HDFKV 95-F-VP T45
1712236
PHOENIX_CONTACT
10
Conector passa-muros, número de pólos: 1
Panel feed-through terminal block, connection method: Screw connection with tension sleeve, Cable lug connection, number of positions: 1, load current: 232 A, connection direction of the conductor to plug-in direction: -90 °
Conectores PCB
Produto novo em sua embalagem original com todas as garantias e certificações de PHOENIX_CONTACT
Obrigado pelo seu interesse nos nossos artigos, esperamos que o prazo indicado seja conveniente para si.
Durante a preparação do pedido pode seleccionar o tipo de envío que melhor se adapte ás suas necessidades: Aéreo Express 24Hrs, Terrestre Standard 48/72Hrs, etc.
| Product type | Panel feed-through terminal block |
| Product family | HDFKV 95-VP |
| Number of positions | 1 |
| Pitch | 25 mm |
| Number of connections | 2 |
| Number of potentials | 1 |
| Nominal current IN | 232 A |
| Degree of pollution | 3 |
| Conductor connection exterior | |
| Connection method | Screw connection with tension sleeve |
| Connection direction of the conductor to plug-in direction | -90 ° |
| Conductor connection interior | |
| Connection method | Cable lug connection |
| Connection direction of the conductor to plug-in direction | 0 ° |
| Material data - housing | |
| Color () | () |
| Insulating material | PA |
| Note on application | To maintain the nominal voltage, align the cable lugs straight and centered, and cast the terminals on the inside. |
| Safety note | |
| Safety note | • Only electrically qualified personnel may install and operate the product. To recognize and prevent danger, the qualified personnel must be familiar with the basics of electrical engineering. |
| • Observe the technical data provided here and refer to the documents listed under “Downloads”. The download area contains important information, such as installation notes, technical drawings, and 3D data. | |
| • The cable entry funnel is not safe to touch. Never connect or disconnect the terminal when it is energized. Take appropriate steps to ensure touch protection. | |
| • To maintain the nominal voltage, align the cable lugs straight and centered, and cast the terminals on the inside. | |
| Dimensional drawing | ![]() |
| Pitch | 25 mm |
| Título: | Tamanho: | Tipo: |
|---|---|---|
| PDF CATALOG PHOENIX PCB CONNECTORS EN.pdf | 27 Mbytes |
|
Não há comentários do produto ainda.
| Avaliação: |
|
| Nome: | |
| Email: | |
| Título: | |
| Opinión: | |
| Você recomendaria esse produto para comprar? | |
|
|
|
| Adicionar avaliação | |
Todas as classificações que recebemos a partir dos itens que oferecemos são reais e verificadas. Um pequeno gesto, mas muito valioso. Então, obrigado por esse minuto você gasta em deixar-nos a sua opinião e classificação de produtos, porque nos ajuda a continuar a melhorar e oferecer maior qualidade de serviço.