ANUNCIAR
VS-M12MSD/5,0-93X/M12MSDOD 1454244 PHOENIX CONTACT Cabo de rede Ver maior
As imagens são só a título ilustrativo. Por favor, consulte a ficha técnica.

VS-M12MSD/5,0-93X/M12MSDOD 1454244 PHOENIX CONTACT Cabo de rede

VS-M12MSD/5,0-93X/M12MSDOD

1454244

PHOENIX_CONTACT

Cabo de rede

Cabo de rede, PROFINET CAT5 (100 MBit/s), Ethernet CAT5 (100 MBit/s), 4 polos sem halogênio, blindado, conector reto M12, codificação: D / IP69K, para conector reto M12, codificação: D / IP69K, comprimento do cabo: 5 m, para aplicações externas, com serrilhado em aço inoxidável

Network cable, PROFINET CAT5 (100 Mbps), Ethernet CAT5 (100 Mbps), 4-position, PE-X halogen-free, black RAL 9005, shielded, Plug straight M12, coding: D / IP69K, on Plug straight M12, coding: D / IP69K, cable length: 5 m, for outdoor applications, with high-grade steel knurl

Mais detalhes


Sensores > Cabo do sensor-atuador pré-fabricado

Cabos, sensores e atuadores

Produto novo em sua embalagem original com todas as garantias e certificações de PHOENIX_CONTACT

Preço total: $168.48
Preço unitário: $168.48
Este preço é por unidade e mostra o valor líquido (excluindo impostos indirectos se aplicável).

Se o nosso preço não é o melhor, peça-nos uma cotação Solicitar uma cotação

Best sellers

Mais informação



Dados técnicos

Product properties
Product typeData cable preassembled
ApplicationExternal areas
Sensor typePROFINET
Number of positions4
No. of cable outlets1
Shieldedyes
CodingD
Insulation characteristics
Degree of pollution3

Interfaces
Bus systemPROFINET
Ethernet
Signal type/categoryPROFINET CAT5 (IEC 11801), 100 Mbps
Ethernet CAT5 (IEC 11801), 100 Mbps

Signaling
Status displayno
Status display presentNo

Electrical properties
Nominal voltage UN48 V AC
60 V DC
Nominal current IN4 A
Transmission mediumCopper

Mechanical properties
Mechanical data
Insertion/withdrawal cycles≥ 100

Material specifications
Flammability rating according to UL 94V0

Connector
Connection 1
TypePlug straight M12 / IP69K
Number of positions4 (4)
Coding typeD (Data)
Shieldedyes
Handle colorblack
MaterialCuZn (Contact)
Ni/Au (Contact surface)
PA (Contact carriers)
TPU, hardly inflammable, self-extinguishing (Grip body)
Stainless steel (Screw connection)
Degree of protectionIP69K
Connection 2
TypePlug straight M12 / IP69K
Number of positions4 (4)
Coding typeD (Data)
Shieldedyes
Handle colorblack
MaterialCuZn (Contact)
Ni/Au (Contact surface)
PA (Contact carriers)
TPU, hardly inflammable, self-extinguishing (Grip body)
Zinc die-cast, nickel-plated (Screw connection)
Degree of protectionIP69K

Cable/line
Cable length5 m
PROFINET outdoors [93X]
Desenho cotadojtvtrckflp.jpg
Cable weight81 g/m
Shieldedyes
Cable typePROFINET outdoors [93X]
Conductor structure1x4xAWG22/7, SF/TQ
Signal speed66 c
Conductor structure signal line7x 0.25 mm
AWG signal line22
Conductor cross section4x 0.34 mm²
Wire diameter incl. insulation1.95 mm
External cable diameter7.25 mm ±0.3 mm
Outer sheath, materialPE-X
External sheath, colorblack RAL 9005
Conductor materialsilver-plated Cu litz wires
Material wire insulationPE-X
Single wire, colorwhite-blue, orange-yellow
Thickness, outer sheath≥ 0.80 mm
Overall twistStar quad
Optical shield covering100 %
Max. conductor resistance≤ 54.4 Ω/km
Coupling resistance200.00 mΩ/m (f ≤ 30 MHz)
Wave impedance100 Ω ±5 Ω (f = 100 MHz)
Working capacitance≤ 65 pF (Line-line)
≤ 100 pF (Line-shield)
Nominal voltage, cable300 V AC
Test voltage2000 V AC (50 Hz, 5 minutes)
Minimum bending radius, fixed installation6 x D
Minimum bending radius, flexible installation10 x D
Smallest bending radius, fixed installation44 mm
Smallest bending radius, movable installation73 mm
Shield attenuation40.00 dB (30 MHz ≤ f ≤ 100 MHz)
Halogen-freein accordance with EN 50267-2-1
Flame resistanceEN 60332-1-2
EN 50266
EN 60332-3-25
NF C32-070, 2.1
NF C32-070, 2.2
UL 1685, 12 (FT4)
in accordance with ISO 6722-1 5.22 (UN ECE-R 118.01)
Fume corrosivenessEN 50267-2-2
Fume toxicityBS 6853 B.1
EN 50305, 9.2
Concentration of fumesBS 6853 D.8.7
EN 61034-2
UL 1685, 12 (FT4)
Resistance to oilaccording to IRM 902, 72 h at 100 °C
Fire protection in rail vehiclesBS 6853 (Category Ia, Ib, II)
GM/RT 2130 (Category Ia, Ib, II)
EN 45545 (Risk level HL1 - HL3)
DIN 5510 (Fire protection level 1, 2, 3, 4)
NF F16-101 (Category A1, A2, B)
NF F16-101 (Class C/F0)
NFPA 130
UNI CEI 11170 (Risk level LR1 - LR4)
Other resistanceResistance to fuels (according to IRM 903, 168 h at 70 °C)
Ambient temperature (operation)-50 °C ... 90 °C (cable, fixed installation)
-40 °C ... 90 °C (Cable, flexible installation)

Environmental and real-life conditions
Ambient conditions
Degree of protectionIP65
IP67
IP68
IP69K
Ambient temperature (operation)-40 °C ... 105 °C
-40 °C ... 90 °C (cable, fixed installation)
-25 °C ... 90 °C (Cable, flexible installation)
-40 °C ... 85 °C (On sudden changes in temperature (according to IEC 60512-11-4))

Standards and regulations
Standard designationM12 connector
Standards/specificationsIEC 61076-2-101

Datasheet - PDF

Avaliações: (0)

Não há comentários do produto ainda.

Adicionar avaliação
ocultar formulário
Avaliação:
Nome:
Email:
Título:
Opinión:
  Captcha
  Adicionar avaliação

Todas as classificações que recebemos a partir dos itens que oferecemos são reais e verificadas. Um pequeno gesto, mas muito valioso. Então, obrigado por esse minuto você gasta em deixar-nos a sua opinião e classificação de produtos, porque nos ajuda a continuar a melhorar e oferecer maior qualidade de serviço.