Product successfully added to your shopping cart
1SDA071424R1
ABB
1
E1.2C 1000 Ekip Touch LI 4p F F
Low-voltage industrial components > Power circuit-breaker for trafo/generator/installation protection
Rack "Megamax-Emax" > E1.2
Brand new product in its original packaging covered by the warranties and certifications provided by ABB
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2360 |
| Environmental Product Declaration - EPD | 9AKK108468A1900 |
| 9AKK108468A3028 | |
| Extended Product Lifetime | Lifetime Extension Services are Offered |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 76.4 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | befe5437-a53b-4de7-9f75-9ab35c389830 Italy |
| Simplified SCIP | 5b3d6b96-b159-4a55-940e-d37884cf475e Sweden |
| c133bd12-a9f1-4e33-8716-1de1283d7a50 Germany | |
| b1fbafd2-11bb-4547-8bbd-0cb3306eb343 Hungary | |
| 166d833e-af56-46ab-8776-6ad6fd4bcd74 Croatia | |
| 7ec6e086-b2a1-42a4-99a3-7668d55500d9 Germany | |
| de0c3a2e-6b92-4f80-aede-af9b99ccaa4d France | |
| 4d57f0a1-d984-491a-a17c-8301c78a8a5d Greece | |
| 6b539bed-d753-4aba-9c4e-5fa6d1a30847 Germany | |
| ed5e9f65-bcb2-4a1b-b52d-e3de91df043e Germany | |
| 7e96bbe1-dc72-4753-b76c-44b50c643e0f Denmark | |
| 2d8e725e-d645-418b-8477-ce50688f7774 Norway | |
| f9b28684-3d43-4338-a33a-0907231c3def Portugal | |
| dcf2621b-ce53-4161-8b3f-a0e4614ebd0e Finland | |
| 2ccdc3b9-0a10-4568-b2da-32cd850c2b93 Czech Republic | |
| a355acba-640c-4371-aa91-2c1405c5a59d Poland | |
| 48593cd3-e900-4b81-b76a-5f265a87529a Netherlands | |
| d5aa9cb3-a872-4eca-836a-b79b1f08ef20 Poland | |
| b1fbafd2-11bb-4547-8bbd-0cb3306eb343 Hungary | |
| d12b971b-9164-4d4e-93dc-f138bee8fa4e France | |
| 7ec6e086-b2a1-42a4-99a3-7668d55500d9 Germany | |
| b86ea17d-617d-4f8a-a602-748d6a16a887 Hungary | |
| 8a81b65e-f754-4f5c-ab36-fc3588ec9105 Spain | |
| 789b0dee-ade8-4e75-8947-f691cb251015 Belgium | |
| f9b28684-3d43-4338-a33a-0907231c3def Portugal | |
| d2917e59-724a-47aa-ade7-11ba41ca7675 Bulgaria | |
| a355acba-640c-4371-aa91-2c1405c5a59d Poland | |
| 2ccdc3b9-0a10-4568-b2da-32cd850c2b93 Czech Republic | |
| f60ef63a-30c0-4706-af7d-557d8dfdff16 Estonia | |
| 4d57f0a1-d984-491a-a17c-8301c78a8a5d Greece | |
| f60ef63a-30c0-4706-af7d-557d8dfdff16 Estonia | |
| b86ea17d-617d-4f8a-a602-748d6a16a887 Hungary | |
| 48593cd3-e900-4b81-b76a-5f265a87529a Netherlands | |
| 0f089b8f-b934-4801-9e8b-56e0ced7819d Poland | |
| de0c3a2e-6b92-4f80-aede-af9b99ccaa4d France | |
| c133bd12-a9f1-4e33-8716-1de1283d7a50 Germany | |
| 5b3d6b96-b159-4a55-940e-d37884cf475e Sweden | |
| 8a81b65e-f754-4f5c-ab36-fc3588ec9105 Spain | |
| f234c862-2102-492a-9bf4-8a7d60cc1147 Sweden | |
| e29dbb63-0ba1-4b91-a229-69a390636eb2 Germany | |
| 166d833e-af56-46ab-8776-6ad6fd4bcd74 Croatia | |
| 2fda21c9-ac22-44d0-9417-35456e336267 Belgium | |
| dcf2621b-ce53-4161-8b3f-a0e4614ebd0e Finland | |
| f234c862-2102-492a-9bf4-8a7d60cc1147 Sweden | |
| 0f089b8f-b934-4801-9e8b-56e0ced7819d Poland | |
| ed5e9f65-bcb2-4a1b-b52d-e3de91df043e Germany | |
| d12b971b-9164-4d4e-93dc-f138bee8fa4e France | |
| d5aa9cb3-a872-4eca-836a-b79b1f08ef20 Poland | |
| 6b539bed-d753-4aba-9c4e-5fa6d1a30847 Germany | |
| 7e96bbe1-dc72-4753-b76c-44b50c643e0f Denmark | |
| d2917e59-724a-47aa-ade7-11ba41ca7675 Bulgaria | |
| e29dbb63-0ba1-4b91-a229-69a390636eb2 Germany | |
| 2d8e725e-d645-418b-8477-ce50688f7774 Norway | |
| 2fda21c9-ac22-44d0-9417-35456e336267 Belgium | |
| 789b0dee-ade8-4e75-8947-f691cb251015 Belgium | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | ZACQEGBD000A000000XX |
| EAN | 8015644752743 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 280 mm |
| Product Net Height | 296 mm |
| Product Net Depth / Length | 183 mm |
| Product Net Weight | 16 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 350 mm |
| Package Level 1 Height | 350 mm |
| Package Level 1 Depth / Length | 330 mm |
| Package Level 1 Gross Weight | 18 kg |
| Package Level 1 EAN | 8015644752743 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | F |
| CAD Dimensional Drawing | 1SDH001252R0042 |
| Technical | |
| Connecting Capacity | 1000 mm² |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 8000 cycle |
| Ue = 500 ... 690 V 8000 cycle | |
| 30 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 60 cycles per hour | |
| Neutral Pole Current ([%Iu]) | 100 % |
| Number of Poles | 4P |
| Power Loss | 78 W |
| Rated Current (In) | 1000 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 50 kA |
| (230 V AC) 50 kA | |
| (380 V AC) 50 kA | |
| (400 V AC) 50 kA | |
| (415 V AC) 50 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 42 kA | |
| (660 V AC) 42 kA | |
| (690 V AC) 42 kA | |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 100 % |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 42 kA |
| for 3 s 24 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 50 kA |
| (415 V AC) 50 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 42 kA | |
| (525 V AC) 42 kA | |
| (690 V AC) 42 kA | |
| Rated Uninterrupted Current (Iu) | 1000 A |
| Rated Voltage (Ur) | 690 V |
| Recommended Screw Driver | M12 |
| Release | Ekip Touch LI |
| Release Type | EL |
| Short-Circuit Performance Level | C |
| Standards | IEC |
| Sub-type | E1.2 |
| Suitable for IT Networks | Yes, 690V |
| Terminal Connection Type | Front |
| Terminal Type | Bolt |
| Tightening Torque | 45 N·m |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| CSA Certificate | No certification needed |
| CSA Certificate (Intrinsic Safe) | No certification needed |
| Data Sheet, Technical Information | 1SDC200023D0209 |
| Declaration of Conformity - CE | 9AKK106713A5546 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Mechanical Drawings | 1SDH000999R0101 |
| Wiring Diagram | 1SDM000091R0001 |
| Instructions and Manuals | 1SDH000999R0002 |
| Instructions and Manuals (Part 2) | 1SDH001316R1002 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| IDEA Granular Category Code (IGCC) | 4926 >> Air circuit breakers |
| Object Classification Code | Q |
| UNSPSC | 39121615 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |
| Feature Name | Feature Value |
|---|---|
| Rated permanent current Iu (EF001389) | 1000 A |
| Rated voltage (EF003977) | 690 V |
| Rated short-circuit breaking capacity Icu at 400 V, 50 Hz (EF007048) | 50 kA |
| Overload release current setting (EF002336) | 1000 A |
| Adjustment range undelayed short-circuit release (EF007131) | 1500.0 A |
| Integrated earth fault protection (EF007296) | No |
| Type of electrical connection of main circuit (EF006819) | Bolt connection |
| Device construction (EF008240) | Built-in device fixed built-in technique |
| Suitable for DIN rail (top hat rail) mounting (EF007250) | No |
| DIN rail (top hat rail) mounting optional (EF008904) | No |
| Number of auxiliary contacts as normally closed contact (EF001377) | 0 |
| Number of auxiliary contacts as normally open contact (EF001376) | 0 |
| Number of auxiliary contacts as change-over contact (EF003531) | 4 |
| With switched-off indicator (EF007006) | Yes |
| With integrated under voltage release (EF001390) | No |
| Number of poles (EF001391) | 4 |
| Position of connection for main current circuit (EF006671) | Back |
| Type of control element (EF006976) | Push button |
| Complete device with protection unit (EF008906) | Yes |
| Motor drive integrated (EF006697) | No |
| Motor drive optional (EF007386) | Yes |
| Degree of protection (IP) (EF005474) | IP30 |
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOG EMAX 2 EN.pdf | 207 Mbytes |
|
| E1.2C 1000 Ekip Touch LI 4p F F - ABB - E1.2C1000 - 1SDA071424R1 | 89 Kbytes |
![]() |
| E1.2C1000 1SDA071424R1 ABB E1.2C 1000 Ekip Touch LI 4p F F | 75 Kbytes |
![]() |
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.