PT 2-TELE-ST 2838733 PHOENIX CONTACT Surge protection plug View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

PT 2-TELE-ST 2838733 PHOENIX CONTACT Surge protection plug

PT 2-TELE-ST

2838733

PHOENIX_CONTACT

Surge protection plug

More details


Trabtech (TT)

* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

Total price: $151.07
Unit price: $151.07

Quantity Price
1+$151.07
2+$129.06
3+$120.10
4+$118.92
*This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



Key Commercial Data

Orderkey2838733
Packing unit10 pc
Catalog pagePage 164 (C-4-2017)
GTIN4046356044677
Weight per Piece (excluding packing)28.940 g
Custom tariff number85363010
Country of originDE (Germany)

Dimensions

Height45 mm
Width17.7 mm
Depth52 mm
Horizontal pitch1 Div.
Complete module height90 mm
Complete module width17.7 mm
Complete module depth65.5 mm

Ambient conditions

Ambient temperature (operation)-40 °C ... 85 °C
Ambient temperature (storage/transport)-40 °C ... 85 °C
Degree of protectionIP20

General

Housing materialPA 6.6
Flammability rating according to UL 94V-0
Colorjet black RAL 9005
Mounting typeon base element
TypeMale
Number of positions2
Direction of actionLine-Line & Line-Earth Ground

Protective circuit

IEC test classificationB2
C1
C2
C3
D1
Nominal voltage UN185 V DC
130 V AC
Maximum continuous voltage UC185 V DC
130 V AC
Rated current450 mA AC (45°C)
130 mA DC (45°C)
Operating effective current ICat UC≤ 10 µA
Residual current IPE≤ 10 µA
Nominal discharge current In(8/20) µs (line-line)10 kA
Nominal discharge current In(8/20) µs (line-earth)10 kA
Pulse discharge current Iimp(10/350) µs (line-line)1 kA
Pulse discharge current Iimp(10/350) µs (line-earth)1 kA
Total discharge current Itotal(8/20) µs18 kA
Max. discharge current Imax(8/20) µs maximum (line-earth)18 kA
Nominal pulse current Ian (10/700) µs (line-line)100 A
Nominal pulse current Ian (10/700) µs (line-earth)100 A
Output voltage limitation at 1 kV/µs (line-line) spike≤ 300 V
Output voltage limitation at 1 kV/µs (line-earth) spike≤ 300 V
Output voltage limitation at 1 kV/µs (line-line) static≤ 300 V
Output voltage limitation at 1 kV/µs (line-earth) static≤ 300 V
Residual voltage at In(line-line)≤ 160 V (C2 - 10 kV / 5 kA)
Residual voltage at In(line-earth)≤ 200 V (C2 - 10 kV / 5 kA)
Voltage protection level Up(line-line)≤ 250 V (B2 - 1 kV / 25 A)
≤ 300 V (B2 - 4 kV / 100 A)
≤ 270 V (C1 - 1 kV/500 A)
≤ 300 V (C2 - 2 kV/1 kA)
≤ 320 V (C2 - 4 kV / 2 kA)
≤ 330 V (C2 - 10 kV / 5 kA)
Voltage protection level Up(line-earth)≤ 250 V (B2 - 1 kV / 25 A)
≤ 300 V (B2 - 4 kV / 100 A)
≤ 270 V (C1 - 1 kV/500 A)
≤ 300 V (C2 - 2 kV/1 kA)
≤ 320 V (C2 - 4 kV / 2 kA)
≤ 330 V (C2 - 10 kV / 5 kA)
Response time tA(line-line)≤ 500 ns
Response time tA(line-earth)≤ 500 ns
Input attenuation aE, sym.typ. 0.4 dB (≤ 5 MHz / 100 Ω)
Cut-off frequency fg (3 dB), sym. in 100 Ohm systemtyp. 20 MHz
Capacity (line-line)typ. 30 pF (f=1 MHz / VR= 0 V)
Capacity (line-earth)typ. 30 pF (f=1 MHz / VR= 0 V)
Surge protection fault messagenone
Impulse durability (line-line)B2 - 4 kV/100 A
C1 - 1 kV/500 A
C2 - 10 kV/5 kA
C3 - 25 A
D1 - 1 kA
Impulse durability (line-earth)B2 - 4 kV/100 A
C1 - 1 kV/500 A
C2 - 10 kV/5 kA
C3 - 25 A
D1 - 1 kA

Connection data

Connection methodpluggable

Standards and Regulations

Standards/specificationsIEC 61643-21 2000
EN 61643-21 2002

Environmental Product Compliance

China RoHSEnvironmentally friendly use period: unlimited = EFUP-e
No hazardous substances above threshold values

Classifications

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.