Product successfully added to your shopping cart
1SDA054347R1
ABB
1
T5S 400 PR222DS/P-LSIG In=400 4p F F
Molded case "Isomax-Tmax"
Brand new product in its original packaging covered by the warranties and certifications provided by ABB
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| ABB EcoSolutions | |
|---|---|
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 4d594122-13a4-4720-b6f3-9147c972ae89 China |
| Simplified SCIP | 990a9134-1b45-4971-b9ef-7f9519ca699f Finland |
| 4cb6c4c4-a428-487a-b0fb-5f88b959629b Belgium | |
| 9868e7c9-d567-4342-886a-53b915b6098e Estonia | |
| c0eeea4c-c9d2-4635-b124-fa1c75059586 Netherlands | |
| 6cf7ac4f-23bc-4aed-b682-041c2388db1d Poland | |
| e9a5a742-835d-43f8-bfee-b5ff527c8898 Hungary | |
| f6047d0e-2d59-4dbf-b1da-bc858c5c8cdc Denmark | |
| 4d4c07db-2bf1-4aca-ad30-56d6f96e8d53 Germany | |
| 81ae0466-e821-4410-9534-d7eeddb2a807 Germany | |
| b352bf92-137c-4f0c-bbc9-63b7977cb33f Germany | |
| c4c671d3-f766-4d37-bfe4-b1efffffc901 France | |
| 03e82293-1d01-41e6-b70f-f19213aba2ee Bulgaria | |
| dec077aa-6856-4557-b593-f0b135f55389 Portugal | |
| 251bcf48-e413-4841-8807-2e315ad75b14 Greece | |
| 880f83e8-94cb-4646-a1c3-2b5b03391c41 Sweden | |
| cb305ad7-2ce2-4f6e-be47-9b8e71c083be Poland | |
| c8d4e866-7fbc-46b1-89d1-66411719143f Belgium | |
| a286b4f5-1270-49a6-80a3-cdcae96e4ef6 Germany | |
| 45113b76-b1a6-4976-874b-ab466b753a95 Spain | |
| e7cf5975-9e36-493f-a345-a44ba82ee7db France | |
| 240195b4-6c8a-470b-bf43-0aa60f559db9 Sweden | |
| 53041b0b-1cfe-4cf6-955b-d0c19c4c8c76 Poland | |
| 9d53f236-70a0-4ebd-9222-2d729dc16f3a Croatia | |
| 3864c5fb-b235-485d-8575-5e6ea4a5cdc2 Germany | |
| f2252830-41ff-4ad7-a258-d28d1d7d3823 Norway | |
| 3adf1bc4-845b-47a9-8cc1-7489cbfefce0 Czech Republic | |
| 621cbe36-afd7-47ce-a037-18b8cccb82c1 Hungary | |
| Environmental | |
| Environmental Information | 9AKK10103A1056 |
| 9AKK108467A6707 | |
| Ordering | |
| E-Number (Finland) | 3655400 |
| E-Number (Norway) | 4384067 |
| EAN | 8015644554453 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 186 mm |
| Product Net Height | 205 mm |
| Product Net Depth / Length | 103.5 mm |
| Product Net Weight | 6.2 kg |
| Container Information | |
| Package Level 1 Units | 1 piece |
| Package Level 1 Width | 248 mm |
| Package Level 1 Height | 240 mm |
| Package Level 1 Depth / Length | 285 mm |
| Package Level 1 Gross Weight | 6.2 kg |
| Package Level 1 EAN | 8015644554453 |
| Additional Information | |
| Product Main Type | SACE Tmax T |
| Product Name | Moulded Case Circuit Breaker |
| Product Type | Automatic Circuit Breaker |
| Suitable For | T5 |
| Suitable for Product Class | Moulded Case Circuit Breakers |
| Version | F |
| Technical | |
| Electrical Durability | 7000 cycle |
| 60 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 120 cycles per hour | |
| Number of Poles | 4P |
| Power Loss | at Rated Operating Conditions per Pole 16.5 W |
| Rated Current (In) | 400 A |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Rated Insulation Voltage (Ui) | 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 85 kA |
| (230 V AC) 85 kA | |
| (380 V AC) 50 kA | |
| (400 V AC) 50 kA | |
| (415 V AC) 50 kA | |
| (440 V AC) 40 kA | |
| (500 V AC) 30 kA | |
| (690 V AC) 25 kA | |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 5 kA |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 85 kA |
| (230 V AC) 85 kA | |
| (380 V AC) 50 kA | |
| (400 V AC) 50 kA | |
| (415 V AC) 50 kA | |
| (440 V AC) 40 kA | |
| (500 V AC) 30 kA | |
| (690 V AC) 25 kA | |
| Rated Uninterrupted Current (Iu) | 400 A |
| Release | PR222DS/P-LSIG |
| Release Type | EL |
| Short-Circuit Performance Level | S |
| Standards | IEC |
| Sub-type | T5 |
| Terminal Connection Type | Fixed Circuit-Breakers |
| Front | |
| Test Voltage Max (Utest) | 3500 V |
| Test Voltage at Industrial Frequency for 1 Minute | 3500 V |
| Certificates and Declarations | |
| Data Sheet, Technical Information | 1SDC210004D0203 |
| Declaration of Conformity - CE | 9AKK106713A5539 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| GL Certificate | 1SDL000163R0062 |
| Instructions and Manuals | 1SDH000437R0001 |
| Instructions and Manuals (Part 2) | ITSCE-RH0100001 |
| Instructions and Manuals (Part 3) | 1SDH000436R0502 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| Object Classification Code | Q |
| UNSPSC | 39121100 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOG ABB TMAX XT EN.pdf | 70 Mbytes |
|
| 1SDA054347R1 EN_1SDA054347R1.pdf | 93 Kbytes |
![]() |
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.