E1.2N 1000 Ekip G Touch LSIG 4p F F
Low-voltage industrial components > Power circuit-breaker for trafo/generator/installation protection
Rack "Megamax-Emax" > E1.2
Brand new product in its original packaging covered by the warranties and certifications provided by ABB
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2360 |
| Environmental Product Declaration - EPD | 9AKK108468A1900 |
| 9AKK108468A3028 | |
| Extended Product Lifetime | Lifetime Extension Services are Offered |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 76.4 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | d8255eed-ada9-4eba-b360-032727e13c78 India |
| Simplified SCIP | 6b4a67d7-55a5-41cd-a799-16b238ad9752 France |
| 31d1a79f-406a-484f-84f0-77254ac576ca Hungary | |
| 65541776-185b-4a3c-a1e4-0267ba5b6667 Hungary | |
| 9e0b9d6f-a296-4576-8bca-db87ec4a95d4 Poland | |
| 2abea467-cc65-409a-8341-2f9851f11888 Spain | |
| 6fe6a03b-0de4-4117-9422-c98a384901e5 Belgium | |
| 947cdc2e-149e-4268-b6a3-30d57b3a42f8 France | |
| 2e5e0314-eb21-4585-a518-f6117317cf09 Bulgaria | |
| f6ab1ef8-0b32-471b-97b9-099c2b7a9b2f Poland | |
| 06d17947-87f4-4ecf-8700-63e8d248dc53 Sweden | |
| 825d6166-a5ea-4197-8f96-a5d47b70bba9 Estonia | |
| ce0d4fd4-89bc-47dd-84c0-f555dca013b1 Greece | |
| f91d2cb9-75ab-4e36-b6b4-63e78c873b33 Sweden | |
| 184882b7-96c8-427b-94ab-8854f7eee6a5 Germany | |
| ef7a265f-567d-4b9a-8ec2-f32bfb92a01a Germany | |
| 80285d3a-cfa7-46b0-8efd-2140cf47adcf Portugal | |
| bee5ab42-c7fc-4189-a587-975576610aee Germany | |
| 6cbeb135-9a56-479f-b6ba-399f924eb89e Denmark | |
| 87735542-9689-455d-8152-1ea8ebe71c98 Germany | |
| 78cdddcd-e7ac-4273-881e-990a896ce085 Croatia | |
| da6c829d-2f85-4e56-aab6-70756341a31c Belgium | |
| b504d178-0d31-4a35-b941-bb42ca9ee5d7 Norway | |
| cc765267-5435-48f5-91c3-79286bc3e852 Finland | |
| 997232b3-5277-477b-8d3c-6f647654b970 Netherlands | |
| cd5345d1-c54b-47a1-977a-c13ed4ef6bea Germany | |
| 45cd9a2f-b1b0-4f8b-8cc2-4ccbf2c50775 Poland | |
| adfdd7e2-752f-486d-8329-3152af97f072 Czech Republic | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | ZANQEGBN200A000000XX |
| EAN | 8015644752873 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 280 mm |
| Product Net Height | 296 mm |
| Product Net Depth / Length | 183 mm |
| Product Net Weight | 16 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 350 mm |
| Package Level 1 Height | 350 mm |
| Package Level 1 Depth / Length | 330 mm |
| Package Level 1 Gross Weight | 18 kg |
| Package Level 1 EAN | 8015644752873 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | F |
| Technical | |
| Connecting Capacity | 1000 mm² |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 8000 cycle |
| Ue = 500 ... 690 V 8000 cycle | |
| 30 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 60 cycles per hour | |
| Neutral Pole Current ([%Iu]) | 100 % |
| Number of Poles | 4P |
| Power Loss | 78 W |
| Rated Current (In) | 1000 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 50 kA |
| (230 V AC) 50 kA | |
| (380 V AC) 50 kA | |
| (400 V AC) 50 kA | |
| (415 V AC) 50 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 50 kA | |
| (660 V AC) 50 kA | |
| (690 V AC) 50 kA | |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 100 % |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 50 kA |
| for 3 s 30 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 66 kA |
| (415 V AC) 66 kA | |
| (440 V AC) 66 kA | |
| (500 V AC) 50 kA | |
| (525 V AC) 50 kA | |
| (690 V AC) 50 kA | |
| Rated Uninterrupted Current (Iu) | 1000 A |
| Rated Voltage (Ur) | 690 V |
| Recommended Screw Driver | M12 |
| Release | Ekip G Touch LSIG |
| Release Type | EL |
| Short-Circuit Performance Level | N |
| Standards | IEC |
| Sub-type | E1.2 |
| Suitable for IT Networks | Yes, 690V |
| Terminal Connection Type | Front |
| Certificates and Declarations | |
| Data Sheet, Technical Information | 1SDC200023D0209 |
| Declaration of Conformity - CE | 9AKK106713A5546 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| Instructions and Manuals | 1SDH000999R0002 |
| Instructions and Manuals (Part 2) | 1SDH001316R1002 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| IDEA Granular Category Code (IGCC) | 4926 >> Air circuit breakers |
| Object Classification Code | Q |
| UNSPSC | 39121615 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |
| Feature Name | Feature Value |
|---|---|
| Rated permanent current Iu (EF001389) | 1000 A |
| Rated voltage (EF003977) | 690 V |
| Rated short-circuit breaking capacity Icu at 400 V, 50 Hz (EF007048) | 66 kA |
| Overload release current setting (EF002336) | 1000 A |
| Adjustment range short-term delayed short-circuit release (EF007129) | 10000 A |
| Adjustment range undelayed short-circuit release (EF007131) | 1500.0 A |
| Integrated earth fault protection (EF007296) | Yes |
| Type of electrical connection of main circuit (EF006819) | Bolt connection |
| Device construction (EF008240) | Built-in device fixed built-in technique |
| Suitable for DIN rail (top hat rail) mounting (EF007250) | No |
| DIN rail (top hat rail) mounting optional (EF008904) | No |
| Number of auxiliary contacts as normally closed contact (EF001377) | 0 |
| Number of auxiliary contacts as normally open contact (EF001376) | 0 |
| Number of auxiliary contacts as change-over contact (EF003531) | 4 |
| With switched-off indicator (EF007006) | Yes |
| With integrated under voltage release (EF001390) | No |
| Number of poles (EF001391) | 4 |
| Position of connection for main current circuit (EF006671) | Back |
| Type of control element (EF006976) | Push button |
| Complete device with protection unit (EF008906) | Yes |
| Motor drive integrated (EF006697) | No |
| Motor drive optional (EF007386) | Yes |
| Degree of protection (IP) (EF005474) | IP30 |
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOG EMAX 2 EN.pdf | 207 Mbytes |
|
| E1.2N 1000 Ekip G Touch LSIG 4p F F - ABB - E1.2N1000 - 1SDA071437R1 | 90 Kbytes |
![]() |
| E1.2N1000 1SDA071437R1 ABB E1.2N 1000 Ekip G Touch LSIG 4p F F | 75 Kbytes |
![]() |
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.