Product successfully added to your shopping cart
1SDA100856R1
ABB
1
XT7S 1250 Ekip Hi-Touch LSI 1250A 3p FF
Low-voltage industrial components > Power circuit-breaker for trafo/generator/installation protection
Molded case "Isomax-Tmax"
Brand new product in its original packaging covered by the warranties and certifications provided by ABB
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2357 |
| Environmental Product Declaration - EPD | 9AKK108468A1895 |
| 9AKK108468A4404 | |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 64.1 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 8f63f201-d71a-487f-b41d-b4bd99a6dc4e Italy |
| Simplified SCIP | fe4ee3f2-25c0-415b-a6b5-3f5cb0d3008f Greece |
| 605e7a64-d87d-44bc-8883-acd28a1a4c00 Portugal | |
| 605e7a64-d87d-44bc-8883-acd28a1a4c00 Portugal | |
| 2c25da82-19d8-4128-8da6-e4ee93e79730 Hungary | |
| 5c8c5d1a-7a89-460c-8d5f-15aa97ba635d Estonia | |
| 01a8298e-e0f9-45f3-bbcc-f767cf6181bb Hungary | |
| 5a7e7cd7-1d4e-478b-bcb3-a08afe565a03 Sweden | |
| bb3008f9-9090-46a7-9769-89d494325d88 Germany | |
| cd6c115b-effa-4866-a4e3-b2b506117e2f France | |
| 1aa90c71-d4ad-4628-a691-3d114afd99b7 Poland | |
| 2c25da82-19d8-4128-8da6-e4ee93e79730 Hungary | |
| 5c8c5d1a-7a89-460c-8d5f-15aa97ba635d Estonia | |
| b4dac7d4-9733-4e40-90dd-314aec3813fa France | |
| 0fdb534e-ccae-4120-9dfe-bdb19e44e9fb Poland | |
| 77a05f4f-b312-4666-888d-ed4eaf9f8c55 Belgium | |
| 44ae7733-f9e2-4fbe-8180-5a0ce3572357 Finland | |
| 26218c1a-ff55-4ada-8c3e-cf37739e1caa Germany | |
| ce0e1d97-676e-4741-b451-29e16384bdff Sweden | |
| 11c6d039-64d5-4219-ac21-d15d6b178a7c Germany | |
| ca17959d-7297-4087-9065-4110e76bd48c Czech Republic | |
| cd6c115b-effa-4866-a4e3-b2b506117e2f France | |
| 44eedd7d-8e15-419b-a3bf-bc52ce2cc8b1 Norway | |
| fe4ee3f2-25c0-415b-a6b5-3f5cb0d3008f Greece | |
| fc3cafd2-53d7-4eb5-a8a5-764716ca36fa Croatia | |
| 52e05cd8-bd45-4647-b962-2d177ebd2915 Poland | |
| 0a615c08-9541-412e-ac45-5fba78bfb9bf Denmark | |
| 1aa90c71-d4ad-4628-a691-3d114afd99b7 Poland | |
| 3b21f073-ea5e-4551-b7fe-8fb11705b741 Germany | |
| bb3008f9-9090-46a7-9769-89d494325d88 Germany | |
| 5a7e7cd7-1d4e-478b-bcb3-a08afe565a03 Sweden | |
| db99fd4d-b28a-468a-8149-7496ae5626e1 Netherlands | |
| 26218c1a-ff55-4ada-8c3e-cf37739e1caa Germany | |
| 0fdb534e-ccae-4120-9dfe-bdb19e44e9fb Poland | |
| 11c6d039-64d5-4219-ac21-d15d6b178a7c Germany | |
| b3f0a0cd-f946-43df-aad3-6bd40de977a6 Belgium | |
| ce0e1d97-676e-4741-b451-29e16384bdff Sweden | |
| b4dac7d4-9733-4e40-90dd-314aec3813fa France | |
| 3b21f073-ea5e-4551-b7fe-8fb11705b741 Germany | |
| b74fbb60-a586-4be4-9b7e-de04e8897995 Spain | |
| 01a8298e-e0f9-45f3-bbcc-f767cf6181bb Hungary | |
| 77a05f4f-b312-4666-888d-ed4eaf9f8c55 Belgium | |
| b3f0a0cd-f946-43df-aad3-6bd40de977a6 Belgium | |
| 52e05cd8-bd45-4647-b962-2d177ebd2915 Poland | |
| b74fbb60-a586-4be4-9b7e-de04e8897995 Spain | |
| 44ae7733-f9e2-4fbe-8180-5a0ce3572357 Finland | |
| 44eedd7d-8e15-419b-a3bf-bc52ce2cc8b1 Norway | |
| 98d4e6e8-ebeb-4289-b178-3d5ac1792889 Germany | |
| 63d7985d-184f-4238-8e59-5899fc170089 Bulgaria | |
| 0a615c08-9541-412e-ac45-5fba78bfb9bf Denmark | |
| 98d4e6e8-ebeb-4289-b178-3d5ac1792889 Germany | |
| db99fd4d-b28a-468a-8149-7496ae5626e1 Netherlands | |
| ca17959d-7297-4087-9065-4110e76bd48c Czech Republic | |
| 63d7985d-184f-4238-8e59-5899fc170089 Bulgaria | |
| fc3cafd2-53d7-4eb5-a8a5-764716ca36fa Croatia | |
| Environmental | |
| Ambient Air Temperature | Operation -40 ... 125 °C |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | XT7SE312ETFF000XXX |
| E-Number (Norway) | 4380641 |
| EAN | 8056221009102 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 210 mm |
| Product Net Height | 268 mm |
| Product Net Depth / Length | 166 mm |
| Product Net Weight | 9.7 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 280 mm |
| Package Level 1 Height | 350 mm |
| Package Level 1 Depth / Length | 360 mm |
| Package Level 1 Gross Weight | 11.2 kg |
| Package Level 1 EAN | 8056221009102 |
| Additional Information | |
| Circuit Breaker Type to be Associated | Power Distribution |
| Product Main Type | SACE Tmax XT |
| Product Name | Moulded Case Circuit Breaker |
| Product Type | Automatic Circuit Breaker |
| Version | F |
| CAD Dimensional Drawing | 1SDH002065A1336 |
| 1SDH002065A1338 | |
| Technical | |
| Current Type | AC |
| Electrical Durability | 3000 cycle |
| 60 cycles per hour | |
| Mechanical Durability | 10000 cycle |
| 60 cycles per hour | |
| Number of Poles | 3P |
| Order Multiple | 1 piece |
| Power Loss | at Rated Operating Conditions per Pole 57 W |
| Rated Current (In) | 1250 A |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Rated Insulation Voltage (Ui) | 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 85 kA |
| (230 V AC) 85 kA | |
| (240 V AC) 85 kA | |
| (380 V AC) 50 kA | |
| (415 V AC) 50 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 45 kA | |
| (525 V AC) 45 kA | |
| (690 V AC) 30 kA | |
| Rated Short-time Withstand Current Low Voltage (Icw) | 20 kA |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 85 kA |
| (230 V AC) 85 kA | |
| (240 V AC) 85 kA | |
| (380 V AC) 50 kA | |
| (415 V AC) 50 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 45 kA | |
| (525 V AC) 45 kA | |
| (690 V AC) 30 kA | |
| Rated Uninterrupted Current (Iu) | 1250 A |
| Release | Ekip Hi-Touch LSI |
| Release Type | EL |
| Short-Circuit Performance Level | S |
| Standards | IEC60947-2 |
| Sub-type | XT7 |
| Terminal Connection Type | Front |
| Certificates and Declarations | |
| Data Sheet, Technical Information | 1SDC210100D0206 |
| 1SDC210099D0206 | |
| Declaration of Conformity - CE | 9AKK107046A9648 |
| Mechanical Drawings | 1SDH002013A1101 |
| Wiring Diagram | 1SDM000002A1001 |
| Instructions and Manuals | 1SDH002013A1001 |
| 1SDH002013A1002 | |
| 1SDH001821A1001 | |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| Object Classification Code | Q |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |
| Feature Name | Feature Value |
|---|---|
| Rated permanent current Iu (EF001389) | 1250 A |
| Rated voltage (EF003977) | 690 V |
| Overload release current setting (EF002336) | 1250 A |
| Adjustment range short-term delayed short-circuit release (EF007129) | 12500 A |
| Adjustment range undelayed short-circuit release (EF007131) | 1875.0 A |
| Integrated earth fault protection (EF007296) | No |
| Type of electrical connection of main circuit (EF006819) | Bolt connection |
| Device construction (EF008240) | Built-in device fixed built-in technique |
| Suitable for DIN rail (top hat rail) mounting (EF007250) | No |
| DIN rail (top hat rail) mounting optional (EF008904) | No |
| Number of auxiliary contacts as normally closed contact (EF001377) | 0 |
| Number of auxiliary contacts as normally open contact (EF001376) | 0 |
| Number of auxiliary contacts as change-over contact (EF003531) | 0 |
| With switched-off indicator (EF007006) | No |
| With integrated under voltage release (EF001390) | No |
| Number of poles (EF001391) | 3 |
| Position of connection for main current circuit (EF006671) | Front |
| Type of control element (EF006976) | Toggle |
| Complete device with protection unit (EF008906) | Yes |
| Motor drive integrated (EF006697) | No |
| Motor drive optional (EF007386) | Yes |
| Degree of protection (IP) (EF005474) | IP20 |
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOG ABB TMAX XT EN.pdf | 70 Mbytes |
|
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.