ANUNCIAR
1SDA071466R1 ABB E1.2C 1250 Ekip Touch LSIG 4p F F View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

1SDA071466R1 ABB E1.2C 1250 Ekip Touch LSIG 4p F F

1SDA071466R1

ABB

E1.2C 1250 Ekip Touch LSIG 4p F F

More details


Low-voltage industrial components > Power circuit-breaker for trafo/generator/installation protection

Rack "Megamax-Emax" > E1.2

Brand new product in its original packaging covered by the warranties and certifications provided by ABB

Total: $6,566.58
Unit price: $6,566.58
This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



ABB EcoSolutions
ABB EcoSolutionsYes
ABB Site Meeting Group Waste To Landfill TargetUL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions9AKK108468A2360
Environmental Product Declaration - EPD9AKK108468A1900
9AKK108468A3028
Extended Product LifetimeLifetime Extension Services are Offered
Recyclability Rate of the Product acc. to EN45555Design for Closing Resource Loops - Standard EN45555 - 76.4 %
Material Compliance
REACH Declaration9AKK108466A1425
RoHS Declaration9AKK108466A1424
RoHS InformationFollowing EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)9AKK108467A5658
Toxic Substances Control Act - TSCA9AKK108467A8326
SCIP1ac2222e-e9e8-4b77-87c1-7120965165c7 India
Simplified SCIP235a54e4-9f81-4e47-897e-bce0ffda1c76 Netherlands
617c8ffc-4439-4472-a2d6-f6c69e4f7567 Poland
d20dc963-772b-41dd-a7b0-d7837f4c734b Croatia
ecf58ea6-bec8-4111-a981-c37ae34fe4d6 Czech Republic
003aa279-02da-4447-b12f-e03faa4592f4 Hungary
c200c4e6-829a-4358-bd83-04e11f44a628 Hungary
eeded7bb-3de0-43ed-930b-90a21bd25e82 Estonia
eece2185-5d00-411a-89bf-c1c858b1c90d Spain
e2bb484c-92d5-47aa-bb4a-84ddd8f17050 Belgium
d8e3e909-18ac-419b-9e84-6d45a19a1f39 Portugal
53066d7c-2efd-430c-a05d-fb8fe20f83af Sweden
bad7d866-8970-48b2-b18d-04d3b6e30cb0 Germany
b6ff486a-e77f-4648-90ab-998075fe311d France
7177c275-4911-43f0-a18f-1a2791e03390 Greece
58496cd9-d02c-4a39-ba12-5aea00748495 Germany
ef915fd8-aa06-4d60-8548-c3228235d0b2 Bulgaria
f07a1bfa-790e-4c92-b608-53e6e90461ae France
3dce52b8-1772-4d1a-aa28-a3ea61423981 Sweden
2ba7a78e-18a3-4225-b969-05602f5dc1ef Poland
5cb625ca-05d6-448a-9ecb-019be2d67fa6 Norway
2e8309fd-9111-43b9-aa97-f8cdf25d33c1 Belgium
6b6fbd32-e106-434d-92e3-08fdd2ad3479 Poland
1b199ec1-b57a-4c3a-9b46-96f9261c1cd7 Germany
f4138b27-79a0-491d-859d-d340bed329fa Germany
710edc1e-d1ca-413d-80da-70aef149eb89 Denmark
40c9b195-d3ac-4c07-9e9c-ff17b043744c Finland
0c1b3949-1bd4-438e-94c5-172f0f4b23ca Germany
Environmental
Environmental Information9AKK108467A6707
Ordering
Order Code US and CanadaZACREHBF000A000000XX
EAN8015644753160
Minimum Order Quantity1 piece
Customs Tariff Number85362090
Dimensions
Product Net Width280 mm
Product Net Height296 mm
Product Net Depth / Length183 mm
Product Net Weight16 kg
Container Information
Package Level 1 Unitsbox 1 piece
Package Level 1 Width350 mm
Package Level 1 Height350 mm
Package Level 1 Depth / Length330 mm
Package Level 1 Gross Weight18 kg
Package Level 1 EAN8015644753160
Additional Information
Product Main TypeSACE Emax 2
Product NameAir Circuit Breaker
Product TypeAir Circuit Breaker
VersionF
CAD Dimensional Drawing1SDH001252R0042
Technical
Connecting Capacity1000 mm²
Current TypeAC
Electrical DurabilityUe =< 440 V 8000 cycle
Ue = 500 ... 690 V 6500 cycle
30 cycles per hour
Mechanical Durability20000 cycle
60 cycles per hour
Neutral Pole Current ([%Iu])100 %
Number of Poles4P
Power Loss122 W
Rated Current (In)1250 A
Rated Impulse Withstand Voltage (Uimp)acc. to IEC 60947-2 12 kV
Rated Insulation Voltage (Ui)AC 1000 V
Rated Operational Voltage690 V AC
Rated Service Short-Circuit Breaking Capacity (Ics)(220 V AC) 50 kA
(230 V AC) 50 kA
(380 V AC) 50 kA
(400 V AC) 50 kA
(415 V AC) 50 kA
(440 V AC) 50 kA
(500 V AC) 42 kA
(660 V AC) 42 kA
(690 V AC) 42 kA
Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics)100 %
Rated Short-time Withstand Current Low Voltage (Icw)for 1 s 42 kA
for 3 s 24 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)(400 V AC) 50 kA
(415 V AC) 50 kA
(440 V AC) 50 kA
(500 V AC) 42 kA
(525 V AC) 42 kA
(690 V AC) 42 kA
Rated Uninterrupted Current (Iu)1250 A
Rated Voltage (Ur)690 V
Recommended Screw DriverM12
ReleaseEkip Touch LSIG
Release TypeEL
Short-Circuit Performance LevelC
StandardsIEC
Sub-typeE1.2
Suitable for IT NetworksYes, 690V
Terminal Connection TypeFront
Terminal TypeBolt
Tightening Torque45 N·m
Certificates and Declarations
ATEX CertificateNo certification needed
CSA CertificateNo certification needed
CSA Certificate (Intrinsic Safe)No certification needed
Data Sheet, Technical Information1SDC200023D0209
Declaration of Conformity - CE9AKK106713A5546
EU Data Act Compliance Declaration1SDH002560A1001
UL CertificateNo certification needed
VDE CertificateNo certification needed
Mechanical Drawings1SDH000999R0101
Wiring Diagram1SDM000091R0001
Instructions and Manuals1SDH000999R0002
Instructions and Manuals (Part 2)1SDH001316R1002
External Classifications and Standards
ETIM 9EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 10EC000228 - Power circuit-breaker for trafo/generator/installation protection
IDEA Granular Category Code (IGCC)4926 >> Air circuit breakers
Object Classification CodeQ
UNSPSC39121615
WEEE Category5. Small Equipment (No External Dimension More Than 50 cm)
eClassV11.1 : 27370409

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.