breakers
Object Classification CodeQ
UNSPSC39121615
WEEE Category5. Small Equipment (No External Dimension More Than 50 cm)
eClassV11.1 : 27370409

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.