A95-30-11
1SFL431001R8011
ABB
1
220-230V 50Hz / 230-240V 60Hz Contactor
Service Breakers
* Brand new product in its original packaging covered by the warranties and certifications provided by ABB
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
Minimum Order Quantity: | 1 piece |
Customs Tariff Number: | 85364900 |
Replacement Product ID (NEW): | 1SBL407001R1311 |
Data Sheet, Technical Information: | 1SBC100192C0206 |
Instructions and Manuals: | 5309660-60 |
Dimension Diagram: | 53540923-1 |
Product Net Width: | 102 mm |
Product Net Depth / Length: | 123.5 mm |
Product Net Height: | 148 mm |
Product Net Weight: | 2.04 kg |
Number of Main Contacts NO: | 3 |
Number of Main Contacts NC: | 0 |
Number of Auxiliary Contacts NO: | 1 |
Number of Auxiliary Contacts NC: | 1 |
Rated Operational Voltage: | Main Circuit 1000 V |
Rated Frequency (f): | Main Circuit 50/60 Hz |
Conventional Free-air Thermal Current (Ith): | acc. to IEC 60947-4-1, Open Contactors q = 40 °C 145 A |
Rated Operational Current AC-1 (Ie): | (690 V) 55 °C 135 A (690 V) 40 °C 145 A (690 V) 70 °C 115 A |
Rated Operational Current AC-3 (Ie): | (1000 V) 55 °C 30 A (415 V) 55 °C 96 A (690 V) 55 °C 65 A (220 / 230 / 240 V) 55 °C 96 A (440 V) 55 °C 93 A (380 / 400 V) 55 °C 96 A (500 V) 55 °C 80 A |
Rated Operational Power AC-3 (Pe): | (500 V) 55 kW (1000 V) 40 kW (690 V) 55 kW (220 / 230 / 240 V) 25 kW (380 / 400 V) 45 kW (440 V) 55 kW (415 V) 55 kW |
Rated Breaking Capacity AC-3 acc. to IEC 60947-4-1: | 8 x Ie AC-3 |
Rated Making Capacity AC-3 acc. to IEC 60947-4-1: | 10 x Ie AC-3 |
Short-Circuit Protective Devices: | gG Type Fuses 160 A |
Rated Short-time Withstand Current (Icw): | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 500 A at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 160 A at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 800 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1320 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 350 A |
Maximum Breaking Capacity: | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1160 A cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 800 A |
Maximum Electrical Switching Frequency: | AC-3 300 cycles per hour AC-1 300 cycles per hour AC-2 / AC-4 150 cycles per hour |
Rated Operational Current DC-1 (Ie): | (110 V) 2 Poles in Series, 40 °C 145 A (220 V) 3 Poles in Series, 40 °C 145 A |
Rated Operational Current DC-3 (Ie): | (110 V) 2 Poles in Series, 40 °C 145 A (220 V) 3 Poles in Series, 40 °C 145 A |
Rated Operational Current DC-5 (Ie): | (110 V) 2 Poles in Series, 40 °C 145 A (220 V) 3 Poles in Series, 40 °C 145 A |
Rated Insulation Voltage (Ui): | acc. to UL/CSA 600 V acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V |
Rated Impulse Withstand Voltage (Uimp): | Main Circuit 8 kV |
Mechanical Durability: | 10 million |
Maximum Mechanical Switching Frequency: | 3600 cycles per hour |
Coil Operating Limits: | (acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C) °C |
Rated Control Circuit Voltage (Uc): | 60 Hz 230 ... 240 V 50 Hz 220 ... 230 V |
Coil Consumption: | Pull-in at Max. Rated Control Circuit Voltage 60 Hz 450 V·A Holding at Max. Rated Control Circuit Voltage 50 Hz 22 V·A Pull-in at Max. Rated Control Circuit Voltage 50 Hz 350 V·A Holding at Max. Rated Control Circuit Voltage 60 Hz 26 V·A |
Operate Time: | Between Coil Energization and NO Contact Closing 10 ... 25 ms Between Coil De-energization and NO Contact Opening 10 ... 18 ms Between Coil De-energization and NC Contact Closing 7 ... 15 ms Between Coil Energization and NC Contact Opening 7 ... 22 ms |
Connecting Capacity Main Circuit: | Flexible with Cable End 2 x 6 ... 35 mm² Bar 30 mm² Rigid 1 x 10 ... 95 mm² |
Connecting Capacity Auxiliary Circuit: | Solid 2 x 1 ... 4 mm² Flexible with Insulated Ferrule 2 x 0.75 ... 2.5 mm² Stranded 2 x 1 .... 4 mm² Flexible 2x0.75 ... 2.5 mm² Flexible with Ferrule 2 x 0.75 ... 2.5 mm² |
Degree of Protection: | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10 |
Connecting terminals (delivered in open position) Main poles: | M8 hexagon socket screw with single connector |
Terminal Type: | Cable Clamp |
Ambient Air Temperature: | Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... +50 °C Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... +70 °C Close to Contactor for Storage -60 ... +80 °C |
Maximum Operating Altitude Permissible: | 3000 m |
Resistance to Shock acc. to IEC 60068-2-27: | Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: A 20 g Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: C2 20 g Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: A 20 g Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: B1 15 g Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: C1 20 g Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: B2 15 g Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: C2 20 g Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: B1 5 g Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: C1 20 g |
RoHS Status: | Following EU Directive 2011/65/EU |
Maximum Operating Voltage UL/CSA: | Main Circuit 600 V |
General Use Rating UL/CSA: | (600 V AC) 125 A |
Horsepower Rating UL/CSA: | (208 V AC) Three Phase 30 Hp (440 ... 480 V AC) Three Phase 60 Hp (550 ... 600 V AC) Three Phase 75 Hp (220 ... 240 V AC) Three Phase 30 Hp (200 V AC) Three Phase 30 Hp |
BV Certificate: | 07172/D0 BV |
CB Certificate: | SE-69430 |
CCC Certificate: | CQC_2002010304008904 |
Declaration of Conformity - CE: | 2CMT2015-005436 |
DNV Certificate: | DNV_E-12191 |
Environmental Information: | 1SFC101001D0201 |
GL Certificate: | GL_99358-97HH |
Instructions and Manuals: | 5309660-60 |
LOVAG Certificate: | SE-9645071-1 |
LR Certificate: | LR_12-70027-E1 |
RINA Certificate: | ELE060313XG/001 |
RMRS Certificate: | RMRS_12-03683-315 |
RoHS Information: | 2CMT2016-006207 |
Package Level 1 Units: | box 1 piece |
Package Level 1 Width: | 140 mm |
Package Level 1 Depth / Length: | 140 mm |
Package Level 1 Height: | 170 mm |
Package Level 1 Gross Weight: | 2 kg |
Package Level 1 EAN: | 7320500142776 |
Object Classification Code: | Q |
ETIM 4: | EC000066 - Magnet contactor, AC-switching |
ETIM 5: | EC000066 - Magnet contactor, AC-switching |
ETIM 6: | EC000066 - Power contactor, AC switching |
ETIM 7: | EC000066 - Power contactor, AC switching |
UNSPSC: | 39121529 |
E-Number (Norway): | 3229999 |
E-Number (Sweden): | 3229999 |
Title: | Size: | Type: |
---|---|---|
A95-30-11 1SFL431001R8011 1SFL431001R8011_A95-30-11-80.pdf | 225 Kbytes |
No customer reviews for the moment.
Rating: | |
Name: | |
Email: | |
Subject: | |
Text: | |
Do you recommend this product to buy? | |
Add review |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.