Product name
Eaton Moeller® series M22 Key-operated actuator
Product Length/Depth
130 millimetre
Product height
70 millimetre
Product width
72 millimetre
Product weight
0.2 kilogram
Certifications
IEC/EN 60947-5
CSA-C22.2 No. 14-05
CSA
CSA-C22.2 No. 94-91
CSA Class No.: 3211-03
CSA File No.: 012528
UL
UL Category Control No.: NKCR
UL 508
CE
IEC/EN 60947
VDE 0660
UL File No.: E29184
Product Type
Key-operated actuator
Catalog Notes
Contacts with safety function, by positive opening to IEC/EN 60947-5-1
Key withdraw convertible with coding adapters M22-XC-...
Not suitable for master key systems
Enclosure material
Plastic
Functions
Stay-put/spring-return function, can be changed with coding parts M22-XC-Y
Knockouts
2 x M25/20 (cable entry knockouts at the side)
1 x M20 (cable entry knockout at the side)
2 x M16 (cable entry knockouts at the base)
Accessories
1 key included with supplied equipment.
Degree of protection
IP66
NEMA 4X, 13
Lifespan
100,000 mechanical Operations
Operating frequency
100 Operations/h
Product category
RMQ-Titan
Size
Front diameter: 29.7 mm
Type
Housing
Key-operated button
Ambient conditions, mechanical
Mounting position
As required
Shock resistance
30 g, Mechanical, According to IEC/EN 60068-2-27, Sinusoidal shock 11 ms
Mechanical, According to IEC/EN 60068-2-27
Climatic environmental conditions
Ambient operating temperature - min
-25 °C
Ambient operating temperature - max
70 °C
Climatic proofing
Damp heat, cyclic, to IEC 60068-2-30
Damp heat, constant, to IEC 60068-2-78
Rated control supply voltage (Us) at AC, 50 Hz - min
115 V
Rated control supply voltage (Us) at AC, 50 Hz - max
500 V
Rated control supply voltage (Us) at AC, 60 Hz - min
115 V
Rated control supply voltage (Us) at AC, 60 Hz - max
500 V
Rated control supply voltage (Us) at DC - min
24 V
Rated control supply voltage (Us) at DC - max
220 V
Rated conditional short-circuit current (Iq)
1 kA
Connection to SmartWire-DT
No
Connection type
Screw connection
Actuator function
Key withdrawable in position 0
Key withdrawable in position 1
Maintained
Actuator travel and actuation force (DIN EN 60947-5-1)
4.8 mm
Number of actuation directions
2
Force for positive opening - min
20 N
Number of contacts (change-over contacts)
0
Number of contacts (normally closed contacts)
1
Number of contacts (normally open contacts)
1
Equipment heat dissipation, current-dependent Pvid
0 W
Heat dissipation capacity Pdiss
0 W
Heat dissipation per pole, current-dependent Pvid
0.11 W
Rated operational current for specified heat dissipation (In)
6 A
Static heat dissipation, non-current-dependent Pvs
0 W
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Please enquire
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.