Produto adicionado com sucesso ao seu carrinho de compras
AXL BK PN
2688019
PHOENIX_CONTACT
1
Axioline acoplador de bus para PROFINET (incluindo a base de ônibus e ficha)
Home > PHOENIX_CONTACT
* Produto novo em sua embalagem original com todas as garantias e certificações de PHOENIX_CONTACT
Obrigado pelo seu interesse nos nossos artigos, esperamos que o prazo indicado seja conveniente para si.
Durante a preparação do pedido pode seleccionar o tipo de envío que melhor se adapte ás suas necessidades: Aéreo Express 24Hrs, Terrestre Standard 48/72Hrs, etc.
The bus coupler links a PROFINET network with the Axioline system.
Up to 63 Axioline devices can be connected at any point to an existing PROFINET system using the bus coupler.
For startup tests you can put the Axioline station into operation independent of the higher-level network either using the service interface or an Ethernet port at the bus coupler.
Width | 40 mm |
---|---|
Height | 123.6 mm |
Depth | 75 mm |
Note on dimensions | The depth is valid when a TH 35-7.5 DIN rail is used (according to EN 60715). |
Ambient temperature (operation) | -25 °C ... 60 °C |
---|---|
Ambient temperature (storage/transport) | -40 °C ... 85 °C |
Permissible humidity (operation) | 5 % ... 95 % (according to DIN EN 61131-2) |
Permissible humidity (storage/transport) | 5 % ... 95 % (according to DIN EN 61131-2) |
Air pressure (operation) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
Air pressure (storage/transport) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
Degree of protection | IP20 |
Designation | Axioline F connector |
---|---|
Connection method | Push-in connection |
Note on connection method | Please observe the information provided on conductor cross sections in the “Axioline F: system and installation” user manual. |
Conductor cross section solid min. | 0.2 mm² |
Conductor cross section solid max. | 1.5 mm² |
Conductor cross section flexible min. | 0.2 mm² |
Conductor cross section flexible max. | 1.5 mm² |
Conductor cross section AWG min. | 24 |
Conductor cross section AWG max. | 16 |
Net weight | 195.9 g |
---|---|
Note on weight specifications | with connector |
Mounting type | DIN rail mounting |
Fieldbus system | PROFINET |
---|---|
Designation | PROFINET |
Connection method | RJ45 socket, auto negotiation and auto crossing |
Transmission speed | 100 MBit/s (Full duplex) |
Transmission physics | Ethernet in RJ45 twisted pair |
Fieldbus system | Lokalbus |
Designation | Axioline F local bus |
Connection method | Connection for bus base module |
Transmission speed | 100 MBit/s |
Designation | Service |
Connection method | IFS-USB-PROG-ADAPTER |
Amount of process data | 1485 Byte (for each data direction) |
---|---|
Number of supported devices | max. 63 (per station) |
Number of local bus devices that can be connected | max. 63 |
Current consumption | max. 600 mA (from UBK) |
---|---|
Power loss | typ. 2 W ((without I/Os)) |
Supply of communications power UL | 24 V DC |
---|---|
Current consumption from UL | typ. 86 mA (without I/Os and UL = 24 V) |
max. 600 mA (with 2 A at UBus for the I/Os and UL = 24 V) | |
max. 750 mA (with 2 A load at UBus for the I/Os and UL = 19 V) | |
Communications power UBus | 5 V DC (via bus base module) |
Current supply at UBus | 2 A |
Título: | Tamanho: | Tipo: |
---|---|---|
PHOENIX CONTACT-2688019-AXL BK PN | 153 Kbytes |
Não há comentários do produto ainda.
Avaliação: | |
Nome: | |
Email: | |
Título: | |
Opinión: | |
Você recomendaria esse produto para comprar? | |
Adicionar avaliação |
Todas as classificações que recebemos a partir dos itens que oferecemos são reais e verificadas. Um pequeno gesto, mas muito valioso. Então, obrigado por esse minuto você gasta em deixar-nos a sua opinião e classificação de produtos, porque nos ajuda a continuar a melhorar e oferecer maior qualidade de serviço.