PKZM0-1-SC 229832 XTPRSC001BC1NL EATON ELECTRIC Motor-protective circuit-breaker, 3p, Ir 0.63-1A, screw/spri.. Ver maior
As imagens são só a título ilustrativo. Por favor, consulte a ficha técnica.

PKZM0-1-SC 229832 XTPRSC001BC1NL EATON ELECTRIC Motor-protective circuit-breaker, 3p, Ir 0.63-1A, screw/spri..

PKZM0-1-SC

229832

XTPRSC001BC1NL

EATON-MOELLER

Motor-protective circuit-breaker, 3p, Ir=0.63-1A, screw/spring clamp connection

Interruptor de proteção do motor 3 polos Ir=0.63-1 A Conexão com

Disjuntor de proteção do motor, 3p, Ir=0.63-1A, conexão de parafuso/grampo de mola

Disjuntor de proteção do motor de acordo com IEC/EN60947, tamanho de 3 polos PKZM0, com sobrecarga ajustável e desconexão de curto-circuito não retardada, sensível a falhas de fase, parafuso e acessório de encaixe, com terminais de parafuso e gaiola de mola, dimensão de instalação da tampa 45 mm, tensão nominal de operação Ue 690V, grau de proteção IP20, à prova de dedos de acordo com VDE 0106 T. 100, acessórios: contato auxiliar, liberação de tensão, módulo de contato, placa de clipe

Mais detalhes


Aparelhos elétricos de baixa tensão > Disjuntor de proteção do motor

Chaves de proteção do motor

Produto novo em sua embalagem original com todas as garantias e certificações de EATON-MOELLER

* Este artigo pode estar obsoleto. Se você estiver interessado, insira seu e-mail e informaremos se há unidades disponíveis. Caso não existam mais, um dos nossos técnicos procurará uma alternativa fornecivel com características semelhantes.

Se o nosso preço não é o melhor, peça-nos uma cotação Solicitar uma cotação

Related products

Best sellers

Mais informação



General specifications

Product Name
Eaton Moeller® series PKZM0 Motor-protective circuit-breaker
Catalog Number
229832
EAN
4015082298326
Product Length/Depth
76 mm
Product Height
93 mm
Product Width
45 mm
Product Weight
0.243 kg
Compliances
CE Marked
Certifications
IEC 60947-4-1
UL 508
CSA Std. C22.2 No. 14
VDE
UL File No.: E36332
CSA Class No.: 3211-05
CSA
CSA-C22.2 No. 60947-4-1-14
VDE 0660
UL 60947-4-1
UL Category Control No.: NLRV
CSA File No.: 165628
IEC/EN 60947
UL
CE
IEC/EN 60947-4-1
Catalog Notes
This item can only be ordered until December 31, 2023 with a maximum delivery date of May 31, 2024.
Model Code
PKZM0-1-SC

Funcionalidades e Funções

Actuator type
Turn button
Features
Phase-failure sensitivity (according to IEC/EN 60947-4-1, VDE 0660 Part 102)
Functions
Motor protection
Phase failure sensitive
Number of poles
Three-pole

Geral

Connection
Screw terminals on feed side
Spring-cage terminals on output side
Explosion safety category for dust
ATEX dust-ex-protection, PTB 10, ATEX 3013, Ex II(2) GD
Lifespan, electrical
100,000 operations (at 400V, AC-3)
Lifespan, mechanical
100,000 Operations (Main conducting paths)
Mounting position
Can be snapped on to IEC/EN 60715 top-hat rail with 7.5 or 15 mm height.
Operating frequency
40 Operations/h
Overvoltage category
III
Pollution degree
3
Product category
Motor protective circuit breaker
Protection
Finger and back-of-hand proof, Protection against direct contact when actuated from front (EN 50274)
Rated impulse withstand voltage (Uimp)
6000 V AC
Shock resistance
25 g, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
Suitable for
Also motors with efficiency class IE3
Branch circuit: Manual type E if used with terminal, or suitable for group installations, (UL/CSA)
Temperature compensation
-25 - 55 °C, Operating range
-5 - 40 °C to IEC/EN 60947, VDE 0660
≤ 0.25 %/K, residual error for T > 40°

Condições meteorológicas

Altitude
Max. 2000 m
Ambient operating temperature - min
-25 °C
Ambient operating temperature - max
55 °C
Ambient operating temperature (enclosed) - min
-25 °C
Ambient operating temperature (enclosed) - max
40 °C
Ambient storage temperature - min
-40 °C
Ambient storage temperature - max
80 °C
Climatic proofing
Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30

Capacidades dos terminais

Terminal capacity (flexible)
1 x (0.75 - 2.5) mm², ferrule to DIN 46228, Spring-loaded terminals
2 x (0.75 - 2.5) mm², ferrule to DIN 46228, Spring-loaded terminals
Terminal capacity (solid)
1 x (0.75 - 2.5) mm², Spring-loaded terminals
2 x (0.75 - 2.5) mm², Spring-loaded terminals
Terminal capacity (solid/stranded AWG)
18 - 14
Stripping length (main cable)
10 mm
Tightening torque
1.7 Nm, Screw terminals, Main cable
1 Nm, Screw terminals, Control circuit cables

Classificação elétrica

Rated frequency - min
50 Hz
Rated frequency - max
60 Hz
Rated operational current (Ie)
1 A
Rated operational power at AC-3, 220/230 V, 50 Hz
0.12 kW
Rated operational power at AC-3, 380/400 V, 50 Hz
0.25 kW
Rated operational voltage (Ue) - min
690 V
Rated operational voltage (Ue) - max
690 V
Rated uninterrupted current (Iu)
1 A

Classificação de curto-circuito

Short-circuit current
60 kA DC, up to 250 V DC, Main conducting paths
Short-circuit current rating (group protection)
600 A, 600 V High Fault, max. CB, SCCR (UL/CSA)
600 A, 600 V High Fault, max. Fuse, SCCR (UL/CSA)
50 kA, 600 V High Fault, Fuse, SCCR (UL/CSA)
50 kA, 600 V High Fault, CB, SCCR (UL/CSA)
Short-circuit current rating (type E)
Accessories required BK25/3-PKZ0-E
65 kA, 240 V, SCCR (UL/CSA)
65 kA, 480 Y/277 V, SCCR (UL/CSA)
50 kA, 600 Y/347 V, SCCR (UL/CSA)
Short-circuit release
Basic device fixed 15.5 x Iu, Trip Blocks
15.5 A, Irm, Setting range max.
± 20% tolerance, Trip blocks
Rated short-circuit breaking capacity Icu at 400 V AC
150 kA

Blocos de disparo

Overload release current setting - min
0.63 A
Overload release current setting - max
1 A
Tripping characteristic
Overload trigger: tripping class 10 A

Verificação do design

Equipment heat dissipation, current-dependent Pvid
5.33 W
Heat dissipation capacity Pdiss
0 W
Heat dissipation per pole, current-dependent Pvid
1.78 W
Rated operational current for specified heat dissipation (In)
1 A
Static heat dissipation, non-current-dependent Pvs
0 W
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

ETIM for 229832 Componentes industriais para Baixa Tensão (EC000074)
Característica Valor
Configuração de corrente da proteção contra sobrecargas (EF002336) 0.63 A
Faixa de ajuste da disparo em curto-circuito não retardada (EF007131) 15.5 A
Com proteção térmica (EF006233) Não
Sensível à falha de fase (EF007400) Sim
Técnica de disparo (EF007007) Termomagnético
Tensão nominal de operação (EF001435) 690 V
Corrente permanente nominal Iu (EF001389) 1 A
Potência de operação nominal em AC-3, 230 V (EF007025) 0.12 kW
Potência de operação nominal em AC-3, 400 V (EF001364) 0.25 kW
Potência dissipada (EF005387) 5.33 W
Tipo de conexão elétrica do circuito principal (EF006819) Ligação com parafuso
Tipo de elemento de controlo (EF006976) Botão rotativo
Construção do dispositivo (EF008240) Técnica de instalação fixa para dispositivo embutido
Com interruptor auxiliar integrado (EF001387) Não
Com passagem de subtensão integrada (EF001390) Não
Número de polos (EF001391) 3
Capacidade de interrupção nominal de curto-circuito Icu a 400 V, CA (EF007049) 150 kA
Grau de proteção (IP) (EF005474) IP20
Altura (EF000040) 93 mm
Largura (EF000008) 45 mm
Profundidade (EF000049) 76 mm

Datasheet - PDF

Avaliações: (0)

Não há comentários do produto ainda.

Adicionar avaliação
ocultar formulário
Avaliação:
Nome:
Email:
Título:
Opinión:
  Captcha
  Adicionar avaliação

Todas as classificações que recebemos a partir dos itens que oferecemos são reais e verificadas. Um pequeno gesto, mas muito valioso. Então, obrigado por esse minuto você gasta em deixar-nos a sua opinião e classificação de produtos, porque nos ajuda a continuar a melhorar e oferecer maior qualidade de serviço.