DS6-340-90K-MX 103152 EATON ELECTRIC SOFT STARTER 90KW View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

DS6-340-90K-MX 103152 EATON ELECTRIC SOFT STARTER 90KW

DS6-340-90K-MX

103152

EATON-MOELLER

SOFT STARTER 90KW

More details


Home > EATON - MOELLER

* Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

Go to successor article: DS7-340SX160N0-N 134922

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



Delivery programme
Description
With internal bypass contacts
Function
Soft starters for three-phase loads
Mains supply voltage (50/60 Hz)
ULN V AC 230 - 480
Supply voltage
Us 24 V DC
Control voltage
UC 24 V DC
Assigned motor rating (Standard connection, In-Line)
at 400 V, 50 Hz
P kW 90
at 460 V, 60 Hz
P HP 125
Rated operational current
AC-53
Ie A 161
Startup class
CLASS 10 (star-delta replacement)
CLASS 20 (heavy starting duty 3 x Iefor 45 s)
Rated operational voltage
Ue 230 V
400 V
480 V
Technical data
General
Standards
IEC/EN 60947-4-2
UL 508
CSA22.2-14
GB14048
Approvals
CE
Approvals
UL
CSA
C-Tick
UkrSEPRO
CCC
Climatic proofing
Damp heat, constant, to IEC 60068-2-3
Damp heat, cyclic, to IEC 60068-2-10
Ambient temperature
Operation
ϑ °C 0 - +40
up to 60 at 1 % derating per Kelvin temperature rise
Storage
ϑ °C -25 - +55
Altitude
m 0 - 1000 m, above that 1 % derating per 100 m , up to 2000 m
Mounting position
Vertical
Degree of protection
Degree of Protection
IP20 (terminals IP00)
Integrated
Protection type IP40 can be achieved on all sides with covers from the NZM range.
Protection against direct contact
Finger and back-of-hand proof
Overvoltage category/pollution degree
II/2
Shock resistance
8 g/11 ms
Vibration resistance to EN 60721-3-2
2M2
Radio interference level (IEC/EN 55011)
A
Weight
kg 3.7
Main conducting paths
Rated operating voltage
Ue V AC 230 - 480
Supply frequency
fLN Hz 50/60
Rated operational current
Ie A
AC-53
Ie A 161
Assigned motor rating (Standard connection, In-Line)
at 230 V, 50 Hz
P kW 45
at 400 V, 50 Hz
P kW 90
at 230 V, 60 Hz
P HP 60
at 460 V, 60 Hz
P HP 125
Overload cycle to IEC/EN 60947-4-2
AC-53a
160 A: AC-53a: 3 - 5: 75 - 10
Internal bypass contacts
Short-circuit rating
Type “1” coordination
NZMN2-M200
Type „2“ coordination (additional with the fuses for coordination type „1“)
3 x 20.610.32-400
Fuse base (number x part no.)
3 x 21.313.02
Terminal capacities
Cable lengths
Solid
mm2 1 x (4 - 185)
2 x (4 - 70)
Stranded
mm2 1 x (4 - 185)
2 x (4 - 70)
Solid or stranded
AWG 1 x (12 - 350 kcmil)
2 x (12 - 00)
Copper band
MM 2 x 9 x 0.8 10 x 16 x 0.8
Tightening torque
Nm 5 (≤ 10 mm²); 14 (> 10 mm²)
Screwdriver (PZ: Pozidriv)
mm PZ2;1 x 6 mm
Control cables
Solid
mm2 1 x (0.5 - 2.5)
2 x (0.5 - 1.0)
Flexible with ferrule
mm2 1 x (0.5 - 1.5)
2 x (0.5 - 0.75)
Stranded
mm2 1 x (0.5 - 1.5)
2 x (0.5 - 1.0)
Solid or stranded
AWG 1 x (21 - 14)
2 x (21 - 18)
Tightening torque
Nm 0.4
Screwdriver
mm 0,6 x 3,5
Control circuit
Digital inputs
Control voltage
DC-operated
V DC 24 V DC +10 %/- 15 %
Current consumption 24 V
mA
External 24 V (no-load)
mA 14
Pick-up voltage
x Us
DC-operated
V DC 17.3 - 27
Drop-out voltage
x Us
DC operated
V DC 0 - 3
Pick-up time
DC operated
ms 250
Drop-out time
DC operated
ms 190
Regulator supply
Voltage
Us V 24 V DC +10 %/- 15 %
Current consumption
Ie mA 65
Current consumption at peak performance (close bypass) at 24 V DC
IPeak A/ms 0,6/50
Notes
External supply voltage
Relay outputs
Number
2 (TOR, Ready)
Voltage range
V AC 250
AC-11 current range
A 3 A, AC-11
Soft start function
Ramp times
Acceleration
s 1 - 30
Deceleration
s 0 - 30
Start voltage (= turn-off voltage)
% 30 100
Start pedestal
% 30 - 100
Fields of application
Fields of application
Soft starting of three-phase asynchronous motors
3-phase motors
Functions
Fast switching (semiconductor contactor)
- (minimum ramp time 1s)
Soft start function
Reversing starter
External solution required
Suppression of closing transients
Suppression of DC components for motors
Potential isolation between power and control sections
Notes


Rated impulse withstand voltage:

  • 1.2 µs/50 µs (rise time/fall time of the pulse to IEC/EN 60947‐2 or ‐3)
  • Applies for control circuit/power section/enclosure
Technical data ETIM 6.0(Show features)(Hide features)
Low-voltage industrial components (EG000017) / Soft starter (EC000640)
Electric engineering, automation, process control engineering / Low-voltage switch technology / Load breakout, motor breakout / Semiconductor motor controller or soft starter ([email protected] [ACO300008])
Rated operation current Ie at 40 °C Tu
A 160
Rated operating voltage Ue
V 230 - 460
Rated power three-phase motor, inline, at 230 V
kW 45
Rated power three-phase motor, inline, at 400 V
kW 90
Rated power three-phase motor, inside delta, at 230 V
kW 0
Rated power three-phase motor, inside delta, at 400 V
kW 0
Internal bypass
Yes
With display
No
Torque control
No
Rated surrounding temperature without derating
°C 40
Rated control supply voltage Us at AC 50HZ
V 0 - 0
Rated control supply voltage Us at AC 60HZ
V 0 - 0
Rated control supply voltage Us at DC
V 24 - 24
Voltage type for actuating
DC
Integrated motor overload protection
No
Approvals
Product Standards IEC/EN 60947-4-2; GB 14048.6; UL 508; CSA-C22.2 No 0-M91; CSA-C22.2 No 14-05 CE marking
UL File No. E251034
UL Category Control No. NMFT
CSA File No. 012528
CSA Class No. 3211-06
North America Certification UL listed, CSA certified
Specially designed for North America No
Suitable for Branch circuits
Current Limiting Circuit-Breaker No
Max. Voltage Rating 480 V
Degree of Protection IP20; UL/CSA Type 1
Dimensions
AWA8250-2330 Soft starter DS6
>
>
>>

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.