Product successfully added to your shopping cart
1SDA071452R1
ABB
1
E1.2B 1250 Ekip Dip LSI 4p F F
Low-voltage industrial components > Power circuit-breaker for trafo/generator/installation protection
Rack "Megamax-Emax" > E1.2
Brand new product in its original packaging covered by the warranties and certifications provided by ABB
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2360 |
| Environmental Product Declaration - EPD | 9AKK108468A1900 |
| 9AKK108468A3028 | |
| Extended Product Lifetime | Lifetime Extension Services are Offered |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 76.4 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 3970fd65-e818-4737-8598-875771e1f926 Italy |
| Simplified SCIP | 54d4c673-7956-4b39-9ed4-931e2ec730be Poland |
| beb1bcec-a2fe-4448-9dc9-d49c681471c7 France | |
| a463b67c-f7e7-4da6-8d1b-2fb1459e78dd Sweden | |
| dfa29e50-0cec-4dba-af43-a4cc024a01dd Germany | |
| ccf050ac-9993-4cf9-833b-4d136c203337 France | |
| c4869521-0663-4e55-b285-75f42eb8f7eb Greece | |
| 9fef9031-e83b-4287-83d6-b2965f281fa9 Hungary | |
| 11b726df-9b85-4030-92c5-e92bf9d1168a Estonia | |
| 11b726df-9b85-4030-92c5-e92bf9d1168a Estonia | |
| 43890ef3-d36d-4c3e-b81d-d5b826012bbc Netherlands | |
| 9fef9031-e83b-4287-83d6-b2965f281fa9 Hungary | |
| 2322a9ab-eedf-4f1e-83ff-8c3b99a5c2c4 Norway | |
| 621e45b2-336f-424c-a897-1150a9ab1c59 Denmark | |
| 93453d93-2f93-4020-b17a-e2a7de047db1 Germany | |
| 27da68da-87b7-4ce3-8fae-a20036bd1758 Finland | |
| ea60118b-7457-48bc-9647-6c40cd2bccf7 Sweden | |
| d0d6e901-4c08-46de-a6ae-6aba193d0994 Germany | |
| 2a6d090c-5a66-4919-b25c-9bb8cf703030 Croatia | |
| 868a40f4-ca19-47ce-b657-9da091e675b9 Poland | |
| 2322a9ab-eedf-4f1e-83ff-8c3b99a5c2c4 Norway | |
| d0d6e901-4c08-46de-a6ae-6aba193d0994 Germany | |
| 66b4c120-6a5f-4aee-9cb4-b3348707a27a Germany | |
| 66b4c120-6a5f-4aee-9cb4-b3348707a27a Germany | |
| 621e45b2-336f-424c-a897-1150a9ab1c59 Denmark | |
| 54d4c673-7956-4b39-9ed4-931e2ec730be Poland | |
| 93453d93-2f93-4020-b17a-e2a7de047db1 Germany | |
| eaae944b-4daf-49c5-bab4-ebd05ecca884 Poland | |
| 58d77ec8-cf7c-4d13-b0ce-d3b5cb5cbae3 Belgium | |
| c52dd752-9410-47d9-9188-0fa1afc81765 Germany | |
| eac52095-9fce-421c-a87a-76e256daf9cf Hungary | |
| dfa29e50-0cec-4dba-af43-a4cc024a01dd Germany | |
| c52dd752-9410-47d9-9188-0fa1afc81765 Germany | |
| 6fe32538-86a3-4972-865c-af13d6483a67 Bulgaria | |
| 1163b533-9cc6-4d48-a7e3-056851916157 Czech Republic | |
| ea60118b-7457-48bc-9647-6c40cd2bccf7 Sweden | |
| beb1bcec-a2fe-4448-9dc9-d49c681471c7 France | |
| 1163b533-9cc6-4d48-a7e3-056851916157 Czech Republic | |
| 27da68da-87b7-4ce3-8fae-a20036bd1758 Finland | |
| 32e99bbb-6f23-46c7-bf2d-22af3a8eecbe Portugal | |
| eac52095-9fce-421c-a87a-76e256daf9cf Hungary | |
| 32e99bbb-6f23-46c7-bf2d-22af3a8eecbe Portugal | |
| 868a40f4-ca19-47ce-b657-9da091e675b9 Poland | |
| fe8ab6a3-c8cb-429e-b042-627dc21a1d3b Belgium | |
| 58d77ec8-cf7c-4d13-b0ce-d3b5cb5cbae3 Belgium | |
| eaae944b-4daf-49c5-bab4-ebd05ecca884 Poland | |
| 43890ef3-d36d-4c3e-b81d-d5b826012bbc Netherlands | |
| 6fe32538-86a3-4972-865c-af13d6483a67 Bulgaria | |
| c2a57317-0b5c-485b-92ac-d3f6f05d8d3d Spain | |
| fe8ab6a3-c8cb-429e-b042-627dc21a1d3b Belgium | |
| ccf050ac-9993-4cf9-833b-4d136c203337 France | |
| c2a57317-0b5c-485b-92ac-d3f6f05d8d3d Spain | |
| c4869521-0663-4e55-b285-75f42eb8f7eb Greece | |
| 2a6d090c-5a66-4919-b25c-9bb8cf703030 Croatia | |
| a463b67c-f7e7-4da6-8d1b-2fb1459e78dd Sweden | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | ZABREHBB000A000000XX |
| EAN | 8015644753023 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 280 mm |
| Product Net Height | 296 mm |
| Product Net Depth / Length | 183 mm |
| Product Net Weight | 16 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 350 mm |
| Package Level 1 Height | 350 mm |
| Package Level 1 Depth / Length | 330 mm |
| Package Level 1 Gross Weight | 18 kg |
| Package Level 1 EAN | 8015644753023 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | F |
| CAD Dimensional Drawing | 1SDH001252R0042 |
| Technical | |
| Connecting Capacity | 1000 mm² |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 8000 cycle |
| Ue = 500 ... 690 V 6500 cycle | |
| 30 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 60 cycles per hour | |
| Neutral Pole Current ([%Iu]) | 100 % |
| Number of Poles | 4P |
| Power Loss | 122 W |
| Rated Current (In) | 1250 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 42 kA |
| (230 V AC) 42 kA | |
| (380 V AC) 42 kA | |
| (400 V AC) 42 kA | |
| (415 V AC) 42 kA | |
| (440 V AC) 42 kA | |
| (500 V AC) 42 kA | |
| (660 V AC) 42 kA | |
| (690 V AC) 42 kA | |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 100 % |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 42 kA |
| for 3 s 24 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 42 kA |
| (415 V AC) 42 kA | |
| (440 V AC) 42 kA | |
| (500 V AC) 42 kA | |
| (525 V AC) 42 kA | |
| (690 V AC) 42 kA | |
| Rated Uninterrupted Current (Iu) | 1250 A |
| Rated Voltage (Ur) | 690 V |
| Recommended Screw Driver | M12 |
| Release | Ekip Dip LSI |
| Release Type | EL |
| Short-Circuit Performance Level | B |
| Standards | IEC |
| Sub-type | E1.2 |
| Suitable for IT Networks | Yes, 690V |
| Terminal Connection Type | Front |
| Terminal Type | Bolt |
| Tightening Torque | 45 N·m |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| CSA Certificate | No certification needed |
| CSA Certificate (Intrinsic Safe) | No certification needed |
| Data Sheet, Technical Information | 1SDC200023D0209 |
| Declaration of Conformity - CE | 9AKK106713A5546 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Mechanical Drawings | 1SDH000999R0101 |
| Wiring Diagram | 1SDM000091R0001 |
| Instructions and Manuals | 1SDH000999R0002 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| IDEA Granular Category Code (IGCC) | 4926 >> Air circuit breakers |
| Object Classification Code | Q |
| UNSPSC | 39121615 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |
| Feature Name | Feature Value |
|---|---|
| Rated permanent current Iu (EF001389) | 1250 A |
| Rated voltage (EF003977) | 690 V |
| Rated short-circuit breaking capacity Icu at 400 V, 50 Hz (EF007048) | 42 kA |
| Overload release current setting (EF002336) | 1250 A |
| Adjustment range short-term delayed short-circuit release (EF007129) | 12500 A |
| Adjustment range undelayed short-circuit release (EF007131) | 1875.0 A |
| Integrated earth fault protection (EF007296) | No |
| Type of electrical connection of main circuit (EF006819) | Bolt connection |
| Device construction (EF008240) | Built-in device fixed built-in technique |
| Suitable for DIN rail (top hat rail) mounting (EF007250) | No |
| DIN rail (top hat rail) mounting optional (EF008904) | No |
| Number of auxiliary contacts as normally closed contact (EF001377) | 0 |
| Number of auxiliary contacts as normally open contact (EF001376) | 0 |
| Number of auxiliary contacts as change-over contact (EF003531) | 4 |
| With switched-off indicator (EF007006) | Yes |
| With integrated under voltage release (EF001390) | No |
| Number of poles (EF001391) | 4 |
| Position of connection for main current circuit (EF006671) | Back |
| Type of control element (EF006976) | Push button |
| Complete device with protection unit (EF008906) | Yes |
| Motor drive integrated (EF006697) | No |
| Motor drive optional (EF007386) | Yes |
| Degree of protection (IP) (EF005474) | IP30 |
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOG EMAX 2 EN.pdf | 207 Mbytes |
|
| E1.2B 1250 Ekip Dip LSI 4p F F - ABB - E1.2B1250 - 1SDA071452R1 | 89 Kbytes |
![]() |
| E1.2B1250 1SDA071452R1 ABB E1.2B 1250 Ekip Dip LSI 4p F F | 76 Kbytes |
![]() |
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.