AXL F SSI1 AO1 1H 2688433 PHOENIX CONTACT Axioline˽F special function module, 1 SSI interface for absolute e.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

AXL F SSI1 AO1 1H 2688433 PHOENIX CONTACT Axioline˽F special function module, 1 SSI interface for absolute e..

AXL F SSI1 AO1 1H

2688433

PHOENIX_CONTACT

Available

Ship on today

Axioline˽F special function module, 1 SSI interface for absolute encoder, 1 analog output: 0-10 V, ±10 V, 0-5 V, ±5 V, 0-20 mA, 4-20 mA, ±20 mA, 2-wire connection method (including bus base module and connectors)

More details


Programmable Logic Controllers Plcs

* Brand new produt in its original packing covered by the warranties and certifications provided by PHOENIX_CONTACT

QuantityPrice
1+$252.86
2+$246.96
3+$244.04
4+$243.58
*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



Product description

The module is designed for use within an Axioline˽F station.

It is used to acquire data from absolute encoders with SSI interface with a maximum resolution of up to

56 bits.

The module supports encoders with Gray and binary code. Transmission speeds of up to 2 MHz are supported.

In addition, the module has an analog output which can be used to specify setpoints, e.g., for electrical and hydraulic drives.

Dimensions

Width35 mm
Height126.1 mm
Depth54 mm
Note on dimensionsThe depth is valid when a TH 35-7.5 DIN rail is used (according to EN 60715).

Ambient conditions

Ambient temperature (operation)-25 °C ... 60 °C
Ambient temperature (storage/transport)-40 °C ... 85 °C
Permissible humidity (operation)5 % ... 95 % (non-condensing)
Permissible humidity (storage/transport)5 % ... 95 % (non-condensing)
Air pressure (operation)70 kPa ... 106 kPa (up to 3000 m above sea level)
Air pressure (storage/transport)70 kPa ... 106 kPa (up to 3000 m above sea level)
Degree of protectionIP20

Connection data

DesignationAxioline F connector
Connection methodPush-in connection
Note on connection methodPlease observe the information provided on conductor cross sections in the “Axioline F: system and installation” user manual.
Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.1.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.1.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.16
Stripping length8 mm

General

Net weight135 g
Note on weight specificationswith connectors and bus base module
Mounting typeDIN rail

Interfaces

DesignationAxioline F local bus
Connection methodBus base module
Transmission speed100 MBit/s

Axioline potentials

Communications power UBus5 V DC (via bus base module)
Current consumption from UBusmax. 140 mA
Supply of digital input modules UI24 V DC
Current consumption from UImax. 60 mA (Supply of the SSI interface and the analog output (20 mA), without sensor supply)

Encoder inputs

Input nameSSI interface
Description of the inputRS-422 interface according to SSI specification
Number of inputs1
Connection methodPush-in connection
Encoder signalsSingle-turn and multi-turn encoder, length measuring sticks
Input frequencyto 2 MHz (Can be parameterized: 67.5 kHz, 125 kHz (default), 250 kHz, 500 kHz, 1 MHz, 2 MHz)
ParityEven, odd or no parity
Transmission frequency2 MHz
Adjustable resolution8 ... 56
Encoder supply voltage24 V DC (UI - 0.5 V)

Encoder data

Nominal output voltage24 V DC (UI - 0.5 V)
Voltage range19.5 V DC ... 30 V DC (including all tolerances, including ripple)
Current carrying capacitymax. 500 mA
Type of protectionSurge protection
Protective circuit/componentElectronic (35 V, 0.5 s)

Analog outputs

Number of outputs1
Connection methodPush-in connection
2-wire (shielded, twisted pair)
Output nameAnalog outputs
D/A conversion time5 µs
D/A resolution16 bit
Type of protectionSurge protection
Short-circuit and overload protection
Transient protection
Protective circuit/componentElectronic (35 V, permanent)
Electronic
Suppressor diode
Data formatsIB IL, S7-compatible, standardized representation
Measured value representation16 bits
Representation of output values16 bits (15 bits + sign)
Current output signal0 mA ... 20 mA
4 mA ... 20 mA
-20 mA ... 20 mA
Load/output load current outputmax. 500 Ω
Voltage output signal0 V ... 5 V
-5 V ... 5 V
0 V ... 10 V
-10 V ... 10 V
Load/output load voltage output> 2 kΩ
Precisiontyp. 0.1 % (of output range final value)
typ. 0.1 % (of output range final value)
Permissible cable lengthmax. 250 m

Datasheet - PDF

Title:Language:Size:Type:
PHOENIX CONTACT-2688433-AXL F SSI1 AO1 1HEnglish164 KbytesPHOENIX CONTACT-2688433-AXL F SSI1 AO1 1H

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review
Have you got any questions?

If you have any questions, you can visit the following links or contact us via email

Please wait





* Required fields

or