A95-30-11 1SFL431001R8011 ABB 220-230V 50Hz / 230-240V 60Hz Contactor View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

A95-30-11 1SFL431001R8011 ABB 220-230V 50Hz / 230-240V 60Hz Contactor

A95-30-11

1SFL431001R8011

ABB

220-230V 50Hz / 230-240V 60Hz Contactor

More details


Service Breakers

* Brand new product in its original packaging covered by the warranties and certifications provided by ABB

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



Ordering

Minimum Order Quantity: 1 piece
Customs Tariff Number: 85364900
Replacement Product ID (NEW): 1SBL407001R1311

Popular Downloads

Data Sheet, Technical Information: 1SBC100192C0206
Instructions and Manuals: 5309660-60
Dimension Diagram: 53540923-1

Dimensions

Product Net Width: 102 mm
Product Net Depth / Length: 123.5 mm
Product Net Height: 148 mm
Product Net Weight: 2.04 kg

Technical

Number of Main Contacts NO: 3
Number of Main Contacts NC: 0
Number of Auxiliary Contacts NO: 1
Number of Auxiliary Contacts NC: 1
Rated Operational Voltage: Main Circuit 1000 V
Rated Frequency (f): Main Circuit 50/60 Hz
Conventional Free-air Thermal Current (Ith): acc. to IEC 60947-4-1, Open Contactors q = 40 °C 145 A
Rated Operational Current AC-1 (Ie): (690 V) 55 °C 135 A
(690 V) 40 °C 145 A
(690 V) 70 °C 115 A
Rated Operational Current AC-3 (Ie): (1000 V) 55 °C 30 A
(415 V) 55 °C 96 A
(690 V) 55 °C 65 A
(220 / 230 / 240 V) 55 °C 96 A
(440 V) 55 °C 93 A
(380 / 400 V) 55 °C 96 A
(500 V) 55 °C 80 A
Rated Operational Power AC-3 (Pe): (500 V) 55 kW
(1000 V) 40 kW
(690 V) 55 kW
(220 / 230 / 240 V) 25 kW
(380 / 400 V) 45 kW
(440 V) 55 kW
(415 V) 55 kW
Rated Breaking Capacity AC-3 acc. to IEC 60947-4-1: 8 x Ie AC-3
Rated Making Capacity AC-3 acc. to IEC 60947-4-1: 10 x Ie AC-3
Short-Circuit Protective Devices: gG Type Fuses 160 A
Rated Short-time Withstand Current (Icw): at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 500 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 160 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 800 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1320 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 350 A
Maximum Breaking Capacity: cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1160 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 800 A
Maximum Electrical Switching Frequency: AC-3 300 cycles per hour
AC-1 300 cycles per hour
AC-2 / AC-4 150 cycles per hour
Rated Operational Current DC-1 (Ie): (110 V) 2 Poles in Series, 40 °C 145 A
(220 V) 3 Poles in Series, 40 °C 145 A
Rated Operational Current DC-3 (Ie): (110 V) 2 Poles in Series, 40 °C 145 A
(220 V) 3 Poles in Series, 40 °C 145 A
Rated Operational Current DC-5 (Ie): (110 V) 2 Poles in Series, 40 °C 145 A
(220 V) 3 Poles in Series, 40 °C 145 A
Rated Insulation Voltage (Ui): acc. to UL/CSA 600 V
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
Rated Impulse Withstand Voltage (Uimp): Main Circuit 8 kV
Mechanical Durability: 10 million
Maximum Mechanical Switching Frequency: 3600 cycles per hour
Coil Operating Limits: (acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C) °C
Rated Control Circuit Voltage (Uc): 60 Hz 230 ... 240 V
50 Hz 220 ... 230 V
Coil Consumption: Pull-in at Max. Rated Control Circuit Voltage 60 Hz 450 V·A
Holding at Max. Rated Control Circuit Voltage 50 Hz 22 V·A
Pull-in at Max. Rated Control Circuit Voltage 50 Hz 350 V·A
Holding at Max. Rated Control Circuit Voltage 60 Hz 26 V·A
Operate Time: Between Coil Energization and NO Contact Closing 10 ... 25 ms
Between Coil De-energization and NO Contact Opening 10 ... 18 ms
Between Coil De-energization and NC Contact Closing 7 ... 15 ms
Between Coil Energization and NC Contact Opening 7 ... 22 ms
Connecting Capacity Main Circuit: Flexible with Cable End 2 x 6 ... 35 mm²
Bar 30 mm²
Rigid 1 x 10 ... 95 mm²
Connecting Capacity Auxiliary Circuit: Solid 2 x 1 ... 4 mm²
Flexible with Insulated Ferrule 2 x 0.75 ... 2.5 mm²
Stranded 2 x 1 .... 4 mm²
Flexible 2x0.75 ... 2.5 mm²
Flexible with Ferrule 2 x 0.75 ... 2.5 mm²
Degree of Protection: acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Connecting terminals (delivered in open position) Main poles: M8 hexagon socket screw with single connector
Terminal Type: Cable Clamp

Environmental

Ambient Air Temperature: Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... +50 °C
Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... +70 °C
Close to Contactor for Storage -60 ... +80 °C
Maximum Operating Altitude Permissible: 3000 m
Resistance to Shock acc. to IEC 60068-2-27: Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: A 20 g
Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: C2 20 g
Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: A 20 g
Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: B1 15 g
Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: C1 20 g
Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: B2 15 g
Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: C2 20 g
Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: B1 5 g
Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: C1 20 g
RoHS Status: Following EU Directive 2011/65/EU

Technical UL/CSA

Maximum Operating Voltage UL/CSA: Main Circuit 600 V
General Use Rating UL/CSA: (600 V AC) 125 A
Horsepower Rating UL/CSA: (208 V AC) Three Phase 30 Hp
(440 ... 480 V AC) Three Phase 60 Hp
(550 ... 600 V AC) Three Phase 75 Hp
(220 ... 240 V AC) Three Phase 30 Hp
(200 V AC) Three Phase 30 Hp

Certificates and Declarations (Document Number)

BV Certificate: 07172/D0 BV
CB Certificate: SE-69430
CCC Certificate: CQC_2002010304008904
Declaration of Conformity - CE: 2CMT2015-005436
DNV Certificate: DNV_E-12191
Environmental Information: 1SFC101001D0201
GL Certificate: GL_99358-97HH
Instructions and Manuals: 5309660-60
LOVAG Certificate: SE-9645071-1
LR Certificate: LR_12-70027-E1
RINA Certificate: ELE060313XG/001
RMRS Certificate: RMRS_12-03683-315
RoHS Information: 2CMT2016-006207

Container Information

Package Level 1 Units: box 1 piece
Package Level 1 Width: 140 mm
Package Level 1 Depth / Length: 140 mm
Package Level 1 Height: 170 mm
Package Level 1 Gross Weight: 2 kg
Package Level 1 EAN: 7320500142776

Classifications

Object Classification Code: Q
ETIM 4: EC000066 - Magnet contactor, AC-switching
ETIM 5: EC000066 - Magnet contactor, AC-switching
ETIM 6: EC000066 - Power contactor, AC switching
ETIM 7: EC000066 - Power contactor, AC switching
UNSPSC: 39121529
E-Number (Norway): 3229999
E-Number (Sweden): 3229999

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.