Product successfully added to your shopping cart
ELC-PS01
135239
EATON-MOELLER
1
transformers
Home > EATON - MOELLER
* Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
Product range | Power supplies ELC-PS | ||
Subrange | power supply unit | ||
Phases | Single-phase | ||
Input voltage range | 85 - 264 V AC | ||
Nominal input voltage | 100 - 240 V AC | ||
Rated output voltage | 24 V DC (± 3%) | ||
Rated output current | A | 1 | |
Rated output power | W | 24 |
Input characteristics | |||
Nominal input voltage | 100 - 240 V AC | ||
Output characteristics | |||
Rated output power | W | 24 | |
Rated output voltage | 24 V DC (± 3%) | ||
Heat dissipation | W | 6 |
Technical data for design verification | |||
Rated operational current for specified heat dissipation | In | A | 0 |
Heat dissipation per pole, current-dependent | Pvid | W | 0 |
Equipment heat dissipation, current-dependent | Pvid | W | 0 |
Static heat dissipation, non-current-dependent | Pvs | W | 6 |
Heat dissipation capacity | Pdiss | W | 0 |
Operating ambient temperature min. | °C | 0 | |
Operating ambient temperature max. | °C | 50 | |
IEC/EN 61439 design verification | |||
10.2 Strength of materials and parts | |||
10.2.2 Corrosion resistance | Meets the product standard's requirements. | ||
10.2.3.1 Verification of thermal stability of enclosures | Meets the product standard's requirements. | ||
10.2.3.2 Verification of resistance of insulating materials to normal heat | Meets the product standard's requirements. | ||
10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects | Meets the product standard's requirements. | ||
10.2.4 Resistance to ultra-violet (UV) radiation | Meets the product standard's requirements. | ||
10.2.5 Lifting | Does not apply, since the entire switchgear needs to be evaluated. | ||
10.2.6 Mechanical impact | Does not apply, since the entire switchgear needs to be evaluated. | ||
10.2.7 Inscriptions | Meets the product standard's requirements. | ||
10.3 Degree of protection of ASSEMBLIES | Meets the product standard's requirements. | ||
10.4 Clearances and creepage distances | Meets the product standard's requirements. | ||
10.5 Protection against electric shock | Does not apply, since the entire switchgear needs to be evaluated. | ||
10.6 Incorporation of switching devices and components | Does not apply, since the entire switchgear needs to be evaluated. | ||
10.7 Internal electrical circuits and connections | Is the panel builder's responsibility. | ||
10.8 Connections for external conductors | Is the panel builder's responsibility. | ||
10.9 Insulation properties | |||
10.9.2 Power-frequency electric strength | Is the panel builder's responsibility. | ||
10.9.3 Impulse withstand voltage | Is the panel builder's responsibility. | ||
10.9.4 Testing of enclosures made of insulating material | Is the panel builder's responsibility. | ||
10.10 Temperature rise | The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. | ||
10.11 Short-circuit rating | Is the panel builder's responsibility. | ||
10.12 Electromagnetic compatibility | Is the panel builder's responsibility. | ||
10.13 Mechanical function | The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
Low-voltage industrial components (EG000017) / DC-power supply (EC002540) | |||
Electric engineering, automation, process control engineering / Power supply / Power supply (other) / DC-power supply ([email protected] [AFZ644012]) | |||
Voltage type of supply voltage | AC | ||
1st secondary output voltage | V | 24 - 24 | |
2nd secondary output voltage | V | 0 - 0 | |
3rd secondary output voltage | V | 0 - 0 | |
Max. output current 1 | A | 1 | |
Max. output current 2 | A | 0 | |
Max. output current 3 | A | 0 | |
Secondary voltage adjustable | Yes | ||
Nominal value output voltage 1 | V | 24 | |
Nominal value output voltage 2 | V | 0 | |
Nominal value output voltage 3 | V | 0 | |
Nominal value output current 1 | A | 1 | |
Nominal value output current 2 | A | 0 | |
Nominal value output current 3 | A | 0 | |
Short-circuit-proof | Yes | ||
Rated supply voltage at AC 50 Hz | V | 85 - 264 | |
Rated supply voltage at AC 60 Hz | V | 85 - 264 | |
Rated supply voltage at DC | V | 0 - 0 | |
Output voltage stabilized | No | ||
Power consumption | VA | 0 | |
Power output | W | 24 | |
Stabilized | Yes | ||
Type of electric connection | Screw connection | ||
Rail mounting possible | Yes | ||
Wall mounting possible | No | ||
Modular version | Yes | ||
Width in number of modular spacings | 0 | ||
Built-in width | mm | 36.5 | |
Built-in height | mm | 90 | |
Direct mounting possible | No | ||
Width | mm | 36.5 | |
Height | mm | 90 | |
Depth | mm | 60 | |
Suitable for safety functions | No | ||
SIL according to IEC 61508 | None | ||
Performance level acc. to EN ISO 13849-1 | None | ||
Degree of protection (IP) | - |
Title: | Size: | Type: |
---|---|---|
PDF CATALOGUE EATON EN.pdf | 51 Mbytes |
No customer reviews for the moment.
Rating: | |
Name: | |
Email: | |
Subject: | |
Text: | |
Do you recommend this product to buy? | |
Add review |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.