SACC-E-M12MS-3P-M20/0,5/0,15VA 1413927 PHOENIX CONTACT Sensor/atuador painel conector de montagem, de 3 pos... Ver maior
As imagens são só a título ilustrativo. Por favor, consulte a ficha técnica.

SACC-E-M12MS-3P-M20/0,5/0,15VA 1413927 PHOENIX CONTACT Sensor/atuador painel conector de montagem, de 3 pos...

SACC-E-M12MS-3P-M20/0,5/0,15VA

1413927

PHOENIX_CONTACT

Sensor/atuador painel conector de montagem, de 3 pos., M12, Uma codificado, frente/montagem do parafuso M20 x 1,5 rosca, com 0,15 m de PVC litz fios, 3 x 0,5 mm2, incluindo anilhas com colarinho de plástico, de aço inoxidável versão

Conecte. ficha. para ser apar. parede frontal, 3 polos, conector macho, M12, codificação: A, Montagem frontal, Fios trançados simples, comprimento do cabo: 0,15 m, 0,50 mm², condutor em PVC

Sensor/actuator panel-mount connector, 3-pos., M12, A-coded, front/screw mounting with M20 x 1.5 thread, with 0.15 m PVC litz wires, 3 x 0.5 mm² including ferrules with plastic collar, stainless steel version

Mais detalhes


Conectores > Condutor circular, de montagem (com fios)

Conexão de dispositivos de campo

Produto novo em sua embalagem original com todas as garantias e certificações de PHOENIX_CONTACT

* Este artigo pode estar obsoleto. Se você estiver interessado, insira seu e-mail e informaremos se há unidades disponíveis. Caso não existam mais, um dos nossos técnicos procurará uma alternativa fornecivel com características semelhantes.

Se o nosso preço não é o melhor, peça-nos uma cotação Solicitar uma cotação

Related products

Best sellers

Mais informação



Dados comerciais

Chave de encomenda1413927
Quantidade de embalagem1
GTIN (EAN)4055626012087
Número do imposto alfandegário85444290

Desenhos



Dimensional drawing

Dimensional drawing
M12 flush-type plug

Dimensional drawing

Dimensional drawing
Housing cutout for M20 fastening thread, mounting panel with thread



Circuit diagram

Circuit diagram
Contact assignment of the M12 plug and the M12 socket

Schematic diagram

Schematic diagram
Pin assignment M12 plug, 4-pos., A-coded, view plug side



Voltar para cima

Dimensions

Length of cable0.15 m
Voltar para cima

Ambient conditions

Ambient temperature (operation)-25 °C ... 85 °C (Plug / socket)
-40 °C ... 85 °C (without mechanical actuation)
Voltar para cima

General

NoteThe electrical and mechanical data specified assume that the connector pair is correctly locked and mounted. If the connector is unlocked and if there is a danger of contamination, the connector must be sealed using a protective cap > IP54. Influences arising from litz wires, cables or PCB assembly must also be taken into consideration.
Rated current at 40°C4 A
Rated voltage250 V
Rated surge voltage2.5 kV
Number of positions3
Insulation resistance≥ 100 MΩ
CodingA - standard
Standards/regulationsM12 connector IEC 61076-2-101
Overvoltage categoryII
Degree of pollution3
Connection methodIndividual wires
Insertion/withdrawal cycles> 100
Voltar para cima

Material

Flammability rating according to UL 94V0
Contact materialCuZn
Contact surface materialAu
Contact carrier materialPA 6.6
Material, knurlsStainless steel
Sealing materialHNBR
Voltar para cima

Cable

Cable typePVC litz wire
Conductor cross section0.5 mm²
AWG signal line20
Core diameter including insulation2.5 mm
Wire colorsbrown, blue, black
Material conductor insulationTPE
Conductor materialTin-plated Cu litz wires
Standards/specificationsM12 connector IEC 61076-2-101
Nominal voltage, cable300 V
Test voltage, cable2000 V AC
Ambient temperature (operation)-40 °C ... 70 °C (cable, fixed installation)
Voltar para cima

Standards and Regulations

Standards/specificationsM12 connector IEC 61076-2-101
Flammability rating according to UL 94V0
Safety noteWARNING: The connectors may not be plugged in or disconnected under load. Ignoring the warning or improper use may damage persons and/or property.
• WARNING: Commission properly functioning products only. The products must be regularly inspected for damage. Decommission defective products immediately. Replace damaged products. Repairs are not possible.
• WARNING: Only electrically qualified personnel may install and operate the product. They must observe the following safety notes. The qualified personnel must be familiar with the basics of electrical engineering. They must be able to recognize and prevent danger. The relevant symbol on the packaging indicates that only personnel familiar with electrical engineering are allowed to install and operate the product.
• The products are suitable for applications in plant, controller, and electrical device engineering.
• When operating the connectors in outdoor applications, they must be separately protected against environmental influences.
• Assembled products may not be manipulated or improperly opened.
• Only use mating connectors that are specified in the technical data of the standards listed (e.g. the ones listed in the product accessories online at phoenixcontact.com/products).
• When using the product in direct connection with third-party manufacturers, the user is responsible.
• For operating voltages > 50 V AC, conductive connector housings must be grounded
• Ensure that when laying the cable, the tensile load on the connectors does not exceed the upper limit specified in the standards.
• Observe the corresponding technical data. You will find information:
o On the product
o On the packing label
o In the supplied documentation
o Online at phoenixcontact.com/products under the product
• Only use tools recommended by Phoenix Contact
• Use a protective cap to protect connectors that are not in use. The suitable accessories are available online in the accessory section of the product at phoenixcontact.com/products
• Ensure that the protective or functional ground has been properly connected.
• VDE 0100/1.97 § 411.1.3.2 and DIN EN 60 204/11.98 § 14.1.3 are applicable when combining several circuits in a cable and/or connector
• The connector warms up in normal operation. Depending on the ambient conditions, the surface of the connector can continue to warm up. In this case, the user is responsible for posting warnings (e.g. DIN EN ISO 13732-1:2008-12).
Voltar para cima

Environmental Product Compliance

REACh SVHC
Lead 7439-92-1
China RoHSEnvironmentally Friendly Use Period = 50
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Voltar para cima

Classificações

eCl@ss

eCl@ss 10.0.127440102
eCl@ss 4.027140800
eCl@ss 4.127140800
eCl@ss 5.027143400
eCl@ss 5.127143400
eCl@ss 6.027279200
eCl@ss 7.027440103
eCl@ss 8.027440103
eCl@ss 9.027440102
Voltar para cima

ETIM

ETIM 5.0EC002061
ETIM 6.0EC002061
Voltar para cima

UNSPSC

UNSPSC 13.239121413
UNSPSC 18.039121413
UNSPSC 19.039121413
UNSPSC 20.039121413
UNSPSC 21.039121413
Voltar para cima

ETIM for 1413927 Ligadores (EC003570)
Característica Valor
Comprimento do cabo (EF000536) 0.15 mm
Método de montagem (EF000003) Montagem frontal
Material da caixa protetora (EF001596) Outro
Material do isolamento do condutor (EF000061) Outro
Material da superfície de contato (EF004020) Outro
Classe de inflamabilidade do material de selagem de acordo com UL 94 (EF002521) V0
Temperatura ambiente (EF002386) 85 °C
Temperatura de operação (EF002393) -25 °C
Tensão especificada de funcionamento (EF000228) 250 V
Com conexão blindada (EF002535) Não
Rosca aparafusada (EF012303) M12
Secção transversal do núcleo (EF000018) 0.5 mm²
Min. número de ciclos de inserção (EF012212) 100
Grau de proteção (IP), montado (EF007466) IP69K

Datasheet - PDF

Título: Tamanho: Tipo:
PDF CATALOG PHOENIX CONNECTORS EN.pdf 68 Mbytes

Avaliações: (0)

Não há comentários do produto ainda.

Adicionar avaliação
ocultar formulário
Avaliação:
Nome:
Email:
Título:
Opinión:
  Captcha
  Adicionar avaliação

Todas as classificações que recebemos a partir dos itens que oferecemos são reais e verificadas. Um pequeno gesto, mas muito valioso. Então, obrigado por esse minuto você gasta em deixar-nos a sua opinião e classificação de produtos, porque nos ajuda a continuar a melhorar e oferecer maior qualidade de serviço.