A30-30-10 1SBL281001R8410 ABB 110V 50Hz / 110-120V 60Hz Contactor View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

A30-30-10 1SBL281001R8410 ABB 110V 50Hz / 110-120V 60Hz Contactor

A30-30-10

1SBL281001R8410

ABB

110V 50Hz / 110-120V 60Hz Contactor

More details


Service Breakers

Brand new product in its original packaging covered by the warranties and certifications provided by ABB

* This article may be obsolete.

Go to successor article: 1SBL271001R8400 1SBL271001R8400

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



Ordering

Minimum Order Quantity: 1 piece
Customs Tariff Number: 85364900

Popular Downloads

Data Sheet, Technical Information: 1SBC100122C0202_Ch02
Instructions and Manuals: FPTC407722P0001

Dimensions

Product Net Width: 54 mm
Product Net Depth / Length: 108.3 mm
Product Net Height: 90 mm
Product Net Weight: 0.71 kg

Technical

Number of Main Contacts NO: 3
Number of Main Contacts NC: 0
Number of Auxiliary Contacts NO: 1
Number of Auxiliary Contacts NC: 0
Standards: Devices complying with international standards IEC 947-1 / 947-4-1, and European standards EN 60 947-1 / 60 947-4-1. Electromagnetic compatibility (EMC) acc. to amendment A11 to IEC 947-1; EN 60 947-1 and amendment 2 to IEC 947-4-1
Rated Operational Voltage: Main Circuit 690 V
Rated Frequency (f): Supply Circuit 50 Hz
Supply Circuit 60 Hz
Conventional Free-air Thermal Current (Ith): acc. to IEC 60947-4-1, Open Contactors q = 40 °C 65 A
acc. to IEC 60947-5-1, q = 40 °C 16 A
Rated Operational Current AC-1 (Ie): (690 V) 40 °C 55 A
(690 V) 55 °C 55 A
(690 V) 70 °C 39 A
Rated Operational Current AC-3 (Ie): (220 / 230 / 240 V) 55 °C 33 A
(380 / 400 V) 55 °C 32 A
(415 V) 55 °C 32 A
(440 V) 55 °C 32 A
(500 V) 55 °C 28 A
(690 V) 55 °C 21 A
Rated Operational Power AC-3 (Pe): (220 / 230 / 240 V) 9 kW
(380 / 400 V) 15 kW
(415 V) 15 kW
(440 V) 18.5 kW
(500 V) 18.5 kW
(690 V) 18.5 kW
Rated Breaking Capacity AC-3 acc. to IEC 60947-4-1: 8 x Ie AC-3
Rated Making Capacity AC-3 acc. to IEC 60947-4-1: 10 x Ie AC-3
Rated Operational Current AC-15 (Ie): (220 / 240 V) 4 A
(24 / 127 V) 6 A
(380 / 440 V) 3 A
(500 V) 2 A
(690 V) 2 A
Short-Circuit Protective Devices: Auxiliary Circuit - gG Type Fuses 10 A
gG Type Fuses 63 A
Maximum Breaking Capacity: cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 820 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 340 A
Maximum Electrical Switching Frequency: AC-1 600 cycles per hour
AC-2 / AC-4 300 cycles per hour
AC-3 1200 cycles per hour
Rated Operational Current DC-13 (Ie): (125 V) 1.1 / 138 A
(24 V) 6 / 144 A
(250 V) 0.55 / 138 A
(48 V) 2.8 / 134 A
(72 V) 2 / 144 A
Rated Insulation Voltage (Ui): acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp): 8 kV
Maximum Mechanical Switching Frequency: 3600 cycles per hour
Rated Control Circuit Voltage (Uc): 50 Hz 110 V
60 Hz 110 ... 120 V
Coil Consumption: Average Holding Value 50 / 60 Hz 12 V·A
Average Holding Value 50 / 60 Hz 3 W
Average Pull-in Value 50 Hz 125 V·A
Average Pull-in Value 60 Hz 120 V·A
Operate Time: Between Coil Energization and NO Contact Closing 8 ... 21 ms
Between Coil De-energization and NO Contact Opening 4 ... 11 ms
Connecting Capacity Main Circuit: Flexible with Cable End 2.5 ... 10 mm²
Rigid Cable 2.5 ... 16 mm²
Connecting Capacity Auxiliary Circuit: Flexible with Cable End 0.75 ... 2.5 mm²
Rigid Cable 1 ... 4 mm²
Degree of Protection: acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
Connecting terminals (delivered in open position) Main poles: M 5 (+,-) pozidriv 2 screw with 2x (5.6x6.5 mm) connector
Terminal Type: Screw Terminals

Environmental

Ambient Air Temperature: Close to Contactor Fitted with Thermal O/L Relay -25 ... +55 °C
Close to Contactor for Storage -60 ... +80 °C
Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... +55 °C
Close to Contactor without Thermal O/L Relay (Uc) -40 ... +70 °C
Climatic Withstand: acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
Maximum Operating Altitude Permissible: 3000 m
Resistance to Shock acc. to IEC 60068-2-27: Shock Direction: A 20 g
Closed, Shock Direction: B1 10 g
Open, Shock Direction: B1 5 g
Shock Direction: B2 15 g
Shock Direction: C1 20 g
Shock Direction: C2 20 g
RoHS Status: Following EU Directive 2002/95/EC August 18, 2005 and amendment

Certificates and Declarations (Document Number)

BV Certificate: BV_2634H07559D0
CB Certificate: CB_FR_602227A
CCC Certificate: CCC_2013010304615752
CCC_2004010309133982
CSA Certificate: CSA_1033838_LR056745
Declaration of Conformity - CE: 1SBD250801U1000
DNV Certificate: DNV-GL_TAE00000TX
DNV GL Certificate: DNV-GL_TAE00000TX
EAC Certificate: EAC_RU C-FR ME77 B01010
Environmental Information: 1SBD250005E1002
GOST Certificate: GOST_POCCFRME77B07175
Instructions and Manuals: FPTC407722P0001
LOVAG Certificate: LOVAG_FR97008
LR Certificate: LRS_9830011E4
RINA Certificate: RINA_ELE128713XG001
RMRS Certificate: RMRS_0507015250
RoHS Information: 1SBD350054R1000
UL Certificate: UL_071301E39231

Container Information

Package Level 1 Units: 1 piece
Package Level 1 Width: 101 mm
Package Level 1 Depth / Length: 115 mm
Package Level 1 Height: 61 mm
Package Level 1 Gross Weight: 0.71 kg
Package Level 1 EAN: 3471522071842
Package Level 2 Units: 63 piece
Package Level 2 Gross Weight: 44.73 kg
Package Level 3 Units: 576 piece

Classifications

Object Classification Code: Q
ETIM 4: EC000066 - Magnet contactor, AC-switching
ETIM 5: EC000066 - Magnet contactor, AC-switching
ETIM 6: EC000066 - Power contactor, AC switching
ETIM 7: EC000066 - Power contactor, AC switching
UNSPSC: 39121529

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.