Magnetotermico 2p 2A 6kA curva C pLS6-C2 / 2
Disjuntor interno, 6kA, 2P, curva C, 2A
Eaton Moeller series xPole - PLS6/M MCB. PLS6, 2-pole, tripping characteristic: C, rated current In: 2 A, rated switching capacity IEC/EN 60898-1: 6 kA
Disjuntores, fusíveis > Interruptor magnetotérmico
Switchgear residencial modular
Produto novo em sua embalagem original com todas as garantias e certificações de EATON-MOELLER
Obrigado pelo seu interesse nos nossos artigos, esperamos que o prazo indicado seja conveniente para si.
Durante a preparação do pedido pode seleccionar o tipo de envío que melhor se adapte ás suas necessidades: Aéreo Express 24Hrs, Terrestre Standard 48/72Hrs, etc.
| Product Name | Eaton Moeller series xPole - PLS6/M MCB |
| Catalog Number | 242868 |
| EAN | 4015082428686 |
| Product Length/Depth | 85 mm |
| Product Height | 73 mm |
| Product Width | 35 mm |
| Product Weight | 0.24 kg |
| Compliances | RoHS conform |
| Certifications | CE |
| Model Code | PLS6-C2/2-MW |
| Used with | Miniature circuit breaker PLS6 |
| Amperage Rating | 2 A |
| Features | Additional equipment possible |
| 10.10 Temperature rise | The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. |
| 10.11 Short-circuit rating | Is the panel builder's responsibility. The specifications for the switchgear must be observed. |
| 10.12 Electromagnetic compatibility | Is the panel builder's responsibility. The specifications for the switchgear must be observed. |
| 10.13 Mechanical function | The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
| 10.2.2 Corrosion resistance | Meets the product standard's requirements. |
| 10.2.3.1 Verification of thermal stability of enclosures | Meets the product standard's requirements. |
| 10.2.3.2 Verification of resistance of insulating materials to normal heat | Meets the product standard's requirements. |
| 10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects | Meets the product standard's requirements. |
| 10.2.4 Resistance to ultra-violet (UV) radiation | Meets the product standard's requirements. |
| 10.2.5 Lifting | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.2.6 Mechanical impact | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.2.7 Inscriptions | Meets the product standard's requirements. |
| 10.3 Degree of protection of assemblies | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.4 Clearances and creepage distances | Meets the product standard's requirements. |
| 10.5 Protection against electric shock | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.6 Incorporation of switching devices and components | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.7 Internal electrical circuits and connections | Is the panel builder's responsibility. |
| 10.8 Connections for external conductors | Is the panel builder's responsibility. |
| 10.9.2 Power-frequency electric strength | Is the panel builder's responsibility. |
| 10.9.3 Impulse withstand voltage | Is the panel builder's responsibility. |
| 10.9.4 Testing of enclosures made of insulating material | Is the panel builder's responsibility. |
| Pollution degree | 2 |
| Degree of protection | IP20 |
| Equipment heat dissipation, current-dependent | 2.8 W |
| Rated impulse withstand voltage (Uimp) | 4 kV |
| Tripping characteristic | C |
| Ambient operating temperature - max | 75 °C |
| Ambient operating temperature - min | -25 °C |
| Built-in depth | 70.5 mm |
| Connectable conductor cross section (multi-wired) - max | 25 mm² |
| Connectable conductor cross section (multi-wired) - min | 1 mm² |
| Connectable conductor cross section (solid-core) - max | 25 mm² |
| Connectable conductor cross section (solid-core) - min | 1 mm² |
| Current limiting class | 3 |
| Frequency rating - max | 60 Hz |
| Frequency rating - min | 50 Hz |
| Heat dissipation capacity | 0 W |
| Heat dissipation per pole, current-dependent | 0 W |
| Width in number of modular spacings | 2 |
| Voltage type | AC |
| Overvoltage category | III |
| Number of poles | Two-pole |
| Release characteristic | C |
| Type |
|
| Special features | Ambient temperature hint: a 1 °C increase results in a 0.5% linear reduction of current carrying capacity |
| Application |
|
| Number of poles (protected) | 2 |
| Number of poles (total) | 2 |
| Rated insulation voltage (Ui) | 440 V |
| Rated operational current for specified heat dissipation (In) | 2 A |
| Rated operational voltage (Ue) - max | 400 V |
| Rated short-circuit breaking capacity (IEC/EN 60898-1) - Icn at 230 V | 6 kA |
| Rated short-circuit breaking capacity (IEC/EN 60898-1)- Icn at 400 V | 6 kA |
| Rated short-circuit breaking capacity (IEC 60947-2)- Icu at 230 V | 0 kA |
| Rated short-circuit breaking capacity (IEC 60947-2)- Icu at 400 V | 0 kA |
| Rated switching capacity (IEC/EN 60898-1) | 6 kA |
| Static heat dissipation, non-current-dependent | 0 W |
| Título: | Tamanho: | Tipo: |
|---|---|---|
| PDF EATON XEFFECT SWITCHGEAR RANGE EN.pdf | 8 Mbytes |
|
| PDF CATALOGUE EATON EN .pdf | 38 Mbytes |
|
| PLS6-C2/2-MW 242868 PT_242868.pdf | 83 Kbytes |
![]() |
Não há comentários do produto ainda.
| Avaliação: |
|
| Nome: | |
| Email: | |
| Título: | |
| Opinión: | |
| Você recomendaria esse produto para comprar? | |
|
|
|
| Adicionar avaliação | |
Todas as classificações que recebemos a partir dos itens que oferecemos são reais e verificadas. Um pequeno gesto, mas muito valioso. Então, obrigado por esse minuto você gasta em deixar-nos a sua opinião e classificação de produtos, porque nos ajuda a continuar a melhorar e oferecer maior qualidade de serviço.