1SBH143001R8740 ABB Contactor NL40E 125 V DC View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

1SBH143001R8740 ABB Contactor NL40E 125 V DC

1SBH143001R8740

ABB

Contactor NL40E 125 V DC

NL40E 125 V DC Contactor Relay

More details


Service Breakers

* Brand new product in its original packaging covered by the warranties and certifications provided by ABB

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



  • Extended Product Type:
    NL40E 125 V DC
  • Product ID:
    1SBH143001R8740
  • EAN:
    3471522294876
  • Catalog Description:
    NL40E 125 V DC Contactor Relay
  • Long Description:
    NL... contactor relays are used for switching auxiliary circuits and control circuits - Poles: 4-pole contactor relays (mechanically linked contact elements available) - Control circuit: DC operated with solid core magnet circuit. The polarity on the coil terminals (A1+ and A2-) must be respected - Accessories: a wide range of accessories is available NL... contactors are fitted with low consumption DC coils and are suitable for a direct control by PLC outputs.

Ordering

  • Minimum Order Quantity:
    1 piece
  • Customs Tariff Number:
    85364900

Popular Downloads

Dimensions

  • Product Net Width:
    44mm
  • Product Net Depth / Length:
    97mm
  • Product Net Height:
    78mm
  • Product Net Weight:
    0.52kg

Technical

  • Number of Auxiliary Contacts NO:
    4
  • Number of Auxiliary Contacts NC:
    0
  • Rated Operational Voltage:
    Auxiliary Circuit 690 V
  • Rated Frequency (f):
    Supply Circuit 50 / 60 Hz
  • Conventional Free-air Thermal Current (Ith):
    acc. to IEC 60947-5-1, q = 40 °C 16 A
  • Rated Operational Current AC-15 (Ie):
    (500 V) 2 A
    (690 V) 2 A
    (24 / 127 V) 6 A
    (220 / 240 V) 4 A
    (380 / 400 V) 3 A
  • Short-Circuit Protective Devices:
    Auxiliary Circuit - gG Type Fuses 10 A
  • Rated Short-time Withstand Current Low Voltage (Icw):
    for 0.1 s 140 A
    for 1 s 100 A
  • Maximum Electrical Switching Frequency:
    1200 cycles per hour
  • Rated Operational Current DC-13 (Ie):
    (24 V) 6 / 144 A
    (48 V) 2.8 / 134 A
    (72 V) 1 / 72 A
    (125 V) 0.55 / 69 A
    (250 V) 0.3 / 75 A
  • Rated Insulation Voltage (Ui):
    acc. to IEC 60947-5-1 and VDE 0110 (Gr. C) 690 V
    acc. to UL/CSA 600 V
  • Rated Impulse Withstand Voltage (Uimp):
    8 kV
  • Mechanical Durability:
    > 20 million
  • Maximum Mechanical Switching Frequency:
    6000 cycles per hour
  • Rated Control Circuit Voltage (Uc):
    DC Operation 125 V
  • Coil Consumption:
    Average Holding Value, from Warm State 3 W
    Average Pull-in Value, from Cold State 3 W
  • Operate Time:
    Between Coil De-energization and NO Contact Opening 10 ... 17 ms
    Between Coil Energization and NO Contact Closing 50 ... 100 ms
  • Mounting on DIN Rail:
    TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
    TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
  • Mounting by Screws (not supplied):
    2 x M4 screws placed diagonally
  • Connecting Capacity Auxiliary Circuit:
    Flexible with Cable End 0.75 ... 2.5 mm²
    Rigid Cable 1 ... 4 mm²
  • Degree of Protection:
    acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20
    acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
  • Terminal Type:
    Screw Terminals

Environmental

  • Ambient Air Temperature:
    Close to Contactor for Storage -60 ... +80 °C
    Near Contactor for Operation in Free Air (0.85 ... 1.1 Uc) -40 ... 55 °C
    Near Contactor for Operation in Free Air (Uc) -40 ... 70 °C
  • Climatic Withstand:
    acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
  • Maximum Operating Altitude Permissible:
    Without Derating 3000 m
  • Resistance to Shock acc. to IEC 60068-2-27:
    Closed, Shock Direction: A 20 g
    Closed, Shock Direction: B1 15 g
    Closed, Shock Direction: C1 20 g
    Closed, Shock Direction: C2 14 g
    Open, Shock Direction: A 10 g
    Open, Shock Direction: B1 5 g
    Open, Shock Direction: C1 8 g
    Open, Shock Direction: C2 8 g
    Shock Direction: B2 10 g
  • RoHS Status:
    Following EU Directive 2011/65/EU

Certificates and Declarations (Document Number)

Container Information

  • Package Level 1 Units:
    1 piece
  • Package Level 1 Width:
    86 mm
  • Package Level 1 Depth / Length:
    141 mm
  • Package Level 1 Height:
    51 mm
  • Package Level 1 Gross Weight:
    0.52 kg
  • Package Level 1 EAN:
    3471522294876
  • Package Level 2 Units:
    box 28 piece
  • Package Level 2 Width:
    300 mm
  • Package Level 2 Depth / Length:
    245 mm
  • Package Level 2 Height:
    308 mm
  • Package Level 2 Gross Weight:
    14.56 kg
  • Package Level 3 Units:
    336 piece

Classifications

  • Object Classification Code:
    K
  • ETIM 4:
    EC000196 - Contactor relay
  • ETIM 5:
    EC000196 - Contactor relay
  • ETIM 6:
    EC000196 - Contactor relay
  • ETIM 7:
    EC000196 - Contactor relay
  • eClass:
    V11.0 : 27371018
  • UNSPSC:
    39121500

Datasheet - PDF

Title: Size: Type:
1SBH143001R8740 EN_1SBH143001R8740.pdf 101 Kbytes     1SBH143001R8740 EN_1SBH143001R8740.pdf

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.