ANUNCIAR
1SDA071331R1 ABB E1.2B 630 Ekip Dip LI 4p F F View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

1SDA071331R1 ABB E1.2B 630 Ekip Dip LI 4p F F

1SDA071331R1

ABB

E1.2B 630 Ekip Dip LI 4p F F

More details


Low-voltage industrial components > Power circuit-breaker for trafo/generator/installation protection

Rack "Megamax-Emax" > E1.2

Brand new product in its original packaging covered by the warranties and certifications provided by ABB

Total: $3,435.16
Unit price: $3,435.16
This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



ABB EcoSolutions
ABB EcoSolutionsYes
ABB Site Meeting Group Waste To Landfill TargetUL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions9AKK108468A2360
Environmental Product Declaration - EPD9AKK108468A1900
9AKK108468A3028
Extended Product LifetimeLifetime Extension Services are Offered
Recyclability Rate of the Product acc. to EN45555Design for Closing Resource Loops - Standard EN45555 - 76.4 %
Material Compliance
REACH Declaration9AKK108466A1425
RoHS Declaration9AKK108466A1424
RoHS InformationFollowing EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)9AKK108467A5658
Toxic Substances Control Act - TSCA9AKK108467A8326
SCIP3681d6f9-45c8-47f2-b593-2c7a550c0982 Italy
Simplified SCIPd2bb70d3-15c3-44f8-bca7-6a06df48f7e5 Belgium
116ef8a6-7f4a-43ef-a530-741062e12807 Hungary
88adcbb1-4f4b-47ff-93ac-d62075d974b8 Finland
d099fc28-9750-4a01-95ad-8a26ee8b79bc Germany
8c3b8489-5f50-456c-b5b1-3b07972303d0 Belgium
dd8b3eb7-1309-4aac-a2dd-643c320d76f8 Croatia
38a0112b-c177-4a89-ada2-3a8e93669e80 Poland
14123592-2204-4f8c-8a09-a897303527b5 Czech Republic
70b32e73-0a72-4b75-bd3b-fa335f2cf02b Germany
a8484234-4b84-4f91-92ce-6076a4838cce Sweden
95d61820-27d3-4e5b-a629-54bbbf0abb82 Poland
2170a182-b45e-4173-bb85-632a5c1d8dea France
19328ae0-b937-49c5-8562-0a684faeda48 Poland
c5f0edc0-eb46-4aab-a5cd-bf2c0db784d0 Estonia
6f019d84-8a80-41a0-8cec-796c4342582b Bulgaria
3c3f0232-2331-43da-800c-0faee14b58f2 Norway
62d8ef36-f99f-4544-a79d-09ca69fb2cd5 Denmark
890333a8-be94-4b5b-a48d-acad406e781c Germany
472b85a7-d5ed-4d01-82ea-ba02ce8e0cdc Portugal
b3243704-5481-4ad8-9607-4ee4df2c45e3 Hungary
7ca1ceed-6bc5-4fc6-808e-d7f6741262ac Spain
15ae5d02-1f85-4d1e-9ddc-5efe707f384c Netherlands
415ff63e-311f-4c64-a03e-1b3619655315 Greece
2ef6f729-f94d-4c22-a47d-9530c6eabba1 Sweden
049165e0-0bf6-4f9b-b3ba-7f86fc31d30d Germany
9d57c101-8280-476b-a65b-703dd3c02f23 Germany
0e7223dd-21bc-4d42-a468-23d76a508c5a France
Environmental
Environmental Information9AKK108467A6707
Ordering
Order Code US and CanadaZABNEEBA000A000000XX
EAN8015644751814
Minimum Order Quantity1 piece
Customs Tariff Number85362090
Dimensions
Product Net Width280 mm
Product Net Height296 mm
Product Net Depth / Length183 mm
Product Net Weight16 kg
Container Information
Package Level 1 Unitsbox 1 piece
Package Level 1 Width350 mm
Package Level 1 Height350 mm
Package Level 1 Depth / Length330 mm
Package Level 1 Gross Weight18 kg
Package Level 1 EAN8015644751814
Additional Information
Product Main TypeSACE Emax 2
Product NameAir Circuit Breaker
Product TypeAir Circuit Breaker
VersionF
CAD Dimensional Drawing1SDH001252R0042
Technical
Connecting Capacity400 mm²
Current TypeAC
Electrical DurabilityUe =< 440 V 8000 cycle
Ue = 500 ... 690 V 8000 cycle
30 cycles per hour
Mechanical Durability20000 cycle
60 cycles per hour
Neutral Pole Current ([%Iu])100 %
Number of Poles4P
Power Loss31 W
Rated Current (In)630 A
Rated Impulse Withstand Voltage (Uimp)acc. to IEC 60947-2 12 kV
Rated Insulation Voltage (Ui)AC 1000 V
Rated Operational Voltage690 V AC
Rated Service Short-Circuit Breaking Capacity (Ics)(220 V AC) 42 kA
(230 V AC) 42 kA
(380 V AC) 42 kA
(400 V AC) 42 kA
(415 V AC) 42 kA
(440 V AC) 42 kA
(500 V AC) 42 kA
(660 V AC) 42 kA
(690 V AC) 42 kA
Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics)100 %
Rated Short-time Withstand Current Low Voltage (Icw)for 1 s 42 kA
for 3 s 24 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)(400 V AC) 42 kA
(415 V AC) 42 kA
(440 V AC) 42 kA
(500 V AC) 42 kA
(525 V AC) 42 kA
(690 V AC) 42 kA
Rated Uninterrupted Current (Iu)630 A
Rated Voltage (Ur)690 V
Recommended Screw DriverM12
ReleaseEkip Dip LI
Release TypeEL
Short-Circuit Performance LevelB
StandardsIEC
Sub-typeE1.2
Suitable for IT NetworksYes, 690V
Terminal Connection TypeFront
Terminal TypeBolt
Tightening Torque45 N·m
Certificates and Declarations
ATEX CertificateNo certification needed
CSA CertificateNo certification needed
CSA Certificate (Intrinsic Safe)No certification needed
Data Sheet, Technical Information1SDC200023D0209
Declaration of Conformity - CE9AKK106713A5546
EU Data Act Compliance Declaration1SDH002560A1001
UL CertificateNo certification needed
VDE CertificateNo certification needed
Mechanical Drawings1SDH000999R0101
Wiring Diagram1SDM000091R0001
Instructions and Manuals1SDH000999R0002
External Classifications and Standards
ETIM 9EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 10EC000228 - Power circuit-breaker for trafo/generator/installation protection
IDEA Granular Category Code (IGCC)4926 >> Air circuit breakers
Object Classification CodeQ
UNSPSC39121615
WEEE Category5. Small Equipment (No External Dimension More Than 50 cm)
eClassV11.1 : 27370409

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.