Product successfully added to your shopping cart
1SBL397001R1300
ABB
1
Low-voltage industrial components > Power contactor, AC switching
Contactors and overload relays > AF contactors 40A to 100A
Brand new product in its original packaging covered by the warranties and certifications provided by ABB
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| Ordering | |
|---|---|
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85364900 |
| Popular Downloads | |
| EPLAN Data | 9AAC175975_EPLAN |
| Data Sheet, Technical Information | 1SBC100214C0202 |
| Instructions and Manuals | 1SBC101036M6801 |
| Instructions and Manuals (Part 2) | 1SAC200017M0002 |
| CAD Dimensional Drawing | 2CDC001079B0201 |
| Dimensions | |
| Product Net Width | 70 mm |
| Product Net Depth / Length | 116 mm |
| Product Net Height | 125.5 mm |
| Product Net Weight | 1.17 kg |
| Technical | |
| Number of Main Contacts NO | 3 |
| Number of Main Contacts NC | 0 |
| Number of Auxiliary Contacts NO | 0 |
| Number of Auxiliary Contacts NC | 0 |
| Number of Poles | 3P |
| Standards | IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60335-2-40 LZGH2 A2L, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60335-2-40 LZGH2 A2L, CSA C22.2 No. 60947-1:22, CSA C22.2 No. 60947-4-1:22 |
| Rated Operational Voltage | Main Circuit 1000 V |
| Rated Frequency (f) | Control Circuit 50 / 60 Hz |
| Main Circuit 50 / 60 Hz | |
| Conventional Free-air Thermal Current (Ith) | acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 130 A |
| Rated Operational Current AC-1 (Ie) | (690 V) 40 °C 125 A |
| (690 V) 60 °C 100 A | |
| (690 V) 70 °C 85 A | |
| Rated Operational Current AC-3 (Ie) | (415 V) 60 °C 80 A |
| (440 V) 60 °C 80 A | |
| (500 V) 60 °C 65 A | |
| (690 V) 60 °C 49 A | |
| (1000 V) 60 °C 25 A | |
| (380 / 400 V) 60 °C 80 A | |
| (220 / 230 / 240 V) 60 °C 80 A | |
| Rated Operational Current AC-3e (Ie) | (415 V) 60 °C 80 A |
| (440 V) 60 °C 80 A | |
| (500 V) 60 °C 65 A | |
| (690 V) 60 °C 49 A | |
| (380 / 400 V) 60 °C 80 A | |
| (220 / 230 / 240 V) 60 °C 80 A | |
| Rated Operational Current DC-1 (Ie) | (110 V) 2 Poles in Series, 40 °C 125 A |
| (110 V) 2 Poles in Series, 60 °C 100 A | |
| (110 V) 2 Poles in Series, 70 °C 85 A | |
| (110 V) 3 Poles in Series, 40 °C 125 A | |
| (110 V) 3 Poles in Series, 60 °C 100 A | |
| (110 V) 3 Poles in Series, 70 °C 85 A | |
| (220 V) 3 Poles in Series, 40 °C 125 A | |
| (220 V) 3 Poles in Series, 60 °C 100 A | |
| (220 V) 3 Poles in Series, 70 °C 85 A | |
| (72 V) 1-Pole, 40 °C 125 A | |
| (72 V) 1-Pole, 60 °C 100 A | |
| (72 V) 1-Pole, 70 °C 85 A | |
| (72 V) 2 Poles in Series, 40 °C 125 A | |
| (72 V) 2 Poles in Series, 60 °C 100 A | |
| (72 V) 2 Poles in Series, 70 °C 85 A | |
| (72 V) 3 Poles in Series, 40 °C 125 A | |
| (72 V) 3 Poles in Series, 60 °C 100 A | |
| (72 V) 3 Poles in Series, 70 °C 85 A | |
| Rated Operational Current DC-3 (Ie) | (110 V) 2 Poles in Series, 40 °C 125 A |
| (110 V) 2 Poles in Series, 60 °C 100 A | |
| (110 V) 2 Poles in Series, 70 °C 85 A | |
| (110 V) 3 Poles in Series, 40 °C 125 A | |
| (110 V) 3 Poles in Series, 60 °C 100 A | |
| (110 V) 3 Poles in Series, 70 °C 85 A | |
| (220 V) 3 Poles in Series, 40 °C 125 A | |
| (220 V) 3 Poles in Series, 60 °C 100 A | |
| (220 V) 3 Poles in Series, 70 °C 85 A | |
| (72 V) 1-Pole, 40 °C 125 A | |
| (72 V) 1-Pole, 60 °C 100 A | |
| (72 V) 1-Pole, 70 °C 85 A | |
| (72 V) 2 Poles in Series, 40 °C 125 A | |
| (72 V) 2 Poles in Series, 60 °C 100 A | |
| (72 V) 2 Poles in Series, 70 °C 85 A | |
| (72 V) 3 Poles in Series, 40 °C 125 A | |
| (72 V) 3 Poles in Series, 60 °C 100 A | |
| (72 V) 3 Poles in Series, 70 °C 85 A | |
| Rated Operational Current DC-5 (Ie) | (110 V) 2 Poles in Series, 40 °C 125 A |
| (110 V) 2 Poles in Series, 60 °C 100 A | |
| (110 V) 2 Poles in Series, 70 °C 85 A | |
| (110 V) 3 Poles in Series, 40 °C 125 A | |
| (110 V) 3 Poles in Series, 60 °C 100 A | |
| (110 V) 3 Poles in Series, 70 °C 85 A | |
| (220 V) 3 Poles in Series, 40 °C 125 A | |
| (220 V) 3 Poles in Series, 60 °C 100 A | |
| (220 V) 3 Poles in Series, 70 °C 85 A | |
| (72 V) 1-Pole, 40 °C 125 A | |
| (72 V) 1-Pole, 60 °C 100 A | |
| (72 V) 1-Pole, 70 °C 85 A | |
| (72 V) 2 Poles in Series, 40 °C 125 A | |
| (72 V) 2 Poles in Series, 60 °C 100 A | |
| (72 V) 2 Poles in Series, 70 °C 85 A | |
| (72 V) 3 Poles in Series, 40 °C 125 A | |
| (72 V) 3 Poles in Series, 60 °C 100 A | |
| (72 V) 3 Poles in Series, 70 °C 85 A | |
| Rated Operational Power AC-3 (Pe) | (400 V) 37 kW |
| (415 V) 45 kW | |
| (440 V) 45 kW | |
| (500 V) 45 kW | |
| (690 V) 45 kW | |
| (1000 V) 35 kW | |
| (380 / 400 V) 37 kW | |
| (220 / 230 / 240 V) 22 kW | |
| Rated Operational Power AC-3e (Pe) | (415 V) 45 kW |
| (440 V) 45 kW | |
| (500 V) 45 kW | |
| (690 V) 45 kW | |
| (380 / 400 V) 37 kW | |
| (220 / 230 / 240 V) 22 kW | |
| Rated Short-time Withstand Current Low Voltage (Icw) | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 780 A |
| at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 140 A | |
| at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 300 A | |
| at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1200 A | |
| at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 450 A | |
| Maximum Breaking Capacity | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1150 A |
| cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 750 A | |
| Rated Insulation Voltage (Ui) | acc. to IEC 60947-4-1 1000 V |
| acc. to UL/CSA 600 V | |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Maximum Electrical Switching Frequency | (AC-1) 600 cycles per hour |
| (AC-2 / AC-4) 150 cycles per hour | |
| (AC-3) 1200 cycles per hour | |
| Maximum Mechanical Switching Frequency | 3600 cycles per hour |
| Rated Control Circuit Voltage (Uc) | 50 Hz 100 ... 250 V |
| 60 Hz 100 ... 250 V | |
| DC Operation 100 ... 250 V | |
| Coil Consumption | Average Holding Value 50 / 60 Hz 4 V·A |
| Average Holding Value 50 Hz 4 V·A | |
| Average Holding Value 60 Hz 4 V·A | |
| Average Holding Value DC 2 W | |
| Average Holding Value, from Warm State 2 W | |
| Power Loss | at Rated Operating Conditions AC-1 per Pole 7.6 W |
| at Rated Operating Conditions AC-3 per Pole 3 W | |
| Operate Time | Between Coil De-energization and NC Contact Closing 19 ... 105 ms |
| Between Coil De-energization and NO Contact Opening 17 ... 100 ms | |
| Between Coil Energization and NC Contact Opening 38 ... 95 ms | |
| Between Coil Energization and NO Contact Closing 42 ... 100 ms | |
| Mounting on DIN Rail | TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 |
| Mounting by Screws (not supplied) | 2 x M4 or 2 x M6 Screws Placed Diagonally |
| Connecting Capacity Main Circuit | Flexible with Ferrule 1/2x 6 ... 50 mm² |
| Flexible with Insulated Ferrule 1/2x 6 ... 50 mm² | |
| Rigid Stranded 1x 6 ... 70 mm² | |
| Rigid Stranded 2x 6 ... 50 mm² | |
| Connecting Capacity Control Circuit | Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² |
| Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² | |
| Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² | |
| Rigid Solid 1/2x 1 ... 2.5 mm² | |
| Rigid Stranded 1/2x 1 ... 2.5 mm² | |
| Wire Stripping Length | Control Circuit 10 mm |
| Main Circuit 17 mm | |
| Degree of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 |
| acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10 | |
| Recommended Screw Driver | Pozidriv PZ |
| Tightening Torque | Control Circuit 1.2 N·m |
| Main Circuit 6 N·m | |
| Terminal Type | Screw Terminals |
| Product Name | Block Contactor |
| Technical UL/CSA | |
| NEMA Size | 3 |
| Continuous Current Rating NEMA | 90 A |
| Horsepower Rating NEMA | (200 V AC) Three Phase 25 Hp |
| (230 V AC) Three Phase 30 Hp | |
| (460 V AC) Three Phase 50 Hp | |
| (575 V AC) Three Phase 50 Hp | |
| Maximum Operating Voltage UL/CSA | Main Circuit 600 V |
| General Use Rating UL/CSA | (600 V AC) 105 A |
| Horsepower Rating UL/CSA | (120 V AC) Single Phase 7-1/2 hp |
| (200 ... 208 V AC) Three Phase 25 hp | |
| (220 ... 240 V AC) Three Phase 30 hp | |
| (240 V AC) Single Phase 15 hp | |
| (440 ... 480 V AC) Three Phase 60 hp | |
| (550 ... 600 V AC) Three Phase 75 hp | |
| Connecting Capacity Main Circuit UL/CSA | Rigid Stranded 1/2x 6-1 AWG |
| Connecting Capacity Control Circuit UL/CSA | Rigid Solid 1/2x 18-14 AWG |
| Rigid Stranded 1/2x 18-14 AWG | |
| Tightening Torque UL/CSA | Control Circuit 11 in·lb |
| Main Circuit 53 in·lb | |
| Full Load Amps Motor Use | (120 V AC) Single Phase 80 A |
| (200 ... 208 V AC) Three Phase 78.2 A | |
| (220 ... 240 V AC) Three Phase 80 A | |
| (240 V AC) Single Phase 68 A | |
| (440 ... 480 V AC) Three Phase 77 A | |
| (550 ... 600 V AC) Three Phase 77 A | |
| Environmental | |
| Ambient Air Temperature | Close to Contactor Fitted with Thermal O/L Relay -40 ... 70 °C |
| Close to Contactor without Thermal O/L Relay -40 ... 70 °C | |
| Close to Contactor for Storage -60 ... +80 °C | |
| Climatic Withstand | Category B according to IEC 60947-1 Annex Q |
| Maximum Operating Altitude Permissible | Without Derating 3000 m |
| Resistance to Shock acc. to IEC 60068-2-27 | Closed, Shock Direction: A 25 g |
| Closed, Shock Direction: B1 25 g | |
| Closed, Shock Direction: B2 15 g | |
| Closed, Shock Direction: C1 25 g | |
| Closed, Shock Direction: C2 25 g | |
| Open, Shock Direction: B1 5 g | |
| Resistance to Vibrations | 3g Closed Position & 3g Open Position 5 ... 300 Hz |
| Pollution Degree | 3 |
| Material Compliance | |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| REACH Declaration | 2CMT2021-006202 |
| RoHS Declaration | 2CMT2021-006277 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| SCIP | 2d5965a6-5b05-4e83-9459-9b5d78318aa2 France |
| Simplified SCIP | 57ec6da0-6b74-4d41-942c-28c569726642 Poland |
| 5d3a40e2-0dd2-48f8-ae60-df6cfd6688b6 Belgium | |
| 84e38467-b47e-41a7-a633-0e291c7314f6 Hungary | |
| dacab1dc-889c-43ea-957a-0278e2eb9308 Bulgaria | |
| 9bd00c9e-233b-4130-8db2-5b4e46325892 Hungary | |
| 05d34ee2-b106-4e9e-8aaf-bb3c0696dab1 Belgium | |
| b8f41cb2-309c-4bca-b0f8-31c8411b3c2d Italy | |
| 73f32aa1-94bb-4e00-9ed0-49dd4c1836be Germany | |
| f43cd794-f0d3-407d-a0c2-2e1624bd39f8 Netherlands | |
| f6d0f85a-81dc-4d65-a3b8-a6c580818d49 Greece | |
| b5f1e100-759a-4cac-9740-c5ad3386a78c Finland | |
| 0bc3bb53-fcd8-496e-bf2c-4988d9b5f9e5 Sweden | |
| 98c08dc1-2723-4141-a883-43d88a9c1f8e Poland | |
| 4186d146-0fba-45da-a4c2-c87d50cbf7f1 Germany | |
| 3115cc1f-b1ba-44a5-a504-88ff86c3be36 Spain | |
| cbacee52-8d3e-4f4d-b9c8-53847a4f9923 Sweden | |
| e2e8ca03-6811-4164-a875-294c3d170711 Norway | |
| 64bf0ced-9457-40a7-8fb3-ad748bb21388 Croatia | |
| f12fcaa6-7e48-48c3-8dae-bce6dc6370f1 Portugal | |
| ba370118-f149-4c18-a5b4-98ddd3a0e2ee Germany | |
| 72f40100-060e-4ff9-b571-06ff58ce4bfe Denmark | |
| 32d40bf1-bae3-4434-bfe4-6d33f50f23d0 Germany | |
| 4d8bf81b-1918-4230-bc72-81d884b83cc7 Czech Republic | |
| 5061ae4c-ad66-4a1a-8bea-d068495ba286 Poland | |
| c60693b3-55d4-45d9-a28b-032cb87a11b0 Estonia | |
| 0b815038-d3f8-47af-b03c-1494f6049fce Germany | |
| 87ca08be-a7de-4803-890e-63cdc6854bbf France | |
| Toxic Substances Control Act - TSCA | 2CMT2023-006525 |
| WEEE B2C / B2B | Business To Business |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| ABB EcoSolutions | |
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | No non-hazardous waste is sent to a landfill |
| End Of Life Disassembling Instructions | 1SBC101081M6801 |
| Environmental Product Declaration - EPD | 1SBD250584E2000 |
| Improved Energy Efficiency for Customers | Product Efficiency - Product considered more energy-efficient compared to similar product on market or older products from the same line |
| Product Efficiency - Product requires less energy to operate compared to similar product on market or older products from the same line | |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 91.9 % |
| Certificates and Declarations | |
| A2L Certificate – UL | 9AKK108469A4890 |
| 9AKK108469A4892 | |
| ABS Certificate | ABS_20-2060694-PDA |
| BV Certificate | BV_2634H36994B2 |
| CB Certificate | CB_SE-116522 |
| CCC Certificate | CCC_2024010304656667 |
| Declaration of Conformity - CCC | 2020980304001255 |
| Declaration of Conformity - CE | 1SBD250000U1000 |
| Declaration of Conformity - UKCA | 1SBD250031U1000 |
| DNV Certificate | DNV_TAE00001AF-4 |
| KC Certificate | KC_HW02016-15011C |
| LR Certificate | LRS_LR23403517TA-02 |
| RINA Certificate | RINA_ELE084013XG |
| RMRS Certificate | RMRS_1802705280 |
| UL Certificate | UL-US-L312527-1141-10303102-19 |
| UL-CA-L312527-4141-10303102-19 | |
| UL Listing Card | UL_E312527 |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 150 mm |
| Package Level 1 Depth / Length | 150 mm |
| Package Level 1 Height | 103 mm |
| Package Level 1 Gross Weight | 1.29 kg |
| Package Level 1 EAN | 3471523132931 |
| Package Level 2 Units | box 8 piece |
| Package Level 2 Width | 250 mm |
| Package Level 2 Depth / Length | 300 mm |
| Package Level 2 Height | 300 mm |
| Package Level 2 Gross Weight | 10.32 kg |
| External Classifications and Standards | |
| Object Classification Code | Q |
| ETIM 7 | EC000066 - Power contactor, AC switching |
| ETIM 8 | EC000066 - Power contactor, AC switching |
| ETIM 9 | EC000066 - Power contactor, AC switching |
| eClass | V11.0 : 27371003 |
| UNSPSC | 39121529 |
| IDEA Granular Category Code (IGCC) | 4758 >> Iec Contactors |
| E-Number (Finland) | 3707122 |
| E-Number (Sweden) | 3210053 |
| Feature Name | Feature Value |
|---|---|
| Rated control supply voltage AC 50 Hz (EF003978) | 100 V |
| Rated control supply voltage AC 60 Hz (EF003979) | 100 V |
| Rated control supply voltage DC (EF003980) | 100 V |
| Voltage type for actuating (EF008242) | AC/DC |
| Rated operation current Ie at AC-1, 400 V (EF001393) | 125 A |
| Rated operation current Ie at AC-3, 400 V (EF001392) | 80 A |
| Rated operation power at AC-3, 400 V (EF001364) | 37 kW |
| Rated operation power NEMA (EF011960) | 37.2850 kW |
| Modular version (EF001126) | No |
| Number of auxiliary contacts as normally open contact (EF001376) | 0 |
| Number of auxiliary contacts as normally closed contact (EF001377) | 0 |
| Type of electrical connection of main circuit (EF006819) | Screw connection |
| Number of normally closed contacts as main contact (EF001375) | 0 |
| Number of normally open contacts as main contact (EF001374) | 3 |
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOGUE MOTOR PROTECTION EN.pdf | 240 Mbytes |
|
| AF80-30-00-13 100-250V50/60HZ-DC Contactor - ABB - AF80-30-00-13 - 1SBL397001R1300 | 99 Kbytes |
![]() |
| AF80-30-00-13 1SBL397001R1300 ABB AF80-30-00-13 100-250V50/60HZ-DC Contactor | 80 Kbytes |
![]() |
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.